The aggregation of electric vehicles (EVs) can take full advantage of the power flexibility of EV clusters, based on the aggregation feasible region (AFR) of EVs. However, existing aggregation techniques of conventional distributed energy resources (DERs), exhibit significant inaccuracies or require excessive computational efforts when applied to EVs with high power and small capacity. To solve this problem, an iterative method based on the high dimensional polyhedron projection principle is proposed to derive the exact AFR formula for the full power spectrum of EVs, and the limitations of the existing analytical AFR are revealed. The results reveal that the exact AFR is a set of linear inequalities, whose coefficients can be represented in binary code, and the complexity of the right side is linear with the number of EVs, making it highly conducive to programming calculations. Moreover, this paper proposes a simplified practical AFR based on the exact AFR, which reduces computational complexity. Numerical simulation cases demonstrate that the accuracy of this simplified approach is still higher than that of existing methods.
With the rapid development of wind turbines and rising penetration levels, grid codes now require wind farms to provide active frequency support. However, time delays in fast power response reduce the stability of system frequency modulation. This study focuses on integrated inertia control and droop control of wind turbines with explicit consideration of time delays. First, the frequency modulation process is analyzed, and the main sources of time delay are identified. A system frequency response model is then developed, incorporating the time delay link into the state-space equations. Based on this model, frequency-domain and linear matrix inequality methods are applied to analyze delay-independent stability and time delay margins of wind turbines. A PI controller for the synchronous unit is designed, and compensation parameters for wind turbine delay are calculated to enhance system stability. Simulation results show that with a wind penetration level of 50%, the system becomes unstable when the delay reaches 0.32 s. By applying the proposed strategy, stability can be maintained even with a delay of 0.5 s. These results confirm the effectiveness of the proposed strategy and highlight its potential for improving frequency regulation in high-renewable power systems.
Reliability assessment of power systems is essential for ensuring the secure and stable operation of power grids, and identifying weak links constitutes a critical step in enhancing system reliability. Traditional deterministic methods are limited in their ability to capture the complex, nonlinear relationships between component failures and overall system risk. To overcome this limitation, this paper proposes an explainable machine learning-based approach for identifying weak components in power systems. Specifically, a set of contingency scenarios is constructed through enumeration, and a random forest regression model is trained to map transmission line outage events to the amount of system load curtailment. The trained model is then interpreted using SHapley Additive exPlanations (SHAP) values. By aggregating these values, the global reliability contribution of each component is quantified. The proposed method is validated on the IEEE 57-bus system, and the results demonstrate its effectiveness and feasibility. This research offers a data-driven framework for translating system-level reliability metrics into device-level quantitative attributions, thereby enabling interpretable identification of weak links.
Islanded microgrids face significant frequency stability challenges due to limited system capacity, low inertia levels, and the strong variability in renewable energy sources. Traditional reliability assessment methods, often based on static power balance, struggle to comprehensively reflect frequency dynamic characteristics and their impact on power supply reliability. To address this issue, this paper proposes a sequential Monte Carlo reliability assessment method integrated with a system frequency response model. First, an SFR model for the isolated microgrid, incorporating diesel generators, gas turbines, energy storage, and wind turbines, is established. For synchronous units, a frequency deviation-based failure rate correction mechanism is introduced to characterize the impact of frequency fluctuations on equipment reliability. State transitions are achieved by integrating failure and repair rates to reach threshold values. Second, sequential Monte Carlo simulation is employed to conduct time-series simulations of annual operation. Random sampling of unit failure and repair times is used to calculate reliability metrics. MATLAB/Simulink simulation results demonstrate that system frequency fluctuations caused by power imbalance worsen unit failure rates, leading to microgrid reliability values lower than static calculations. This provides reference for planning, design, and operational scheduling of isolated microgrids.
18 August 2025 in International Journal of High Speed Electronics and Systems
With the spread of electric vehicles (EVs), the EV load will have a significant impact on the planning and operation of the grid and the operation of the electricity market. Due to the charging and discharging characteristics of EVs, as well as their randomness and dispersion, it is feasible and challenging to introduce EV loads into the grid as a means of frequency regulation and peak shaving of the power system. In this paper, considering multi-subject distribution networks and the interaction of source–grid–load–storage with Intelligent Transportation Systems (ITS), a density peak clustering (DPC) algorithm based on principal component analysis is employed to analyze the spatial and temporal characteristics of EV loads and identify the access status of EV charging stations and EV load status in each region in real time, as well as analyze the adjustable capacity and adjustable range of EV loads. Based on the adjustable capacity of the EV load, the optimization objectives include the maximum regulation of the EV load and the most economical operation cost. An accurate load regulation strategy based on automatic active control (APC) is proposed to reduce the maximum frequency deviation by 25% by integrating the load regulation of electric vehicles into the original AGC frequency regulation. At the same time, the feasibility of electric vehicles in peaking and standby scenarios is studied and verified through simulation cases, which can reduce the peak value of thermal power generation by 15% and 10% in the morning and evening.