Sofia I Hernandez Torres

Ms. Sofia I Hernandez Torres


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
EBEmily N. Boice
Emily N. Boice
STSofia I Hernandez Torres
Sofia I Hernandez Torres
ZKZechariah J. Knowlton
Zechariah J. Knowlton
DBDavid Berard
David Berard
JGJose Manuel Gonzalez
Jose Manuel Gonzalez
ESEric Joseph Snider
Eric Joseph Snider
Ultrasound (US) imaging is a critical tool in emergency and military medicine because of its portability and immediate nature. However, proper image interpretation requires skill, limiting its utility in remote applications for conditions such as pneumothorax (PTX) which requires rapid intervention. Artificial intelligence has the potential to automate ultrasound image analysis for various pathophysiological conditions. Training models require large data sets and a means of troubleshooting in real-time for ultrasound integration deployment, and they also require large animal models or clinical testing. Here, we detail the development of a dynamic synthetic tissue phantom model for PTX and its use in training image classification algorithms. The model comprises a synthetic gelatin phantom cast in a custom 3D-printed rib mold and a lung mimicking phantom. When compared to PTX images acquired in swine, images from the phantom were similar in both PTX negative and positive mimicking scenarios. We then used a deep learning image classification algorithm, which we previously developed for shrapnel detection, to accurately predict the presence of PTX in swine images by only training on phantom image sets, highlighting the utility for a tissue phantom for AI applications.

Verified
Journal Article
Open access
PDF file
GAGuy Avital
Guy Avital
ESEric Joseph Snider
Eric Joseph Snider
DBDavid Berard
David Berard
SVSaul J. Vega
Saul J. Vega
STSofia I Hernandez Torres
Sofia I Hernandez Torres
EBEmily N. Boice
Emily N. Boice
Physiological Closed-Loop Controlled systems continue to take a growing part in clinical practice, offering possibilities of providing more accurate, goal-directed care while reducing clinicians’ cognitive and task load. These systems also provide a standardized approach for the clinical management of the patient, leading to a reduction in care variability across multiple dimensions. For fluid management and administration, the advantages of closed-loop technology are clear, especially in conditions that require precise care to improve outcomes, such as peri-operative care, trauma, and acute burn care. Controller design varies from simplistic to complex designs, based on detailed physiological models and adaptive properties that account for inter-patient and intra-patient variability; their maturity level ranges from theoretical models tested in silico to commercially available, FDA-approved products. This comprehensive scoping review was conducted in order to assess the current technological landscape of this field, describe the systems currently available or under development, and suggest further advancements that may unfold in the coming years. Ten distinct systems were identified and discussed.

23 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
ESEric Joseph Snider
Eric Joseph Snider
STSofia I Hernandez Torres
Sofia I Hernandez Torres
RHRyan Hennessey
Ryan Hennessey
Deep learning predictive models have the potential to simplify and automate medical imaging diagnostics by lowering the skill threshold for image interpretation. However, this requires predictive models that are generalized to handle subject variability as seen clinically. Here, we highlight methods to improve test accuracy of an image classifier model for shrapnel identification using tissue phantom image sets. Using a previously developed image classifier neural network—termed ShrapML—blind test accuracy was less than 70% and was variable depending on the training/test data setup, as determined by a leave one subject out (LOSO) holdout methodology. Introduction of affine transformations for image augmentation or MixUp methodologies to generate additional training sets improved model performance and overall accuracy improved to 75%. Further improvements were made by aggregating predictions across five LOSO holdouts. This was done by bagging confidences or predictions from all LOSOs or the top-3 LOSO confidence models for each image prediction. Top-3 LOSO confidence bagging performed best, with test accuracy improved to greater than 85% accuracy for two different blind tissue phantoms. This was confirmed by gradient-weighted class activation mapping to highlight that the image classifier was tracking shrapnel in the image sets. Overall, data augmentation and ensemble prediction approaches were suitable for creating more generalized predictive models for ultrasound image analysis, a critical step for real-time diagnostic deployment.

22 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RGRachel Gathright
Rachel Gathright
IMIsiah Mejia
Isiah Mejia
JGJose Manuel Gonzalez
Jose Manuel Gonzalez
STSofia I Hernandez Torres
Sofia I Hernandez Torres
DBDavid Berard
David Berard
ESEric Joseph Snider
Eric Joseph Snider
Prehospital medical care is a major challenge for both civilian and military situations as resources are limited, yet critical triage and treatment decisions must be rapidly made. Prehospital medicine is further complicated during mass casualty situations or remote applications that require more extensive medical treatments to be monitored. It is anticipated on the future battlefield where air superiority will be contested that prolonged field care will extend to as much 72 h in a prehospital environment. Traditional medical monitoring is not practical in these situations and, as such, wearable sensor technology may help support prehospital medicine. However, sensors alone are not sufficient in the prehospital setting where limited personnel without specialized medical training must make critical decisions based on physiological signals. Machine learning-based clinical decision support systems can instead be utilized to interpret these signals for diagnosing injuries, making triage decisions, or driving treatments. Here, we summarize the challenges of the prehospital medical setting and review wearable sensor technology suitability for this environment, including their use with medical decision support triage or treatment guidance options. Further, we discuss recommendations for wearable healthcare device development and medical decision support technology to better support the prehospital medical setting. With further design improvement and integration with decision support tools, wearable healthcare devices have the potential to simplify and improve medical care in the challenging prehospital environment.

18 April 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
STSofia I Hernandez Torres
Sofia I Hernandez Torres
ARAustin Ruiz
Austin Ruiz
LHLawrence Holland
Lawrence Holland
RORyan Ortiz
Ryan Ortiz
ESEric Joseph Snider
Eric Joseph Snider
Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

20 May 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
EBEmily N. Boice
Emily N. Boice
STSofia I Hernandez Torres
Sofia I Hernandez Torres
ESEric Joseph Snider
Eric Joseph Snider
Ultrasound imaging is essential in emergency medicine and combat casualty care, oftentimes used as a critical triage tool. However, identifying injuries, such as shrapnel embedded in tissue or a pneumothorax, can be challenging without extensive ultrasonography training, which may not be available in prolonged field care or emergency medicine scenarios. Artificial intelligence can simplify this by automating image interpretation but only if it can be deployed for use in real time. We previously developed a deep learning neural network model specifically designed to identify shrapnel in ultrasound images, termed ShrapML. Here, we expand on that work to further optimize the model and compare its performance to that of conventional models trained on the ImageNet database, such as ResNet50. Through Bayesian optimization, the model’s parameters were further refined, resulting in an F1 score of 0.98. We compared the proposed model to four conventional models: DarkNet-19, GoogleNet, MobileNetv2, and SqueezeNet which were down-selected based on speed and testing accuracy. Although MobileNetv2 achieved a higher accuracy than ShrapML, there was a tradeoff between accuracy and speed, with ShrapML being 10× faster than MobileNetv2. In conclusion, real-time deployment of algorithms such as ShrapML can reduce the cognitive load for medical providers in high-stress emergency or miliary medicine scenarios.