Chris Ryan Seymour

Mr. Chris Ryan Seymour

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2025 in Water
Verified
Journal Article
Open access
PDF file
CGChristian Good
Christian Good
AWAlistair White
Alistair White
João BrandãoJoão Brandão
João Brandão
CSChris Ryan Seymour
Chris Ryan Seymour
SJSimon Jackson
Simon Jackson
We have used a rapid, portable assay (Bacterisk) to determine the bacterial water quality along several inland waters in SW England. Water samples were compared by a conventional membrane filter and culture methods for faecal indicator bacteria (FIB; E. coli and enterococci) and endotoxin measurement by Bacterisk. The Bacterisk data, measured in near-real-time, correlate well with both E. coli and enterococci, but also allow the presence of potential pathogens of a non-faecal origin to be detected. The sensitivity was calculated to be 92.96% with a specificity of 46.3% for E. coli with an expanded uncertainty of 22.07% and an Endotoxin Risk detection limit of 25 units. The presence of Bacterisk detectable non-faecal pathogenic bacteria in the water samples was successfully confirmed by Illumina MiSeq sequencing followed by target species-specific qPCR. Sequencing showed the presence of pathogens including Pseudomonas aeruginosa, Salmonella typhi, Acinetobacter baumannii, Shigella spp., and Legionella spp. as well as antimicrobial resistance genes. Furthermore, the portable Bacterisk assay was able to acquire data on the water quality from different locations and at different time points, providing a comprehensive surveillance tool that challenges the time to results by conventional methods (minutes instead of days), yielding compatible results.

10 April 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SJSimon Jackson
Simon Jackson
CGChristian Good
Christian Good
AWAlistair White
Alistair White
CSChris Ryan Seymour
Chris Ryan Seymour
João BrandãoJoão Brandão
João Brandão
We have used a rapid, portable assay (Bacterisk) to determine bacterial water quality along several inland waters in SW England. Water samples were compared by conventional membrane filter and culture methods for faecal indicator bacteria (FIB; E. coli and enterococci) and endotoxin measurement by Bacterisk. The Bacterisk data, measured in near real-time, correlates well with both E. coli and enterococci, but also allowed the presence of potential pathogens of non-faecal origin to be detected. The sensitivity was calculated to be 92.96% with a specificity of 46.3% for E. coliwith an expanded uncertainty of 22.07% and an Endotoxin Risk detection limit of 25 units. The presence of Bacterisk detectable non-faecal pathogenic bacteria in the water samples was successfully confirmed by Illumina MiSeq sequencing followed by target species-specific qPCR. Sequencing showed the presence of pathogens including Pseudomonas aeruginosa, Salmonella typhi, Acinetobacter baumannii, Shigella spp, Legionella spp as well as antimicrobial resistance genes. Furthermore, the portable Bacterisk assay was able to acquire data on water quality from different locations and at different time points providing a comprehensive surveillance tool that challenges the time to results by conventional methods (minutes instead of days), yielding compatible results.