Kacper Ruzik

Dr. Kacper Ruzik


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ŁOŁukasz Olewnik
Łukasz Olewnik
ILIngrid C. Landfald
Ingrid C. Landfald
BGBartosz Gonera
Bartosz Gonera
ŁGŁukasz Gołek
Łukasz Gołek
KRKacper Ruzik
Kacper Ruzik
RLRobert LaPrade
Robert LaPrade
The popliteofibular ligament (PFL) plays a vital role in knee joint stability, particularly within the posterolateral corner (PLC) of the knee. Located between the femoral condyle and the fibular head, the PFL resists excessive external rotation and lateral translation of the tibia, thus preventing knee instability during dynamic activities. This ligament, although integral in maintaining knee integrity, has often been overlooked in clinical practice and research. This review synthesizes the current literature on the anatomy, biomechanics, and clinical relevance of the PFL, highlighting its morphological variations, functional significance, and implications for knee injuries, particularly in relation to PLC trauma. Anatomical studies have identified significant variations in the PFL’s structure, including single, bifurcated, and double ligament forms, each influencing the ligament’s mechanical properties and its susceptibility to injury. Additionally, the PFL’s interaction with other knee structures, such as the fibular collateral ligament and popliteus tendon, is crucial for resisting rotational and translational forces, especially during high-stress movements like pivoting and cutting. Injuries to the PFL, often occurring in conjunction with other PLC structures, can lead to chronic knee instability and require precise diagnostic techniques, including MRI and ultrasound, for accurate assessment. Surgical management, including PFL reconstruction, has shown promising results in restoring knee stability, especially when tailored to the patient’s anatomical variant. This review provides a comprehensive understanding of the PFL’s role in knee function and its clinical implications, emphasizing the need for individualized treatment strategies in knee reconstruction

Verified
Journal Article
Open access
PDF file
MPMarta Pośnik
Marta Pośnik
AWAndrzej Węgiel
Andrzej Węgiel
NZNicol Zielinska
Nicol Zielinska
KRKacper Ruzik
Kacper Ruzik
ŁOŁukasz Olewnik
Łukasz Olewnik
MPMichał Podgórski
Michał Podgórski
Background: The muscles and their tendons exhibit considerable morphological variations. While the anterior leg compartment may seem uniform, several well-documented variants of the tibialis anterior, extensor hallucis longus (EHL) and extensor digitorum longus (EDL) exist. In contrast, little is known about the fibularis tertius muscle (FT). This literature review aims to compile existing data on the FT and its variations and assess this structure’s clinical significance. Material and Methods: This comprehensive literature review is based on scientific articles obtained from PubMed. All relevant papers were included, and citation tracking was conducted to ensure a thorough examination of the topic. Results: This detailed literature review synthesizes the latest scientific findings regarding the FT, exploring its variable morphology, functional anatomy, evolutionary significance and clinical relevance. A high morphological variability of the FT is described including its origin, insertion and accessory form. Nevertheless, the FT has been described in cadaveric studies between adults and fetuses, while few classification systems have been proposed. Conclusions: The FT is an intriguing structure that has garnered interest from researchers across various fields, including medicine, clinical practice and biological sciences. There are few clinical implications of the muscle such as FT syndrome or tendon tear. Adequate knowledge of its anatomy is of paramount importance for clinicians.

10 June 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
PŁPiotr Cezary Łabętowicz
Piotr Cezary Łabętowicz
NZNicol Zielinska
Nicol Zielinska
DPDawid Pilewski
Dawid Pilewski
ŁOŁukasz Olewnik
Łukasz Olewnik
KRKacper Ruzik
Kacper Ruzik
Background: The femoral artery is a continuation of the external iliac artery. Knowledge of the topography and morphological variability of the thigh vessels informs various fields of medicine, such as hip replacement, hip fracture and femoral trochanter fracture, embolectomy, and angiography. The main aim of this study was to calculate the δ index from morphological measurements. We introduce the δ index to quantify the relative dominance of the DFA in supplying the thigh, aiming to improve clinical assessment and procedural planning. Methods: The study comprised two parts: anatomical dissection and radiological examination. During the anatomical study, 80 lower limbs (34 female and 46 male) fixed in 10% formalin were dissected. For the radiological study, angio-CT scans of the lower limbs of 100 patients (200 lower limbs) were analyzed. In both studies, the δ index was determined. This is the ratio of the diameter of the deep femoral artery at its point of origin to the diameter of the femoral artery after that origin. The morphometric measurements were analyzed statistically using Statistica 12.0 software. Results: The average values of the δ index for the right side were 0.95 (±0.23) and 0.89 (±0.21), respectively, in the anatomical and radiological studies, while for the left side they were 0.94 (±0.23) and 0.89 (±0.27), respectively. The average values for males were 0.88 (±0.18) and 0.80 (±0.17), respectively, while for females they were 1.04 (±0.26) and 1.12 (±0.23), respectively. Conclusions: The δ index, elaborated and calculated in anatomical and radiological studies, showed no statistically significant body side difference. However, it showed a statistically significant sex difference; there was a greater distribution of blood through the deep femoral artery in women than in men.

4 August 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ŁOŁukasz Olewnik
Łukasz Olewnik
ILIngrid C. Landfald
Ingrid C. Landfald
BGBartosz Gonera
Bartosz Gonera
ŁGŁukasz Gołek
Łukasz Gołek
ASAleksandra Szabert-Kajkowska
Aleksandra Szabert-Kajkowska
KRKacper Ruzik
Kacper Ruzik
Background: Midportion Achilles tendinopathy (Mid-AT) is a complex condition that may be exacerbated by anatomical variations of the plantaris tendon. Recent anatomical studies, particularly the classification proposed by Olewnik et al., have enhanced the understanding of plantaris–Achilles interactions and their clinical implications. Objective: This review aims to assess the anatomical types of the plantaris tendon, their imaging correlates, and the impact of the Olewnik classification on diagnosis, treatment planning, and surgical outcomes in patients with Mid-AT. Methods: We present an evidence-based analysis of the six anatomical types of the plantaris tendon and their relevance to Achilles tendinopathy, with emphasis on MRI and ultrasound (USG) evaluation. A diagnostic and therapeutic algorithm is proposed, and clinical outcomes of both conservative and operative management are compared across tendon types. Results: Types I and V were most strongly associated with symptomatic conflict and showed the highest benefit from surgical resection. Endoscopic approaches were effective in Types II and III, while Type IV typically responded to conservative treatment. Type VI, often misdiagnosed as tarsal tunnel syndrome, required combined neurolysis. The classification significantly improves surgical decision-making, reduces overtreatment, and enhances diagnostic precision. Conclusions: The Olewnik classification provides a reproducible, clinically relevant framework for individualized management of Mid-AT. Its integration into imaging protocols and treatment algorithms may improve therapeutic outcomes and guide future research in orthopaedic tendon pathology.

18 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
MDMarek Drobniewski
Marek Drobniewski
BGBartosz Gonera
Bartosz Gonera
ŁOŁukasz Olewnik
Łukasz Olewnik
ABAdam Borowski
Adam Borowski
KRKacper Ruzik
Kacper Ruzik
ABAndrzej Borowski
Andrzej Borowski
Purpose: Revision total hip arthroplasty (RTHA) in the presence of a well-fixed femoral stem carries substantial risk and morbidity, as stem removal often leads to bone loss, prolonged operative time, and increased blood loss. This issue is particularly relevant for older implants featuring a 14/16 taper, which are no longer compatible with most modern femoral heads. The Bioball™ System (Merete Medical, Germany), a modular head–neck adapter, provides a solution that enables acetabular or head-only revision while preserving the existing femoral stem. This study aimed to evaluate the long-term clinical and radiological outcomes of revision THA procedures using the Bioball™ System in patients with 14/16 femoral tapers. Methods: This retrospective study analyzed 1039 RTHAs performed at our center between 2008 and 2020. 38 patients (23 women, 15 men; mean age 73.5 years) were finally included in the study. All procedures were performed in the presence of a well-fixed femoral stem with a 14/16 taper. Revisions were limited to exchange of the acetabular component, liner, or both using the Bioball™ System, thus avoiding femoral stem removal. The primary reason for revision surgery in the study group was acetabular cup loosening (n=29, 76.31%), while only the liner was replaced in 9 patients (23.69%). Clinical evaluation included the Merle d’Aubigné and Postel score (modified by Charnley), and radiological analysis assessed component fixation, migration, and signs of loosening. The mean follow-up period was 3082 days (8.44 years; SD 1041.5; Me 2872). Results: In 29 patients (76.3%), both the acetabular component and liner were replaced, while in 9 patients (23.7%) only the liner and head were exchanged. The most commonly used adapter lengths were 2XL (+10.5 mm, 28.95%), 5XL (+21 mm, 21.05%), 3XL (+14 mm, 18.42%), and 4XL (+17.5 mm, 15.79%); shorter sizes (M, L, XL) were applied less frequently. A 7.5° offset adapter was used in 57.9% of cases to optimize offset and anteversion, and 32 mm heads were employed in 71.05% of revisions. The modified Merle d’Aubigné and Postel (MAP) score improved by a mean of 5.7 points (p < 0.05), with good outcomes in 36.84% and fair in 63.16% of patients. Pain intensity on the VAS scale decreased from 7.4 to 2.6 (p < 0.05). Furthermore, until the final day of the follow-up period i.e. June 30, 2025, no signs of prosthesis loosening were noted in any of the patients included in the study. The Modified MAP score was distributed the same between the different procedure types (p=0.404). Conclusion: The Bioball™ System enables restoration of hip stability and offset without removing a well-fixed femoral stem, thereby reducing surgical invasiveness, blood loss, and procedure-related risks. It provides an effective solution for revisions involving older 14/16 tapers, where conventional 12/14 heads are incompatible, and demonstrates favorable long-term functional and radiological outcomes. Further studies are warranted to confirm its broader applicability in complex revision THA.

17 January 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MDMarek Drobniewski
Marek Drobniewski
BGBartosz Gonera
Bartosz Gonera
ŁOŁukasz Olewnik
Łukasz Olewnik
ABAdam Borowski
Adam Borowski
KRKacper Ruzik
Kacper Ruzik
ABAndrzej Borowski
Andrzej Borowski
Purpose: Revision total hip arthroplasty (RTHA) in the presence of a well-fixed femoral stem is associated with increased risk, as stem removal often results in bone loss, prolonged operative time, and greater blood loss. This problem is particularly relevant for older implants with a 14/16 taper, which is incompatible with most modern femoral heads. The Bioball™ System, a modular head–neck adapter, allows for acetabular or head-only revision while preserving the femoral stem. This study aimed to evaluate long-term clinical and radiological outcomes of RTHA using the Bioball™ System in patients with 14/16 tapers. Methods: A total of 38 patients (23 women, 15 men; mean age 73.5 years) met the inclusion criteria. All procedures were carried out with a well-fixed femoral stem and a 14/16 taper. Revisions were limited to exchange of the acetabular component, liner, or both, avoiding stem removal. The primary indication was acetabular cup loosening (n = 29, 76.3%); liner-only exchange was performed in 9 patients (23.7%). Clinical outcomes were assessed using the modified Merle d’Aubigné and Postel (MAP) score, and radiological evaluation focused on fixation, migration, and loosening. Mean follow-up was 8.44 years. Results: Both the acetabular component and liner were replaced in 76.3% of patients, while 23.7% underwent liner and head exchange only. Longer adapter sizes were most frequently used, and a 7.5° offset adapter was applied in 57.9% of cases. The modified MAP score improved by a mean of 5.7 points (p < 0.05), and VAS pain scores decreased from 7.4 to 2.6 (p < 0.05). No radiological signs of loosening were observed at final follow-up. Conclusions: The Bioball™ System enables effective restoration of hip stability and offset without femoral stem removal, offering favorable long-term clinical and radiological outcomes in revisions involving older 14/16 tapers.