Many scientific disciplines currently are experiencing a “reproducibility crisis” because numerous scientific findings cannot be repeated consistently. A novel but controversial hypothesis postulates that stringent levels of environmental and biotic standardization in experimental studies reduces reproducibility by amplifying impacts of lab-specific environmental factors not accounted for in study designs. A corollary to this hypothesis is that the deliberate introduction of controlled systematic variability (CSV) in experimental designs can increase reproducibility. We tested this hypothesis using a multi-laboratory microcosm study in which the same ecological experiment was repeated in 14 laboratories across Europe. Each laboratory introduced environmental and genotypic CSV within and among replicated microcosms established in either growth chambers (with stringent control of environmental conditions) or glasshouses (with more variable environmental conditions). The introduction of genotypic CSV led to lower among-laboratory variability in growth chambers, indicating increased reproducibility, but had no significant effect in glasshouses where reproducibility also was lower. Environmental CSV had little effect on reproducibility. Although there are multiple causes for the “reproducibility crisis”, deliberately including genetic variation may be a simple solution for increasing the reproducibility of ecological studies performed in controlled environments.
Biogenic volatile organic compounds (BVOCs) regulate key atmospheric and ecological processes but remain challenging to quantify in the field due to reactivity, mixture complexity, and variable ambient humidity. A portable fast Gas Chromatography-Mass Spectrometry (GC–MS) workflow was developed, coupling needle-trap (NT) sampling with a compact GC–MS system to enable BVOC quantification with minimal logistics. A 15-compound gas standard (28–91 µmol mol⁻¹) was generated under controlled water vapor pressures (ea = 0.7–2.3 kPa), and two independent calibrations sessions were performed to assess reproducibility. Seven compounds (α-pinene, benzene, chlorobenzene, 1,2-dichlorobenzene, isoprene, toluene, and o-xylene) exhibited linear responses (R² > 0.85) across humidity levels. Calibration sensitivity showed a strong exponential dependence on ea, and compound-specific correction functions were derived. Concentrations estimated from portable GC–MS showed excellent agreement with Proton Transfer Reaction Mass Spectrometry (PTR–MS) reference values (R² > 0.94). Six additional VOCs were detected but not reliably quantified under 3- min GC conditions. The method provides a 15- min sampling-to-result cycle and requires only 40 mL of air. The working limit of quantification was approximately 40 ppb, making the method primarily suited to chamber or enriched‑air applications where BVOC levels exceed this threshold. • Portable NT + fast GC–MS workflow for in-field BVOC quantification. • Humidity-dependent exponential sensitivity functions used for correction. • Good agreement with PTR–MS reference concentrations (R² > 0.94).