Ravi Naik

Mr. Ravi Naik

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2022 in Journal of Surgical Research
Verified
Journal Article
Open access
RNRavi Naik
Ravi Naik
AKAlexandros Kogkas
Alexandros Kogkas
HAHutan Ashrafian
Hutan Ashrafian
GMGeorge Mylonas
George Mylonas
ADAra Darzi
Ara Darzi
Increased cognitive workload (CWL) is a well-established entity that can impair surgical performance and increase the likelihood of surgical error. The use of pupil and gaze tracking data is increasingly being used to measure CWL objectively in surgery. The aim of this review is to summarize and synthesize the existing evidence that surrounds this. A systematic review was undertaken in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A search of OVID MEDLINE, IEEE Xplore, Web of Science, Google Scholar, APA PsychINFO, and EMBASE was conducted for articles published in English between 1990 and January 2021. In total, 6791 articles were screened and 32 full-text articles were selected based on the inclusion criteria. A narrative analysis was undertaken in view of the heterogeneity of studies. Seventy-eight percent of selected studies were deemed high quality. The most frequent surgical environment and task studied was surgical simulation (75%) and performance of laparoscopic skills (56%) respectively. The results demonstrated that the current literature can be broadly categorized into pupil, blink, and gaze metrics used in the assessment of CWL. These can be further categorized according to their use in the context of CWL: (1) direct measurement of CWL (n = 16), (2) determination of expertise level (n = 14), and (3) predictors of performance (n = 2). Eye-tracking data provide a wealth of information; however, there is marked study heterogeneity. Pupil diameter and gaze entropy demonstrate promise in CWL assessment. Future work will entail the use of artificial intelligence in the form of deep learning and the use of a multisensor platform to accurately measure CWL.

7 June 2024 in Annals of Surgery
Verified
Journal Article
Open access
AAAws Msc Almukhtar
Aws Msc Almukhtar
VCVirginia Mrcs Caddick
Virginia Mrcs Caddick
RNRavi Naik
Ravi Naik
MGMary MBChB Goble
Mary MBChB Goble
George MylonasGeorge Mylonas
George Mylonas
Daniel LeffDaniel Leff
Daniel Leff
Objective: To systematically review technologies that objectively measure cognitive workload (CWL) in surgery, assessing their psychometric and methodological characteristics. Background: Surgical tasks involving concurrent clinical decision-making and the safe application of technical and non-technical skills require a substantial cognitive demand and resource utilization. Cognitive overload leads to impaired clinical decision-making and performance decline. Assessing CWL could enable interventions to alleviate burden and improve patient safety. Methods: Ovid MEDLINE, OVID Embase, the Cochrane Library, and IEEE Xplore databases were searched from inception to August 2023. Full-text, peer-reviewed original studies in a population of surgeons, anesthesiologists or interventional radiologists were considered, with no publication date constraints. Study population, task paradigm, stressor, cognitive load theory (CLT) domain, objective and subjective parameters, statistical analysis, and results were extracted. Studies were assessed for (1) definition of CWL; (2) details of the clinical task paradigm; and (3) objective CWL assessment tool. Assessment tools were evaluated using psychometric and methodological characteristics. Results: A total of 10,790 studies were identified; 9004 were screened; 269 full studies were assessed for eligibility, of which 67 met inclusion criteria. The most widely used assessment modalities were autonomic (32 eye studies and 24 cardiac). Intrinsic workload (eg, task complexity) and germane workload (effect of training or expertize) were the most prevalent designs investigated. CWL was not defined in 30 of 67 studies (44.8%). Sensitivity was greatest for neurophysiological instruments (100% EEG, 80% fNIRS); and across modalities accuracy increased with multisensor recordings. Specificity was limited to cardiac and ocular metrics, and was found to be suboptimal (50% and 66.67%). Cardiac sensors were the least intrusive, with 54.2% of studies conducted in naturalistic clinical environments (higher ecological validity). Conclusions: Physiological metrics provide an accessible, objective assessment of CWL, but dependence on autonomic function negates selectivity and diagnosticity. Neurophysiological measures demonstrate favorable sensitivity, directly measuring brain activation as a correlate of cognitive state. Lacking an objective gold standard at present, we recommend the concurrent use of multimodal objective sensors and subjective tools for cross-validation. A theoretical and technical framework for objective assessment of CWL is required to overcome the heterogeneity of methodological reporting, data processing, and analysis.

5 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KJKaizhe Jin
Kaizhe Jin
ARAdrian Rubio-Solis
Adrian Rubio-Solis
RNRavi Naik
Ravi Naik
Daniel LeffDaniel Leff
Daniel Leff
JKJames Kinross
James Kinross
George MylonasGeorge Mylonas
George Mylonas
This systematic review analyses advancements in cognitive state recognition from 2010 to early 2024, evaluating 405 relevant articles from an initial pool of 2398 records identified through five databases: Scopus, Engineering Village, Web of Science, IEEE Xplore, and PubMed. Studies were included if they assessed cognitive states using physiological signals and applied machine learning (ML) or deep learning (DL) techniques in practical task settings. The review highlights a pivotal shift from shallow ML to DL approaches for analysing physiological signals, driven by DL’s ability to autonomously learn complex patterns in large datasets. By 2023, DL has become the dominant methodology, though traditional ML techniques remain relevant. Additionally, there has been a move from neuroimaging to multimodal physiological modalities, with the decrease in neuroimaging use reflecting a trend towards integrating various physiological signals for more comprehensive insights. Cognitive state recognition is applied across diverse domains such as the automotive, aviation, maritime, and healthcare industries, enhancing performance and safety in high-stakes environments. Electrocardiogram (ECG) is the most utilised modality, with convolutional neural networks (CNNs) being the primary DL approach. The trend in cognitive state recognition research is moving towards integrating ECG signals with CNNs and adopting privacy-preserving methodologies like differential privacy and federated learning, highlighting the potential of cognitive state recognition to enhance performance, safety, and innovation across various real-world applications.

26 August 2024 in International Journal of Surgery
Verified
Journal Article
Open access
BDBibek Das
Bibek Das
FLFrances Ledesma
Frances Ledesma
RNRavi Naik
Ravi Naik
SLSarah Law
Sarah Law
PSPayam Soleimani-Nouri
Payam Soleimani-Nouri
MFMatyas Fehervari
Matyas Fehervari
Introduction: The COVID-19 pandemic led to a significant reduction in operative exposure for surgical trainees, necessitating alternative training methods to mitigate the impact on surgical education. This study sought to evaluate whether minimally invasive surgery (MIS) skills could be taught remotely using widely available technology with objective assessments of proficiency. Methods: This was a pilot observational study with a comparative assessment of face-to-face (F2F) and virtual training of novice learners in MIS skills. Performance and objective cognitive workload parameters [Surgical Task Load Index (SURG-TLX) score, heart rate, and pupil metrics] were evaluated. The assessments were peg transfer [McGill Inanimate System for Training and Evaluation of Laparoscopic Skills (MISTELS)] and suturing [Suturing Training and Testing (SUTT)] tasks performed using box trainers. Virtual teaching was conducted by expert trainers using a web-based streaming platform. Results: Technical challenges of delivering a virtual MIS skills course were addressed after a pilot course. Participants (n=20) in the final course had similar baseline characteristics and were randomly allocated to F2F (n=8) and virtual (n=12) teaching groups. Participants in the online group completed the peg transfer task faster than the F2F group (11.25 min vs. 16.88 min; P=0.015). There were no significant differences in all other MISTELS and SUTT performance measures between groups. Cognitive workload parameters (SURG-TLX score, heart rate, and pupil metrics) were also similar between groups. Conclusion: This study has demonstrated that virtual teaching of MIS skills using a web-based streaming platform is feasible and effective, providing the foundation for low-cost, effective, and scalable MIS skills programs in the future.

15 October 2024 in European Journal of Surgical Oncology
Verified
Journal Article
Closed access
RNRavi Naik
Ravi Naik
ARAdrian Rubio-Solis
Adrian Rubio-Solis
KJKaizhe Jin
Kaizhe Jin
George MylonasGeorge Mylonas
George Mylonas

13 August 2024 in Global Surgical Education - Journal of the Association for Surgical Education
Verified
Journal Article
Open access
PDF file
RNRavi Naik
Ravi Naik
MFMatyas Fehervari
Matyas Fehervari
RARayyan Ali
Rayyan Ali
GHGeorge Hazell
George Hazell
TKTarek Kutaiman
Tarek Kutaiman
ADAra Darzi
Ara Darzi
Background: The study of cognitive load management in surgery has led to identification of objective cognitive workload (CWL) correlates offering the potential to improve patient safety, enhance surgeon performance and their long-term well-being. Sensors have been used in isolation within surgery to measure physiological changes of the surgeon to infer CWL. More recently however, the use of multimodal sensors (MMS) has been explored to improve the reliability of CWL measurement. Despite the emergence of this technology, the behavioural intention of future users of MMS is not well understood. The aim of this study is to explore the perceptions of CWL measurement using MMS in surgery and secondly, to develop a model of acceptance amongst a cohort of future users. Methods: A cross-sectional survey of medical students in the United Kingdom was undertaken by means of an online questionnaire based on the Unified Theory of Acceptance and Use of Technology (UTAUT) model, using performance expectancy (PE), effort expectancy (EE), social influence (SI), facilitating conditions (FC) and behavioural intention (BI) as latent constructs. A purposive sampling method was undertaken over a period of nine months. Results were analysed using structural equation modelling. Results: There were 232 responses with 138 fully completed responses used for final data analysis. Weighted averages of all item responses demonstrated positive responses to all questionnaire statements. Students strongly agreed to ‘Technology used to measure my mental workload would be useful to me’ (42.8%), ‘I would use the system if it was comfortable to wear’ (53.6%) and ‘I would like to know that the technology is reliable before using it’ (68.8%). Pathway co-efficients were 0.444 for PE → BI (p = < 0.001), 0.221 for EE → BI (p = < 0.001), 0.096 for SI → BI (p = 0.186) and 0.142 for FC → BI (p = 0.094). Conclusion: This study demonstrates an overall positive perception of CWL measurement using MMS. Although social influences and facilitating conditions demonstrate a positive influence on the behavioural intention of students, performance and effort expectancy are significant constructs to consider, namely the comfort and reliability of multimodal sensors. Findings from this study can be used to guide future development of emerging MMS systems that can be used to reduce human error, improve training and patient safety.