Shilin Liu

Shilin Liu


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2007 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
YYYuanqin Yu
Yuanqin Yu
KLKe Lin
Ke Lin
XZXiaoguo Zhou
Xiaoguo Zhou
HWHua Wang
Hua Wang
SLShilin Liu
Shilin Liu
XMXingxiao Ma
Xingxiao Ma

22 March 2010 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
HSHong‐Yan Shi
Hong‐Yan Shi
BHBo Hu
Bo Hu
XYXiao‐Chun Yu
Xiao‐Chun Yu
RZRong‐Li Zhao
Rong‐Li Zhao
XRXi-Feng Ren
Xi-Feng Ren
SYShu‐Hong Yu
Shu‐Hong Yu

23 February 2010 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
KLKe Lin
Ke Lin
XZXiaoguo Zhou
Xiaoguo Zhou
YLYi Luo
Yi Luo
SLShilin Liu
Shilin Liu

16 May 2013 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
YYYuanqin Yu
Yuanqin Yu
YWYuxi Wang
Yuxi Wang
KLKe Lin
Ke Lin
NHNaiyin Hu
Naiyin Hu
XZXiaoguo Zhou
Xiaoguo Zhou
SLShilin Liu
Shilin Liu

1 November 2009 in Review of Scientific Instruments
Verified
Journal Article
Closed access
XTXiaofeng Tang
Xiaofeng Tang
XZXiaoguo Zhou
Xiaoguo Zhou
MNMingli Niu
Mingli Niu
SLShilin Liu
Shilin Liu
JSJinda Sun
Jinda Sun
LSLiusi Sheng
Liusi Sheng
A novel threshold photoelectron-photoion coincidence (TPEPICO) imaging spectrometer at the U14-A beamline of the Hefei National Synchrotron Radiation Laboratory is presented. A set of open electron and ion lenses are utilized to map velocity imaging of photoelectrons and photoions simultaneously, in which a repelling electric field using an extra lens is applied to magnify images of photoelectrons instead of traditional accelerating electric field in order to suppress the contribution of energetic electrons in the threshold photoelectron spectroscopy (TPES) and the mass-selected TPEPICO spectroscopy. The typical energy resolution of TPES is measured to be 9 meV (full width at half maximum), as shown on the P21/2 ionization of argon. The measured mass resolving power for the present TPEPICO imaging spectrometer is above 900 of M/ΔM. Subsequently as a benchmark, oxygen molecule is photoionized by monochromatic synchrotron radiation at 20.298 eV and dissociates to an oxygen atomic ion and a neutral oxygen atom, and the translation energy distribution of oxygen atomic ion is measured by the time-sliced imaging based on mass-selected TPEPICO experiment. The kinetic energy resolution of the present ion velocity imaging is better than 3% of ΔE/E.

23 July 2012 in Small
Verified
Journal Article
Closed access
PDF file
CZChuanling Zhang
Chuanling Zhang
KLKong‐Peng Lv
Kong‐Peng Lv
NHNai‐Yin Hu
Nai‐Yin Hu
LYLe Yu
Le Yu
XRXi-Feng Ren
Xi-Feng Ren
SYShu‐Hong Yu
Shu‐Hong Yu