Presence and consequent extent of infection in patients on continuous-flow left ventricular assist devices (CF-LVADs) can be challenging with the current diagnostic tools. The present study sought to demonstrate the diagnostic power of 18F-Fluorodeoxyglucose-Positron-Emission Tomography/Computed Tomography (18F-FDG PET/CT) in detecting infection in patients supported with CF-LVAD. The present study sought to demonstrate the diagnostic power of 18F-fluorodeoxyglucose-positron-emission tomography/computed tomography (18F-FDG PET/CT) in detecting infection in patients supported with CF-LVAD. Between July 2009 and April 2016, 61 PET/CT examinations were performed in 47 patients (median age 64.13 years, IQR 18.77) supported with a CF-LVAD. PET/CT assessments were performed qualitatively and quantitatively at three different levels: at the piercing site of driveline (first level), along the intracorporeal course of driveline (second level), and around the device (third level). Final diagnosis of LVAD infection was prospectively performed and was based upon microbiological samples taken at hospital admission, during the surgical revision/transplantation and recurrence of symptoms on long-term follow-up. At last follow-up a total of 40 (65.57%) final diagnoses of LVAD-infection could be ascertained. Matching the final diagnosis with the PET/CT assessments the sensitivity, specificity, and positive and negative predictive value were 90.0, 71.4, 85.71, and 78.94%, respectively. Level sub-analyses of SUV max showed an optimal discriminator power for levels 1 and 2 (AUC of level 1—0.824, P < 0.001; AUC of level 2—0.849, P < 0.001, respectively). At the third level semi-quantitative analysis showed poor discriminator power (AUC 0.589, P = 0.33). Qualitative visual analysis instead indicated a trend toward significance (P = 0.07). Quantitative 18F-FDG PET/CT is an optimal diagnostic tool in detecting superficial and deep driveline infections. However, diagnostic accuracy with regard to the diagnosis of pump housing infection is limited. Here, clinical and qualitative PET/CT analyses must be better considered.
4 January 2012 in Interactive CardioVascular and Thoracic Surgery
Despite a more physiological morphology of atrial anastomosis in the bicaval technique with respect to standard biatrial anastomosis in orthotopic heart transplantation (OHT), the impact on the long-term outcome is still not clear. In this retrospective study, we sought to investigate the morphology and function of the atria through magnetic resonance imaging (MRI) and transthoracic echocardiography (TTE). Moreover, we aimed to analyse the accuracy of TTE with respect to MRI. Cox regression analysis of 216 consecutive patients receiving OHT between August 1987 and January 2010 identified only recipient age at the time of transplant to be an independent predictor of mortality (P = 0.048, odds ratio= 1.04). After a mean follow-up of 96.6 ± 77.7 months, 108 patients were alive, of which 35 were found to be eligible for MRI assessment. In this analysis, left and right atrial volumes were found to be significantly larger in the standard group in comparison with the bicaval group (P = 0.001), and no significant difference between the two techniques was observed in left and right atrio-ventricular output. Moreover, a significantly reduced accuracy was observed (CCC < 0.3) when TTE results were compared with MRI assessment in evaluating atrial dimensions. Although left and right atrial volumes are significantly larger in the standard group in comparison with the bicaval group, we concluded that no significant difference in the atrial output and survival between the two techniques could be demonstrated.
Perioperative myocardial ischemia (PMI) in patients undergoing coronary artery bypass grafting (CABG) is associated with poor outcome. The aim of this study was to pool the available data on the outcome after control angiography and repeat revascularization in patients with perioperative myocardial ischemia (PMI) after coronary artery bypass grafting (CABG). A literature review was performed through PubMed, Scopus, ScienceDirect and Google Scholar to identify studies published since 1990 evaluating the outcome of PMI after CABG. Nine studies included 1104 patients with PMI after CABG and 1056 of them underwent control angiography early after CABG. Pooled early mortality after reoperation for PMI without control angiography was 43.6% (95%CI 29.7-57.6%) and 79.8% of them (95%CI 64.4-95.2%) had an acute graft failure detected at reoperation. Among patients who underwent control angiography for PMI, 31.7% had a negative finding at angiography (95%CI 25.6-37.8%) and 62.1% had an acute graft failure (95%CI 56.6-67.6%). Repeat revascularization was performed after early control angiography in 46.3% of patients (95%CI 39.9-52.6%; 54.2% underwent repeat surgical revascularization; 45.8% underwent percutaneous coronary intervention). Pooled early mortality after control angiography with or without repeat revascularization was 8.9% (95%CI 6.7-11.1%). Three studies reported on early mortality rates which did not differ between repeat surgical revascularization and PCI (11.7% vs. 9.2%, respectively; risk ratio 1.45, 95%CI 0.67-3.11). In these three series, early mortality after conservative treatment was 5.9% (95%CI 3.6-8.2%). Control angiography seems to be a valid life-saving strategy to guide repeat revascularization in hemodynamically stable patients suffering PMI after CABG.