Histopathological staining remains the fibrosis diagnostic gold standard yet suffers from staining artifacts and variability. Nonlinear optical techniques (e.g., spontaneous fluorescence, Second Harmonic Generation) enhance accuracy but struggle with rapid trace-level detection of fibrosis. To address these limitations, a dual-channel nonlinear optical imaging system with excitation wavelengths at 780 nm and 820 nm was developed, enabling simultaneous spontaneous fluorescence and second-harmonic generation imaging through grid localization. This study applies dual-modality nonlinear imaging to achieve label-free, high-resolution visualization of pulmonary and renal fibrosis at the ECM microstructure scale. Through leveraging this system, it is demonstrated that collagen can be rapidly detected via spontaneous fluorescence at 780 nm, whereas the spatial distribution of collagen fibrils is precisely mapped using Second Harmonic Generation at 820 nm. This approach allows for the rapid and sensitive detection of trace fibrosis in a 5-day unilateral ureteral obstruction mouse model. Additionally, we identify that the elastic fibers, which can also be visualized, provide a foundation for staging diagnosis and delivering accurate and quantitative data for pathological studies and analysis. The research findings underscore the potential of this dual-channel nonlinear optical imaging system as a powerful tool for rapid, precise, and noninvasive fibrosis detection and staging.
Histopathological staining remains the fibrosis diagnostic gold standard yet suffers from staining artifacts and variability. Although nonlinear optical techniques (e.g., spontaneous fluorescence, Second Harmonic Generation) enhance accuracy but struggle with rapid trace-level detection of fibrosis. To address these limitations, a dual-channel nonlinear optical imaging system with excitation wavelengths at 780 nm and 820 nm was developed, enabling simultaneous spontaneous fluorescence and second-harmonic generation imaging through grid localization. This study applies dual-modality nonlinear imaging to achieve label-free, high-resolution visualization of pulmonary and renal fibrosis at the ECM microstructure scale. Through leveraging this system, it is demonstrated that collagen can be rapidly detected via spontaneous fluorescence at 780 nm, whereas the spatial distribution of collagen fibrils is precisely mapped using Second Harmonic Generation at 820 nm. This approach allows for the rapid and sensitive detection of trace fibrosis in a 5-day unilateral ureteral obstruction mouse model. Additionally, we identify that elastic fibers, which can also be visualized, provide a foundation for staging diagnosis and delivering accurate and quantitative data for pathological studies and analysis. The research findings underscore the potential of this dual-channel nonlinear optical imaging system as a powerful tool for rapid, precise, and non-invasive fibrosis detection and staging.
Ultrafast lasers operating at 740 nm and 820 nm have attracted widespread attention as two-photon light sources for the detection of biological metabolism. Here, we report on a solid-like quartz-encapsulated femtosecond laser with a repetition rate of 80 MHz, delivering 740 nm and 820 nm femtosecond laser pulses. This home-built laser system was realized by employing an erbium-doped 1560 nm fiber laser as the fundamental laser source. A quartz-encapsulated nonlinear frequency conversion stage, consisting of a second-harmonic generation (SHG) stage and self-phase modulation (SPM)-based nonlinear spectral broadening stage, was utilized to deliver 30 mW, 53.7 fs, 740 nm laser pulses and the 15 mW, 60.8 fs, 820 nm laser pulses. Further imaging capabilities of both wavelengths were validated using a custom-built inverted two-photon microscope. Clear imaging results were obtained from mouse kidney sections and pollen samples by collecting the corresponding fluorescence signals. The achieved results demonstrate the great potential of this laser source for advanced two-photon microscopy in metabolic detection.