1 December 2014 in Journal of Performance of Constructed Facilities
This article presents the seismic performance of a timber frame with three-dimensional (3D) rigid connections. The connections were made with self-tapping screws and hardwood blocks were used to support the beams. The frame was designed to resist high seismic excitations with the goal of controlling the drift. The moment-rotation characteristics of the connections were measured in the laboratory by applying static cyclic loads. The frame made of laminated wood beams and columns, and cross-laminated lumber deck, was subjected to seismic, white noise, snapback, and sinusoidal sweep excitations. The synthetic seismic excitation was designed to contain a considerable amount of energy close to the frame’s first natural frequency. The structure showed no significant damage up to a peak ground acceleration of 1.25g. Failure of the frame occurred due to shearing of the columns with a peak ground acceleration of 1.5g. The designed structure fulfilled with current serviceability limits up to 0.8g
9 June 2017 in Wood Science and Technology
14 January 2018 in Advances in Structural Engineering
The seismic performance of three-dimensional moment-resisting timber frames with frictional damping devices was investigated experimentally. This article describes a novel three-dimensional beam-to-column connection which was designed to behave rigidly up to moderate seismic intensities and to start the frictional dissipating behavior at higher intensities. The three-dimensional beam-to-column connection component was initially tested under cyclic loading, and then the connection was mounted in a three-level prototype frame and tested on a shake table. From the cyclic loading tests, the energy dissipation of the proposed beam-to-column connection was higher than the equivalent rigid connection. The frame demonstrated self-aligning capabilities without permanent drift at seismic intensities up to 1.4 g and maintained strength up to high seismic intensities of 2 g. Because wood frames allow for large elastic deflections and can exhibit excellent self-aligning capabilities (i.e., connections tolerate large rotations within safe stress levels), the proposed frictional beam-to-column connection is a promising alternative for moment-resisting timber frames that can be used to prevent structural members from reaching critical stresses.
1 December 2013 in Journal of Materials in Civil Engineering
This is an author's peer-reviewed final manuscript, as accepted by the publisher. The published article is copyrighted by the American Society of Civil Engineers and can be found at: http://ascelibrary.org/journal/jmcee7.Remediation methods and strength predictions were evaluated for wood I-joists with single, circular holes in the webs, leaving utilities in place. A full-scale bending test using four equally-spaced point loads was applied to three depths of joists with varying flange widths and span lengths of 4.88 m and 2.44 m. Failure modes for long span joists without holes were in the flanges in tension, compression or lateral buckling; but once a hole was introduced the majority failed in shear. The curved beam approach and manufacturers software were employed to predict strength. Seven remediation techniques were investigated initially, and remediation effectiveness was evaluated based on strength, stiffness, and ease of installation/cost. The oriented strand board (OSB) collar remediation worked very well and returned 8 out of 12 series of joists to a strength statistically equivalent to the “No Hole” condition. The OSB collar was not quite as effective in returning stiffness to the joists, but was easier to install and less expensive than a laminated strand lumber patch
1 August 2016 in Journal of Materials in Civil Engineering
Single-blow impact testing of spruce and pine specimens were done to assess the effects of additional E-glass reinforcing on the tension face of a beam along with a rubber lamina adhered to the impact face. Comparisons between classic three-point static bending and dynamic pendulum tests proved the wood specimens did not absorb more energy in a dynamic loading; conversely, when reinforced with E-glass the spruce specimens absorbed about 2.5 times more energy, and the pine specimens absorbed 1.4 times more energy. The pine specimens treated with rubber and E-glass absorbed only about 1.5 times more energy, indicating a minimal positive effect by adding rubber. The most critical aspect of testing was the strain rate sensitivity of the E-glass.
19 May 2018 in Materials and Structures