Yuki MORISHITA

Dr. Yuki MORISHITA

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YMYuki MORISHITA
Yuki MORISHITA
TTTatsuo Torii
Tatsuo Torii
HUHiroshi Usami
Hiroshi Usami
HKHiroyuki Kikuchi
Hiroyuki Kikuchi
WUWataru Utsugi
Wataru Utsugi
STShiro Takahira
Shiro Takahira
We measured alpha emitters obtained from a reactor building in the Fukushima Daiichi Nuclear Power Plant (FDNPP) by using an alpha particle imaging detector. For developing the detector, we used a very thin (0.05-mm-thick) a cerium-doped Gd3(Ga,Al)5O12 (Ce:GAGG) scintillator and silicon photomultiplier (SiPM) arrays as the photodetector. The floor of the reactor building in FDNPP was wiped off by using smear papers, and the radioactivity of these papers was measured by the alpha particle imaging detector. In addition, we measured a Plutonium (Pu) sample (mainly 5.5 MeV alpha particles from 238Pu) obtained from a nuclear fuel facility by using of the same detector for comparison with the smear papers. The alpha spectrum was in the energy range of 5–6 MeV, which corresponds to the alpha particle energy of 238Pu (5.5 MeV). The correlation coefficient of the alpha spectra of the smear papers and the Pu sample had a strong positive linear relation. Moreover, the peak of 241Am was identified by gamma spectrum measurement. Based on these results, we report actual findings of alpha emitters in the FDNPP reactor buildings originating from nuclear fuels. The surface contamination level of alpha emitters exceeded 4 Bq/cm2.

13 March 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YMYuki MORISHITA
Yuki MORISHITA
KHKatsuya Hoshi
Katsuya Hoshi
TTTatsuo Torii
Tatsuo Torii

27 February 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
SKShohei Kodama
Shohei Kodama
SKShunsuke Kurosawa
Shunsuke Kurosawa
YMYuki MORISHITA
Yuki MORISHITA
HUHiroshi Usami
Hiroshi Usami
TTTatsuo Torii
Tatsuo Torii
AYAkira Yoshikawa
Akira Yoshikawa
!A new red-emitting halide scintillator Rb2HfI6 was developed using the vertical Bridgman furnace and quartz ampoule. Under X-ray irradiation, Rb2HfI6 had a broad emission band around 725 nm. The light output and energy resolution were determined to be ~40,000 photons/MeV and ~7.4% (full width at half maximum at 662 keV), respectively. Since red photons are transmitted with smaller losses than blue or yellow photons inside an optical fiber, long-fiber-reading radiation detection system using the high light-output red scintillator can be established for severe or hazardous environments. We fabricated Rb2HfI6 scintillation crystal and performed the gamma-ray detection test under high dose irradiation condition from a 60Co source with activity of ~100 TBq. The dynamic range of the Rb2HfI6 gamma-ray detection with a 20-m optical fiber was evaluated and compared with the previously-developed Cs2HfI6 crystal and conventional deep-red Cr:α-Al2O3 (ruby) scintillator. The gamma-ray doses from ~0.4 to ~1 kSv/h were successfully measured using Rb2HfI6 through the 20-m fiber.

1 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
YMYuki MORISHITA
Yuki MORISHITA

24 December 2022 in Radiation Measurements
Verified
Journal Article
Open access
YMYuki MORISHITA
Yuki MORISHITA
KTKoji Takasaki
Koji Takasaki
YKYoshiharu Kitayama
Yoshiharu Kitayama
ATAkihiro Tagawa
Akihiro Tagawa
TSTakuya Shibata
Takuya Shibata
MOMasatoshi Oura
Masatoshi Oura

7 August 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
YMYuki MORISHITA
Yuki MORISHITA
KIKenji Izaki
Kenji Izaki
JKJunichi H. Kaneko
Junichi H. Kaneko
SYSeiichi Yamamoto
Seiichi Yamamoto
MHMikio Higuchi
Mikio Higuchi
TTTatsuo Torii
Tatsuo Torii
We developed a Gd2Si2O7 (GPS) scintillator-based alpha imaging detector and demonstrated its effectiveness by evaluating actual Pu particle and 222Rn progeny. The GPS scintillator plate was prepared by a sintering method. The outer dimensions of the GPS scintillator plate were 5 × 5 cm, and the scintillator layer was approximately 50μm. on a 3-mm-thick high-transparency glass. The plate was optically coupled to a position-sensitive photomultiplier tube (Hamamatsu H8500, Hamamatsu, Japan) with silicone grease. The developed imaging detector exhibited good uniformity; Pu particle activities were accurately evaluated at 14 different positions, and the difference in activity was within ± 6%. Radon-222 progeny counts were reduced by 65.3% by applying an energy window. Although the Pu/222Rn progeny activity ratio was 1/51, the Pu particle was successfully identified among 222Rn progeny within the 5 min-measurement time. The imaging detector has an excellent ability for detecting Pu among 222Rn progeny. Thus, this detector is useful for alpha contamination monitoring in high-radon-background environments.