Wei Xu

Dr. Wei Xu

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2021 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
Weimin LyuWeimin Lyu
Weimin Lyu
WXWei Xu
Wei Xu
FYFangang Yang
Fangang Yang
SCShuyang Chen
Shuyang Chen
FTFengze Tan
Fengze Tan
Changyuan YUChangyuan YU
Changyuan YU
Cardiovascular diseases (CVDs) are very common in modern society, such as atherosclerosis, hypertension, etc., which have a great impact on heart function. Therefore, hospitalization monitoring alone is far from enough. Long-term monitoring of the heart is needed in daily life. The technology of non-invasive monitoring of the cardiovascular system can meet the needs of long-term monitoring of the heart condition, helping to promote the improvement of lifestyle and daily care, reducing the overall risk of developing CVDs. The purpose of this study is to investigate the cardiac response after different exercises using a $3\times 3$ demodulation scheme-based ballistocardiography (BCG) monitoring system. A fiber optic sensor (FOS)-based smart cushion is used to replace the traditional inconvenient electrocardiogram (ECG) for heart rate variability (HRV). The correlation between BCG inter-beat interval (IBI) and ECG IBI is 0.9862, and the RMSE is 0.0139. The BCG signal can assess cardiac contractility by analyzing RJ interval with ECG, which is a practical alternative to the pre-ejection period (PEP).

16 November 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WXWei Xu
Wei Xu
Changyuan YUChangyuan YU
Changyuan YU
BDBo Dong
Bo Dong
YWYishan Wang
Yishan Wang
WZWei Zhao
Wei Zhao
A modified solid fiber-optic integrated Mach-Zehnder interferometer (IMZI) assisted with a thin piezoelectric sheet (TPS, ~130 $\mu {\mathrm{ m}}$ thickness) and phase generated carrier (PGC) demodulation is proposed and investigated theoretically and experimentally. The IMZI’s two arms are respectively molded with epoxy resin (EP) and silicone rubber (SI). These two materials are with distinctly different elastic modulus and Poisson ratios, which guarantees the high sensitivity of the IMZI. As for PGC, different modulation frequencies and amplitudes are generated and the corresponding modulation depths are calculated to obtain the optimal modulating parameters. Furthermore, a pair of complementary photodetectors are used to remove unwanted DC component and only the first harmonic is utilized to recover the phase, which can effectively avoid signal fading. In the experiments, where the IMZI is put under the mattress, activity monitoring is addressed and subjects are recruited to investigate the vital signs monitoring performance. The consistency check analysis results show the calculated heart rate variability (HRV) and breath rate variability (BRV) results are highly correlated with reference results, and the Pearson’s r reaches 0.99. Moreover, reliability, post-exercise, and Valsalva Maneuver test are further conducted to verify the repeatability and dynamic monitoring capability. In conclusion, the proposed system is unobtrusive, cost-effective, robust, and convenient, which has great potential in future homecare and hospitalization.

8 March 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FYFangang Yang
Fangang Yang
WXWei Xu
Wei Xu
Weimin LyuWeimin Lyu
Weimin Lyu
FTFengze Tan
Fengze Tan
Changyuan YUChangyuan YU
Changyuan YU
BDBo Dong
Bo Dong
An all-optical active homodyne detection aided fiber-optic Mach-Zehnder interferometer (MZI) vital signs monitoring system is proposed and investigated. The active homodyne detection is mainly realized by employing a wavelength-tunable vertical-cavity surface-emitting laser (VCSEL) and automatic closed-loop control system (CLCS). It can effectively maintain the MZI sensor to operate around the quadrature point and successfully eliminate the fading effect of output signal induced by low frequency drift. Therefore, high fidelity and high stableness of the ballistocardiograph (BCG) signal is guaranteed. The results show that according to the Bland-Altman and the confidence ellipse analysis, the heart rate (HR) monitoring performance reveals high accuracy and good consistence. What’ more, a multiple linear regression-based blood pressure (BP) estimation model is presented, which shows that the BP is highly correlated with I-J-K complex oriented features, including IJ interval, JK interval and JK amplitude. It indeed offers a potential approach to achieve cuff-less BP estimation merely based on the high-fidelity BCG signal. In conclusion, the proposed MZI-BCG monitoring system is simple to use, and it shows great potential in future unobtrusive cardiac monitoring both in home and hospital.

8 February 2022 in Physica Scripta
Verified
Journal Article
Closed access
SLShengxiong Lai
Shengxiong Lai
WXWei Xu
Wei Xu
ZYZhuchuang Yang
Zhuchuang Yang
LLLiming Lu
Liming Lu
KWKun Wang
Kun Wang
Ben-Xin WangBen-Xin Wang
Ben-Xin Wang
Quad-band terahertz metamaterial absorber with near-perfect absorption is given in this paper. It is designed by a patterned Au layer and a continuous Au film separated by an insulating dielectric layer, of which the patterned Au layer is consisted of three parallel Au strips (a longer and two shorter) surrounded by two Au ring arcs of the same size. Four separated terahertz absorption peaks with narrow bandwidths and large absorptance are realized. The first three absorption peaks are due to the fundamental modes of the Au strips and the Au ring arcs, while the fourth absorption peak is ascribed to the excitation of three-order resonance in the Au ring arcs. The field distributions of the four absorption peaks are presented to verify their physical mechanisms. The influence of geometrical dimensions of the proposed configuration on the performance of the quad-band light absorption is discussed. Moreover, considering the potential sensing applications, the sensing performance of the proposed absorption device is also explored. The suggested scheme could provide considerable application prospects in selective thermal radiation, spectral imaging, sensing, detecting, electromagnetic stealth, etc.

4 October 2020
Verified
Conference Paper
Open access
SHShuying Han
Shuying Han
WXWei Xu
Wei Xu
SYShanhong You
Shanhong You
BDBo Dong
Bo Dong
FTFengze Tan
Fengze Tan
YWYishan Wang
Yishan Wang
A smart cushion based on SFS (single-mode-few-mode-single-mode) structure is proposed and experimentally demonstrated, which can be applied in physiological and activity states monitoring simultaneously. The sensing unit embedded in a common cushion is designed as a sandwich structure, consisting of a piece of fiberglass mesh, a SFS structure layer and a polyvinyl chloride (PVC) layer thus the sensitivity can be significantly enhanced. With off-line processing and analyzing of the raw signals collected from the cushion system, the heartbeat rate (HR) and respiratory rate (RR) can be obtained with the maximum error of 1 bpm and the activity states on the cushion can be clearly distinguished within the accuracy of one second. Such a smart cushion has the advantages of low cost, compact structure and high comfort, especially suitable for office workers and the elderly in nursing homes.

29 September 2024 in Optical Fiber Technology
Verified
Journal Article
Closed access
HLHuiyu Li
Huiyu Li
QTQiqi Tu
Qiqi Tu
ZZZhang Zhang
Zhang Zhang
JTJin Tao
Jin Tao
Changyuan YUChangyuan YU
Changyuan YU
WXWei Xu
Wei Xu