13 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TNToshiaki Negishi
Toshiaki Negishi
SAShigeto Abe
Shigeto Abe
Takemi MatsuiTakemi Matsui
Takemi Matsui
HLHe Liu
He Liu
MKMasaki Kurosawa
Masaki Kurosawa
GSGuanghao Sun
Guanghao Sun
Background: In the last two decades, infrared thermography (IRT) has been applied in quarantine stations for the screening of patients with suspected infectious disease. However, the fever-based screening procedure employing IRT suffers from low sensitivity, because monitoring body temperature alone is insufficient for detecting infected patients. To overcome the drawbacks of fever-based screening, this study aims to develop and evaluate a multiple vital sign (i.e., body temperature, heart rate and respiration rate) measurement system using RGB-thermal image sensors. Methods: The RGB camera measures blood volume pulse (BVP) through variations in the light absorption from human facial areas. IRT is used to estimate the respiration rate by measuring the change in temperature near the nostrils or mouth accompanying respiration. To enable a stable and reliable system, the following image and signal processing methods were proposed and implemented: (1) an RGB-thermal image fusion approach to achieve highly reliable facial region-of-interest tracking, (2) a heart rate estimation method including a tapered window for reducing noise caused by the face tracker, reconstruction of a BVP signal with three RGB channels to optimize a linear function, thereby improving the signal-to-noise ratio and multiple signal classification (MUSIC) algorithm for estimating the pseudo-spectrum from limited time-domain BVP signals within 15 s and (3) a respiration rate estimation method implementing nasal or oral breathing signal selection based on signal quality index for stable measurement and MUSIC algorithm for rapid measurement. We tested the system on 22 healthy subjects and 28 patients with seasonal influenza, using the support vector machine (SVM) classification method. Results: The body temperature, heart rate and respiration rate measured in a non-contact manner were highly similarity to those measured via contact-type reference devices (i.e., thermometer, ECG and respiration belt), with Pearson correlation coefficients of 0.71, 0.87 and 0.87, respectively. Moreover, the optimized SVM model with three vital signs yielded sensitivity and specificity values of 85.7% and 90.1%, respectively. Conclusion: For contactless vital sign measurement, the system achieved a performance similar to that of the reference devices. The multiple vital sign-based screening achieved higher sensitivity than fever-based screening. Thus, this system represents a promising alternative for further quarantine procedures to prevent the spread of infectious diseases.

1 February 2017 in International Journal of Infectious Diseases
Verified
Journal Article
Open access
GSGuanghao Sun
Guanghao Sun
YNYosuke Nakayama
Yosuke Nakayama
SDSumiyakhand Dagdanpurev
Sumiyakhand Dagdanpurev
SAShigeto Abe
Shigeto Abe
HNHidekazu Nishimura
Hidekazu Nishimura
TMTakemi Matsui
Takemi Matsui
Infrared thermography (IRT) is used to screen febrile passengers at international airports, but it suffers from low sensitivity. This study explored the application of a combined visible and thermal image processing approach that uses a CMOS camera equipped with IRT to remotely sense multiple vital signs and screen patients with suspected infectious diseases. An IRT system that produced visible and thermal images was used for image acquisition. The subjects' respiration rates were measured by monitoring temperature changes around the nasal areas on thermal images; facial skin temperatures were measured simultaneously. Facial blood circulation causes tiny color changes in visible facial images that enable the determination of the heart rate. A logistic regression discriminant function predicted the likelihood of infection within 10s, based on the measured vital signs. Sixteen patients with an influenza-like illness and 22 control subjects participated in a clinical test at a clinic in Fukushima, Japan. The vital-sign-based IRT screening system had a sensitivity of 87.5% and a negative predictive value of 91.7%; these values are higher than those of conventional fever-based screening approaches. Multiple vital-sign-based screening efficiently detected patients with suspected infectious diseases. It offers a promising alternative to conventional fever-based screening.

1 March 2015 in Journal of Infection
Verified
Journal Article
Closed access
GSGuanghao Sun
Guanghao Sun
Takemi MatsuiTakemi Matsui
Takemi Matsui
YHYukiya Hakozaki
Yukiya Hakozaki
SAShigeto Abe
Shigeto Abe

4 November 2016 in Frontiers in Psychiatry
Verified
Journal Article
Open access
PDF file
GSGuanghao Sun
Guanghao Sun
TSToshikazu Shinba
Toshikazu Shinba
TKTetsuo Kirimoto
Tetsuo Kirimoto
TMTakemi Matsui
Takemi Matsui
Background and Objectives: Heart rate variability (HRV) has been intensively studied as a promising biological marker of major depressive disorder (MDD). Our previous study confirmed that autonomic activity and reactivity in depression revealed by HRV during rest and mental task (MT) conditions can be used as diagnostic measures and in clinical evaluation. In this study, logistic regression analysis (LRA) was utilized for the classification and prediction of MDD based on HRV data obtained in an MT paradigm. Methods: Power spectral analysis of HRV on R-R intervals before, during, and after an MT (random number generation) was performed in 44 drug-naïve patients with MDD and 47 healthy control subjects at Department of Psychiatry in Shizuoka Saiseikai General Hospital. Logit scores of LRA determined by HRV indices and heart rates discriminated patients with MDD from healthy subjects. The high frequency (HF) component of HRV and the ratio of the low frequency (LF) component to the HF component (LF/HF) correspond to parasympathetic and sympathovagal balance, respectively. Results: The LRA achieved a sensitivity and specificity of 80.0% and 79.0%, respectively, at an optimum cutoff logit score (0.28). Misclassifications occurred only when the logit score was close to the cutoff score. Logit scores also correlated significantly with subjective self-rating depression scale scores (p < 0.05). Conclusion: HRV indices recorded during a mental task may be an objective tool for screening patients with MDD in psychiatric practice. The proposed method appears promising for not only objective and rapid MDD screening, but also evaluation of its severity.

20 May 2019 in IEEE Access
Verified
Journal Article
Open access
HLHe Liu
He Liu
DCDeyun Chen
Deyun Chen
GSGuanghao Sun
Guanghao Sun
Fetal electrocardiograph (fECG) R-wave detection from maternal abdominal ECGs (aECGs) is challenging as it is easily distorted and often overwhelmed by a variety of unavoidable interference signals. In this study, we combined RR time-series smoothing with a template-matching (TM) approach to detect fECG R waves from a single-lead aECG. According to the quasi-periodicity of the R wave, we analyzed the cases of misaligned and missed R wave detection in the RR time series and developed an amendment algorithm to distinguish and correct them. The fECG R wave detection consisted of two stages. Firstly, an fECG R wave, which did not overlap with the maternal ECG QRS complex (mQRS), was detected. Subsequently, the amendment algorithm corrected the misaligned and missed R waves and predicted the approximate region of the fECG R wave that overlapped with the mQRS. A TM algorithm was implemented to detect the fECG R wave that overlapped with the mQRS in the approximate region. The fECG QRS complex (fQRS) and mQRS templates were built from the detected fQRS and mQRS that did not overlap with the fQRS, respectively, using singular value decomposition. The TM algorithm then determined the accurate location when the most optimal correlation occurred between the actual mQRS and the superposition of the mQRS and fQRS templates in the approximate region. The performance of the proposed method was assessed using F1 measure and Bland-Altman analysis. High accuracy values were obtained corresponding to 95.

21 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YIYuki Iwata
Yuki Iwata
HTHan Trong Thanh
Han Trong Thanh
GSGuanghao Sun
Guanghao Sun
KIKoichiro Ishibashi
Koichiro Ishibashi
Heart rate measurement using a continuous wave Doppler radar sensor (CW-DRS) has been applied to cases where non-contact detection is required, such as the monitoring of vital signs in home healthcare. However, as a CW-DRS measures the speed of movement of the chest surface, which comprises cardiac and respiratory signals by body motion, extracting cardiac information from the superimposed signal is difficult. Therefore, it is challenging to extract cardiac information from superimposed signals. Herein, we propose a novel method based on a matched filter to solve this problem. The method comprises two processes: adaptive generation of a template via singular value decomposition of a trajectory matrix formed from the measurement signals, and reconstruction by convolution of the generated template and measurement signals. The method is validated using a dataset obtained in two different experiments, i.e., experiments involving supine and seated subject postures. Absolute errors in heart rate and standard deviation of heartbeat interval with references were calculated as 1.93±1.76bpm and 57.0±28.1s for the lying posture, and 9.72±7.86bpm and 81.3±24.3s for the sitting posture.