Performance tests were carried out for a microchannel printed circuit heat exchanger (PCHE), which was fabricated with micro photo-etching and diffusion bonding technologies. The microchannel PCHE was tested for Reynolds numbers in the range of 100‒850 varying the hot-side inlet temperature between 40 °C–50 °C while keeping the cold-side temperature fixed at 20 °C. It was found that the average heat transfer rate and heat transfer performance of the countercurrrent configuration were 6.8% and 10%‒15% higher, respectively, than those of the parallel flow. The average heat transfer rate, heat transfer performance and pressure drop increased with increasing Reynolds number in all experiments. Increasing inlet temperature did not affect the heat transfer performance while it slightly decreased the pressure drop in the experimental range considered. Empirical correlations have been developed for the heat transfer coefficient and pressure drop factor as functions of the Reynolds number.
This paper presents the heat transfer and pressure drop characteristics of a primary surface heat exchanger (PSHE) with corrugated surfaces. The PSHE was experimentally investigated for a Reynolds number range of 156–921 under various flow conditions on the hot and cold sides. The inlet temperature of the hot side was maintained at 40 °C, while that of the cold side was maintained at 20 °C. A counterflow was used as it has a higher temperature proximity in comparison with a parallel flow. The heat transfer rate and pressure drop were measured for various Reynolds numbers on both the hot and cold sides of the PSHE, with the heat transfer coefficients for both sides computed using a modified Wilson plot method. Based on the results of the experiment, both Nusselt number and friction factor correlations were suggested for a PSHE with corrugated surfaces.
This study investigates the effects of stoichiometry, humidity, cell temperature, and pressure on the performance and the flooding of the proton exchange membrane fuel cell. Values of stoichiometry are 1.5, 2.0, and 2.5 at cell temperatures of 50, 55, and 60 °C, respectively. This study shows that the dimensionless flooding value (FV) is a function of the stoichiometry, humidity, temperature, and pressure. The FV is calculated by using the measured values of temperature, humidity, pressure, and flowrate of the cathode. The effect of the dimensionless number on the flooding of the cathode in the proton exchange membrane fuel cell is analysed in this study. The effects of air stoichiometry, cell temperature, and air humidity are also discussed in this article.