Evidence continues to grow supporting the aerosol transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To assess the potential role of heating, ventilation, and air conditioning (HVAC) systems in airborne viral transmission, this study sought to determine the viral presence, if any, on air handling units in a healthcare setting where coronavirus disease 2019 (COVID-19) patients were being treated. The presence of SARS-CoV-2 RNA was detected in approximately 25% of samples taken from ten different locations in multiple air handlers. While samples were not evaluated for viral infectivity, the presence of viral RNA in air handlers raises the possibility that viral particles can enter and travel within the air handling system of a hospital, from room return air through high-efficiency MERV-15 filters and into supply air ducts. Although no known transmission events were determined to be associated with these specimens, the findings suggest the potential for HVAC systems to facilitate transfer of virions to locations remote from areas where infected persons reside. These results are important within and outside of healthcare settings and may present necessary guidance for building operators of facilities that are not equipped with high-efficiency filtration. Furthermore, the identification of SARS-CoV-2 in HVAC components indicates the potential utility as an indoor environmental surveillance location.
Available information on Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) transmission by small particle aerosols continues to evolve rapidly. To assess the potential role of heating, ventilation, and air conditioning (HVAC) systems in airborne viral transmission, this study sought to determine the viral presence, if any, on air handling units in a healthcare setting where Coronavirus Disease 2019 (COVID-19) patients were being treated. The presence of SARS-CoV-2 RNA was detected in approximately 25% of samples taken from nine different locations in multiple air handlers. While samples were not evaluated for viral infectivity, the presence of viral RNA in air handlers raises the possibility that viral particles can enter and travel within the air handling system of a hospital, from room return air through high efficiency MERV-15 filters and into supply air ducts. Although no known transmission events were determined to be associated with these specimens, the findings suggest the potential for HVAC systems to facilitate transmission by environmental contamination via shared air volumes with locations remote from areas where infected persons reside. More work is needed to further evaluate the risk of SARS-CoV-2 transmission via HVAC systems and to verify effectiveness of building operations mitigation strategies for the protection of building occupants. These results are important within and outside of healthcare settings and may present a matter of some urgency for building operators of facilities that are not equipped with high-efficiency filtration.
The outbreak of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has dramatically transformed policies and practices surrounding public health. One such shift is the expanded emphasis on environmental surveillance for pathogens. Environmental surveillance methods have primarily relied upon wastewater and indoor surface testing, and despite substantial evidence that SARS-CoV-2 commonly travels through space in aerosols, there has been limited indoor air surveillance. This study investigated the effectiveness of integrated surveillance including an active air sampler, surface swabs and passive settling plates to detect SARS-CoV-2 in hospital rooms with COVID-19 patients and compared detection efficacy among sampling methods. The AerosolSense active air sampler was found to detect SARS-CoV-2 in 53.8% of all samples collected compared to 12.1% detection by passive air sampling and 14.8% detection by surface swabs. Approximately 69% of sampled rooms (22/32) returned a positive environmental sample of any type. Among positive rooms, ~32% had only active air samples that returned positive, while ~27% and ~9% had only one or more surface swabs or passive settling plates that returned a positive respectively, and ~32% had more than one sample type that returned a positive result. This study demonstrates the potential for the AerosolSense to detect SARS-CoV-2 RNA in real-world healthcare environments and suggests that integrated sampling that includes active air sampling is an important addition to environmental pathogen surveillance in support of public health.
Wood is often used as an interior surface finish in buildings, including exposed cross-laminated timber panels and other structural mass timber members. Building occupants generally have a positive reaction to visible wood elements used in building interiors due to the visual qualities associated with wood being a natural material. This study aims to identify any thermal comfort impacts of wood interior environments using subjective occupant-reported perceived thermal sensation during two experiments conducted in a climate chamber fitted with either white-painted gypsum wallboard or unfinished laminated Douglas Fir wall panels. In the first experiment, the thermal environment was continually varied while the visual stimulus of the wall type remained constant. Irrespective of wood or white wall treatment type, thermal history played a significant role in the perceived thermal comfort of participants under continually modulating temperatures. In the second experiment, a slightly warm steady-state thermal environment was maintained while one of the two wall treatments was revealed from behind a black curtain. While the shift in thermal sensation toward neutral was greater with wood walls than with white walls, the difference was not found to be statistically significant and appears to diminish after 15 min of exposure to the new visual surroundings.
Understanding the role of architectural design in identifying the risk of disease transmission is essential for creating resilience in buildings. Here we used a Grasshopper simulation workflow to execute aerosol disease transmission risk estimation coupled with EnergyPlus simulation inputs to assess the impact of architectural factors on the risk of COVID-19 transmission. We simulated the risk for a simple geometry with different window configurations and geographic locations. We observed that increasing the fractional opening of a single window as well as cross ventilation design can increase the outdoor air exchange, which corresponds to substantially reduced risk of disease transmission. Furthermore, indoor relative humidity in cold climates can be significantly lower in winter due to the impacts of increased mechanical heating which translates to an increased risk of infection. We demonstrate that early architectural design decisions implicate the resultant risk of disease transmission indoors that should be prioritized in the future.
1 March 2024 in The Journal of the Acoustical Society of America
Mass timber construction offers a range of benefits to the design industry, including the potential for sustainability and reduced building embodied carbon, biophilia, speed of assembly, and prefabrication. However, these benefits can create acoustical challenges for sound isolation between spaces. Thus, the University of Oregon’s Institute for Health in the Built Environment, in collaboration with the TallWood Design Institute, has developed a micro acoustic chamber as a conceptual testbed, educational resource, and demonstration tool for design professionals and students, to develop new and innovative mass timber acoustic assemblies, understand acoustic implications of material choices in composite form, and comparatively analyze the performance of acoustic detailing decisions more rapidly at a small scale. The chamber hosts specimens that are 813 mm × 813 mm and up to 300 mm thick, far smaller than a typical laboratory acoustic floor/ceiling assembly test chamber, creating known limitations; however, test samples can be cost and material efficient, allowing relative performance differences between assemblies to be evaluated quickly and easily for initial design feedback. This presentation will share how the use of a micro acoustic chamber has been integrated into design education, student, and industry pilot research to accelerate the development of mass timber acoustic solutions.