sujoy kumar dey

sujoy kumar dey

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2019 in Journal of Polymer Research
Verified
Journal Article
Closed access
PDF file
SDsujoy kumar dey
sujoy kumar dey
SCSomenath Chatterjee
Somenath Chatterjee
FSFlorian Spieckermann
Florian Spieckermann
PGPradipta Ghosh
Pradipta Ghosh
SSSutanu Samanta
Sutanu Samanta

2 September 2021 in Advances in Materials and Processing Technologies
Verified
Journal Article
Closed access
SDsujoy kumar dey
sujoy kumar dey
SSSujith Kumar S
Sujith Kumar S
ISI. Sen
I. Sen
SSS. Samanta
S. Samanta
Nowadays research in the biopolymers is prominent area for research in medical fields. The metallic implants are used in many numbers for the orthopaedic surgeries. But some unavoidable issues are arising after surgeries like stress-shielding, osteogenesis imperfection, etc. To overcome such issues, re-surgery is only one painful option available for the patient. Sometimes, this option is not feasible for the weak and old patients, which results in increased life risk in such situation. Hence, a biopolymer may be the best solutions to eliminate such problems. Polyether ether ketone (PEEK) and hydroxyapatite (HA) are having biocompatible characteristic with different mechanical properties. Hence in this paper, three different compositions of PEEK-HA are considered and the composites were prepared using compression moulding technique. To compare the mechanical properties for different compositions of PEEK-HA, the porosity and tensile strength were calculated. Unlike the other techniques, the fracture toughness was evaluated through J-integral method to ensure the matching of the cracking phenomenon with the human bone. Tribological properties, for example, wear resistance and plasticity index for all compositions of PEEK and HA were executed in both static and dynamic mode. The result reveals that PEEK5HA can be used for the possible bone replacement.

3 July 2024 in Journal of Environmental Nanotechnology
Verified
Journal Article
Open access
ASAnkur Singh
Ankur Singh
SDsujoy kumar dey
sujoy kumar dey
AMAkanksha Mishra
Akanksha Mishra
ASAjay Suri
Ajay Suri
This research explores the capability of pectin as a hydrate inhibitor, along with its potential synergy with monoethylene glycol (MEG). The inhibitory performance was evaluated by measuring the induction time (IT) required for hydrate formation under various concentrations (0.25 wt%, 0.5 wt%, and 1 wt%), employing methane gas at a pressure of 7.6 MPa with hydrate equilibrium temperature at 10.45 ℃. The cooling process was meticulously maintained at a consistent rate of 1℃ per hour below the hydrate equilibrium temperature throughout the experiment. Results revealed that while pectin exhibited slightly lower performance compared to commercial Kinetic Hydrate Inhibitors (KHIs), it demonstrates promising potential as a viable alternative to traditional non-biodegradable and unsustainable KHIs. However, when blended with MEG, its performance increased rapidly. This is particularly significant for the smooth operation of the oil and gas industry offshore, where environmental concerns take precedence. The ability of pectin and MEG combination to effectively inhibit hydrate formation, combined with their biodegradable properties, positions it as an attractive candidate for future research in the field of deep-sea hydrate risk management.

1 June 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
BMBarnak Mukherjee
Barnak Mukherjee
SDsujoy kumar dey
sujoy kumar dey
BPB.B. Pradhan
B.B. Pradhan
The pledge to serve humanity by increasing the quality of human life suffering with paralysed lower half or having paraplegia (i.e. weak lower part of the body) by offering assistance or restoration of the leg mobility along with giving the benefits of well-being throughout numerous physical systems. Schematic study about the exoskeletons, covering the sightings over following topics: (i) Practicality of the powered exoskeletons on the basis of medical safety, (ii) Pros and cons of people using the technology having spinal cord injury (SCI), (iii) Severity of the injuries covered, (iv) The resulting outcomes and, (v) Future aspects about the exoskeleton technology. Researching through the internet and various other sources to understand and identify the medical experimentation and about safety procedures with bottom extremity (lower half of the body), powered exoskeletons for people suffering from SCI. The studies conducted with nine robotic powered exoskeletons, which have been based on specific outline, demographics, tenure of the research, and the initial and final assessment of the exoskeletons. Researches reveal the severity of the injury specifically T10 injuries sums up to a total of 46% of total surveys. A categorical subdivision of the total resulting outcomes shows more than 60% of these measures were related to their style of walking or their type of locomotion, along with their energy consumption (more than 12%), psychic upliftment (13%), and usefulness and ease (less than 10%). Summing up the outcome measures varied through different experiments along with no-one had measures dealing with categorical spreading which made the comparisons little difficult. A brief study reveals that maximum of the recent researches which were made focus on thoracic injuries, also there is a stress on locomotion related preliminary outcome measures. Upcoming studies should stress on the following subjects (i) to develop criteria for skilful knowledge of people to get the utmost benefit from such technology, (ii) design a unique gait detection system which tracks and benefits the user, (iii) adaptation of comprehensive metrics for assessment on the grounds of the safety, profits, and practicality.

18 September 2014 in Journal of The Institution of Engineers (India): Series C
Verified
Journal Article
Closed access
PDF file
SDsujoy kumar dey
sujoy kumar dey
DDD. Datta
D. Datta
SSS. Samanta
S. Samanta

1 January 2023 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
YSYalamanchili Adi Venkata Sandeep
Yalamanchili Adi Venkata Sandeep
SDsujoy kumar dey
sujoy kumar dey
MRManish Kumar Roy
Manish Kumar Roy
RPRuben Phipon
Ruben Phipon
Industrialization and growth in the automobile industry of the world had seen enormous growth in the demand for conventional petroleum products. These conventional petroleum product reserves are high in a few geographical locations of the globe. So, there is a crisis in the availability of petroleum products in the locomotive industry. Due to these reasons, the necessity of alternative fuels is increased. As a result, it is vital to look for alternative fuels made from locally available materials and resources. This paper reviews various alternative fuels like alcohols, biofuels, fuel cells, etc. used in the Indian transport system, government initiatives to change itself into alternative fuels in the coming future.