In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.
Photon-counting detector CT (PCD CT) has increasingly garnered interest in cardiothoracic imaging due to its high spatial resolution and ability to perform spectral imaging. CT plays an important role in the planning and postprocedural assessment of transcatheter aortic valve replacement (TAVR). Limitations of current CT technology resulting in blooming and metal artifacts may be addressed with PCD CT. This case series demonstrates the potential advantages of PCD CT in patients prior to and post-TAVR. In TAVR planning, PCD CT allowed for a detailed depiction of the aortic valve, aortic root, coronary arteries, and potential vascular access routes. The high-spatial-resolution reconstructions enabled assessment of hypoattenuating leaflet thickening and periprosthetic leakage for prosthetic valves. This study shows promising initial results, but further research is needed to determine the clinical impact of PCD CT in patients prior to and post-TAVR.
Prosthesis-patient mismatch after transcatheter aortic valve replacement (TAVR) can be measured echocardiographically (measured prosthesis-patient mismatch [PPMm]) or predicted (predicted prosthesis-patient mismatch [PPMp]) using published effective orifice area (EOA) reference values. However, the clinical implications of PPM post-TAVR remain unclear. This study aimed to elucidate the prevalence of PPMm and PPMp post-TAVR and their impact on mortality in a large international cohort. The IMPPACT TAVR (Impact of Measured or Predicted Prosthesis-pAtient mismatCh after TAVR) registry included 38,808 TAVR patients from 26 international centers. Valve Academic Research Consortium 3 criteria were used to define prosthesis-patient mismatch severity. EOA was determined echocardiographically (PPMm) or predicted (PPMp) based on core lab-derived EOA reference values. The primary endpoint was 2-year all-cause mortality. The prevalence of PPMp (moderate: 6.8%, severe: 0.6%) was significantly lower than that of PPMm (moderate: 20.7%, severe: 4.3%; P < 0.001) with negligible correlation between the 2 methods (Kendall's tau c correlation coefficient: 0.063; P < 0.001). In unadjusted analyses, severe PPMm adversely influenced 2-year survival (HR: 1.22; 95% CI: 1.02-1.45; P = 0.027), whereas severe PPMp was not associated with outcomes (HR: 0.81; 95% CI: 0.55-1.19; P = 0.291). After adjusting for confounders, neither PPMm nor PPMp had a significant effect on 2-year all-cause mortality. PPMm and PPMp were associated with different patient characteristics, with PPMm tending toward worse (especially low flow) and PPMp toward better (especially women) survival. After adjusting for confounders, neither PPMm nor PPMp significantly affected 2-year all-cause mortality. Hence, valve selection should not solely be based on hemodynamics but rather on a holistic approach, including patient and procedural specifics.
To date the value of fasting plasma acylated (AG) and unacylated (UAG) as potential novel biomarkers in patients with neuroendocrine tumors (NETs) is unknown. To 1) compare fasting AG and UAG levels between non-obese, non-diabetic NET patients (N=28) and age- (±3 years) and sex-matched non-obese, non-diabetic controls (N=28), and 2) study the relationship between AG, UAG and AG/UAG ratios and biochemical (chromogranin-A (CgA) and neuron-specific enolase (NSE) levels) and clinical parameters (age at diagnosis, sex, primary tumor location, carcinoid syndrome, ENETS TNM classification, Ki-67 proliferation index, grading, prior incomplete surgery) in NET patients. Fasting venous blood samples (N=56) were collected and directly stabilized with 4-(2-Aminoethyl) benzenesulphonyl fluoride hydrochloride after withdrawal. Plasma AG and UAG levels were determined by ELISA. Expression of ghrelin was examined in tumor tissue by immunohistochemistry. There were no significant differences between NET patients and controls in AG (median: 62.5 pg/ml, IQR: 33.1-112.8 versus median: 57.2 pg/ml, IQR: 26.7-128.3, p=0.66) and UAG in levels (median: 76.6 pg/ml, IQR: 35.23-121.7 versus median: 64.9, IQR: 27.5-93.1, p=0.44). No significant correlations were between AG, UAG and AG/UAG ratios versus biochemical and clinical parameters in NET patients with the exception of age at diagnosis (AG: ρ=-0.47, p=0.012; AG/UAG ratio: ρ=-0.50, p=0.007) and baseline chromogranin-A levels (AG/UAG ratio: ρ=-0.44, p=0.019). In our hands, fasting plasma acylated and unacylated ghrelin appear to have no value as diagnostic biomarkers in the clinical follow-up of patients with NETs.
1 November 2024 in Circulation: Cardiovascular Interventions
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged <75 years receiving TAVR versus surgery. METHODS: The Evolut Low Risk Trial randomized 1414 low-risk patients to treatment with a supra-annular, self-expanding TAVR or surgery. We compared rates of all-cause mortality or disabling stroke, associated clinical outcomes, and bioprosthetic valve performance at 3 years between TAVR and surgery patients aged <75 years. RESULTS: In patients <75 years, 352 were randomized to TAVR and 351 to surgery. Mean age was 69.1±4.0 years (minimum 51 and maximum 74); Society of Thoracic Surgeons Predicted Risk of Mortality was 1.7±0.6%. At 3 years, all-cause mortality or disabling stroke for TAVR was 5.7% and 8.0% for surgery ( P =0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P =0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P <0.001). Valve reintervention rates (TAVR 1.5%, surgery 1.5%, P =0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients ( P <0.001) and lower rates of severe prosthesis-patient mismatch ( P <0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT02701283.