In the present work, an industrial-scale experiment on ventilation air methane (VAM) utilization by a multibed thermal flow-reversal reactor (TFRR) is conducted in China. The influence of the inlet flow rate, feed methane concentration, and cycle time on the temperature distribution of the bed and heat recovery efficiency are investigated. The methane conversion in the studied cases exceeds 97%. The results show that the methane concentration during self-maintained operation of the TFRR without heat recovery should not be less than 0.22 vol % when the inlet flow rate is 103,000 Nm3/h and the cycle time is 300 s. As the inlet flow rate decreases, the lower concentration limit of automatic thermal maintenance increases. The peak temperature of the bed approaches the inlet side as the feed methane concentration increases and the cycle time decreases. The heat recovery efficiency increases linearly with increasing inlet flow rate, rises parabolically with an increasing feed methane concentration, and decreases weakly with increasing cycle time.
25 June 2011 in Microgravity Science and Technology
The paper uses computational fluid dynamics software FLUENT to build a single-channel numerical simulation model of the mine ventilation gas Thermal Flow-Reversal Reactor (TFRR). Combining with the analysis of orthogonal test, the influences that four factors (Initial temperature distribution, Ventilation gas flow velocity, Volume fraction of methane, Exchange period) act on reactor performance is investigated. An optimal operation condition is proposed by the establishment of the priority sequence of these four factors.
In this study, three-dimensional numerical simulations were established for a honeycomb ceramic conduit, and the effects of the inlet methane volume fraction, inlet velocity, and the conduit length on the gas temperature and flow resistance in the conduit were investigated. The simulation results indicate that the mean gas temperature first rises rapidly and then slowly, with an increasing inlet methane volume fraction. The mean gas temperature increases slightly with an increasing inlet velocity, and first increases and then decreases with an increasing conduit length. As the inlet methane volume fraction increases, the conduit pressure loss increases, but the increase rate gradually slows down. The conduit pressure loss increases approximately linearly with an increasing inlet velocity and conduit length. A prediction model for the pressure loss in the conduit was obtained by a theoretical analysis. The theoretical results agree well with the simulation results, and the deviations between the theoretical and simulation results were in the range of 3.7% to 12.3%. When the mean gas temperature in the conduit was less than 1000 K, the deviations were less than 6.5%.