One of the most common challenges in brain MRI scans is to perform different MRI sequences depending on the type and properties of tissues. In this paper, we propose a generative method to translate T2-Weighted (T2W) Magnetic Resonance Imaging (MRI) volume from T2-weight-Fluid-attenuated-Inversion-Recovery (FLAIR) and vice versa using Generative Adversarial Networks (GAN). To evaluate the proposed method, we propose a novel evaluation schema for generative and synthetic approaches based on radiomic features. For the evaluation purpose, we consider 510 pair-slices from 102 patients to train two different GAN-based architectures Cycle GAN and Dual Cycle-Consistent Adversarial network (DC2Anet). The results indicate that generative methods can produce similar results to the original sequence without significant change in the radiometric feature. Therefore, such a method can assist clinics to make decisions based on the generated image when different sequences are not available or there is not enough time to re-perform the MRI scans.
Selective delivery of imaging agents to target cells remains a major challenge for molecular imaging and targeted therapy. Folate-based targeting leverages the differential expression of folate receptors (FRs), which are frequently overexpressed in various malignancies and in activated macrophages compared with most normal tissues, to mediate selective cellular uptake. Folate and folate-conjugates offer several advantages for targeted delivery: 1) restricted normal-tissue distribution of FRs, 2) high affinity binding to FRs, and 3) straightforward conjugation chemistry that enables linkage to both therapeutic and imaging moieties. In this narrative review, we summarize recent advances in FR-targeted imaging across multiple modalities (PET, SPECT, MRI, and optical imaging), discuss strategies for probe design and pharmacokinetic optimization, and highlight translational progress from preclinical studies to early clinical applications. We also review emerging applications of folate-mediated delivery for gene therapy and immune modulation, and we identify remaining challenges including probe specificity, background uptake, and clinical validation and outline directions for future research and clinical translation.
1 January 2023 in Journal of Cancer Research and Therapeutics
Aim: The diagnosis accuracy of computed tomography (CT) systems and the reliability of calculated Hounsfield Units (HUs) are critical in tumor detection and cancer patients’ treatment planning. This study evaluated the effects of scan parameters (Kilovoltage peak or kVp, milli-Ampere-second or mAS reconstruction kernels and algorithms, reconstruction field of view, and slice thickness) on image quality, HUs, and the calculated dose in the treatment planning system (TPS). Materials and Methods: A quality dose verification phantom was scanned several times by a 16-slice Siemens CT scanner. The DOSIsoft ISO gray TPS was applied for dose calculations. The SPSS.24 software was used to analyze the results and the P-value <0.05 was considered significant. Results: Reconstruction kernels and algorithms significantly affected noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The noise increased and CNR decreased by raising the sharpness of reconstruction kernels. SNR and CNR had considerable increments at iterative reconstruction compared with the filtered back-projection algorithm. The noise decreased by raising mAS in soft tissues. Also, KVp had a significant effect on HUs. TPS--calculated dose variations were less than 2% for mediastinum and backbone and less than 8% for rib. Conclusions: Although HU variation depends on image acquisition parameters across a clinically feasible range, its dosimetric impact on the calculated dose in TPS can be neglected. Hence, it can be concluded that the optimized values of scan parameters can be applied to obtain the maximum diagnostic accuracy and calculate HUs more precisely without affecting the calculated dose in the treatment planning of cancer patients.
1 April 2022 in Journal of Medical Signals & Sensors
Background: The objective of this study was to design and construct a CO2 incubator with nonmetallic walls and to investigate the viability of the cells and microwave irradiance inside this incubator. Methods: Because the walls of conventional incubators are made of metal, this causes scattering, reflection, and absorption of electromagnetic waves. We decided to build a nonmetallic wall incubator to examine cells under microwave radiation. Incubator walls were made using polyvinyl chloride and Plexiglas and then temperature, CO2 pressure, and humidity sensors were placed in it. Atmel® ATmega1284, a low-power CMOS 8-bit microcontroller, collects and analyzes the sensor information, and if the values are less or more than the specified limits, the command to cut off or connect the electric current to the heater or CO2 solenoid valve is sent. Using a fan inside the incubator chamber, temperature and CO2 are uniforms. The temperature of the points where the cell culture plates are placed was measured, and the temperature difference was compared. Ovarian cancer cells (A2780) were cultured in the hand-made and commercial incubators at different times, and cell viability was compared by the MTT method. Microwave radiation in the incubator was also investigated using a spectrum analyzer. The survival of cells after microwave irradiation in the incubator was measured and compared with control cells. Results: The data showed that there was no significant difference in temperature of different points in hand-made incubator and also there was no significant difference between the viability of cells cultured in the hand-made and commercial incubators. The survival of irradiated cells in the incubator was reduced compared to control cells, but this reduction was not significant. Conclusion: This incubator has the ability to maintain cells and study the effects of electromagnetic radiations on the desired cells, which becomes possible by using this device.
1 January 2018 in Journal of Medical Signals & Sensors
Background: In the past, GRID therapy was used as a treatment modality for the treatment of bulky and deeply seated tumors with orthovoltage beams. Now and with the introduction of megavoltage beams to radiotherapy, some of the radiotherapy institutes use GRID therapy with megavoltage photons for the palliative treatment of bulky tumors. Since GRID can be a barrier for weakening the photoneutrons produced in the head of medical linear accelerators (LINAC), as well as a secondary source for producing photoneutrons, therefore, in terms of radiation protection, it is important to evaluate the GRID effect on photoneutron dose to the patients. Methods: In this study, using the Monte Carlo code MCNPX, a full model of a LINAC was simulated and verifed. The neutron source strength of the LINAC (Q), the distributions of flux ( φ ), and ambient dose equivalent (H*[10]) of neutrons were calculated on the treatment table in both cases of with/without the GRID. Finally, absorbed dose and dose equivalent of neutrons in some of the tissues/organs of MIRD phantom were computed with/without the GRID. Results: Our results indicate that the GRID increases the production of the photoneutrons in the LINAC head only by 0.3%. The calculations in the MIRD phantom show that neutron dose in the organs/tissues covered by the GRID is on average by 48% lower than in conventional radiotherapy. In addition, in the uncovered organs by the grid, this amount is reduced to 25%. Conclusion: Based on the fndings of this study, in GRID therapy technique compared to conventional radiotherapy, the neutron dose in the tissues/organs of the body is dramatically reduced. Therefore, there will be no concern about the GRID effect on the increase of unwanted neutron dose, and consequently the risk of secondary cancer.
21 February 2012 in Journal of Radioanalytical and Nuclear Chemistry