Alan Holloway

Dr. Alan Holloway


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2003 in Sensors
Verified
Journal Article
Open access
PDF file
AHAlan Holloway
Alan Holloway
ANA. Nabok
A. Nabok
MTM. Thompson
M. Thompson
ARA. K. Ray
A. K. Ray
DCD. Crowther
D. Crowther
JSJ. Siddiqi
J. Siddiqi
The Impedance analysis technique complimented with curve fitting software was used to monitor changes in film properties of Thickness Shear Mode (TSM) resonator on vapour exposure. The approach demonstrates how sensor selectivity can be achieved through unique changes in film viscosity caused by organic vapour adsorption.

14 May 2020 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
WDWill Daw
Will Daw
RKRuth Nicola Kingshott
Ruth Nicola Kingshott
RSReza Saatchi
Reza Saatchi
DBDerek Burke
Derek Burke
RERobert Evans
Robert Evans
HEHeather Elphick
Heather Elphick
Respiratory rate (RR) is an important vital sign used in the initial and ongoing assessment of acutely ill patients. It is also used as a predictor of serious deterioration in a patient's clinical condition. Convenient electronic devices exist for measurement of pulse, blood pressure, oxygen saturation, and temperature. Although devices which measure RR exist, none has entered everyday clinical practice. We have developed a contactless portable respiratory rate monitor (CPRM) and evaluated the agreement in respiratory rate measurements between existing methods and our new device. The CPRM uses thermal anemometry to measure breath signals during inspiration and expiration. RR data were collected from 52 healthy adult volunteers using respiratory inductance plethysmography (RIP) bands (established contact method), visual counting of chest movements (established noncontact method), and the CPRM (new method), simultaneously. Two differently shaped funnel attachments to the CPRM were evaluated for each volunteer. Data showed a good agreement between measurements from the CPRM and the gold standard RIP, with intraclass correlation coefficient (ICC): 0.836, mean difference 0.46 and 95% limits of agreement of −5.90 to 6.83. When separate air inlet funnels of the CPRM were analyzed, stronger agreement was seen with an elliptical air inlet; ICC 0.908, mean difference 0.37 with 95% limits of agreement −4.35 to 5.08. A contactless device for accurately and quickly measuring respiratory rate will be an important triage tool in the clinical assessment of patients. More testing is needed to explore the reasons for outlying measurements and to evaluate in the clinical setting.

14 April 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
RSReza Saatchi
Reza Saatchi
AHAlan Holloway
Alan Holloway
JTJonathan Travis
Jonathan Travis
HEHeather Elphick
Heather Elphick
WDWill Daw
Will Daw
RERobert L. Evans
Robert L. Evans
Respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its measurement is currently subjective, relying on visual counting of chest movements. The design of a new RR measurement device utilising a self-heating thermistor as its sensing element is described. The thermistor is situated in a hand-held air chamber with a funnel attachment that detects respiratory airflow up to 30 cm from the face. The exhaled respiratory airflow reduces the temperature of the thermistor, and its temperature recovers during inhalation. A microcontroller provides signal processing while its display screen shows the respiratory signal and RR. The device has been evaluated on 27 healthy adult volunteers, mean age 32.8 years (standard deviation 8.6 years). The RR readings from the device were compared with the visual counting of chest movements and the contact method of inductance plethysmography implemented using a commercial device (SOMNOtouch™ RESP). The RR readings from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm respectively. The device has a robust operation, is easy to use and gives an objective measure of RR in a non-contact manner.

9 June 2025 in Technologies
Verified
Journal Article
Open access
PDF file
RSReza Saatchi
Reza Saatchi
AHAlan Holloway
Alan Holloway
JTJohnathan Travis
Johnathan Travis
HEHeather Elphick
Heather Elphick
WDWill Daw
Will Daw
RERobert L. Evans
Robert L. Evans
The respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its current measurement has limitations, relying on visual counting of chest movements. The design of a new RR measurement device utilizing a self-heating thermistor is described. The thermistor is integrated into a hand-held air chamber with a funnel attachment to sensitively detect respiratory airflow. The exhaled respiratory airflow reduces the temperature of the thermistor that is kept at a preset temperature, and its temperature recovers during inhalation. A microcontroller provides signal processing, while its display screen shows the respiratory signal and RR. The device was evaluated on 27 healthy adult volunteers, with a mean age of 32.8 years (standard deviation of 8.6 years). The RR measurements from the device were compared with the visual counting of chest movements, and the contact method of inductance plethysmography that was implemented using a commercial device (SOMNOtouch™ RESP). Statistical analysis, e.g., correlations were performed. The RR measurements from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm, respectively. The device has a robust operation, is easy to use, and provides an objective measure of the RR in a noncontact manner.