Organic soil pollution poses a persistent threat to environmental sustainability by disrupting nutrient cycling and ecosystem functioning. The biochar-activated persulfate (PS)-based advanced oxidation process (AOP) has emerged as a promising strategy for the sustainable remediation of organic-contaminated soils. This review provides a comprehensive overview of the recent progress in the PS-based degradation of organic pollutants, with a particular focus on the role of biochar as an efficient and environmental activator. This review further summarizes advancements in the design of modified biochars, including metal (Fe, Cu, Co, Mn, Zn, and La), non-metal (N, S, B, P), and functional group modifications, aimed at enhancing the PS activation efficiency while minimizing secondary environmental risks. Importantly, the overlooked contributions of soil microorganisms in PS/biochar systems are discussed, highlighting their potential to complement chemical oxidation and contribute to eco-compatible remediation pathways. This review emphasizes the sustainability-oriented evolution of PS/biochar technology, highlighting the importance of a cost-efficient implementation, ecological compatibility, and the rational engineering of smart, regenerable catalysts. These insights support the advancement of PS/biochar-based AOPs toward scalable, intelligent, and environmentally sustainable soil remediation.
A specialized system for accurate self-tapping medical bone screw testing is developed, fully meeting the requirements of ASTM F543-A4 (YY/T 1505-2016). The onset of self-tap is identified automatically according to a change in the slope of the torque curve. Precise load control is applied to determine the self-tapping force accurately. A simple mechanical platform is embedded to ensure the automatic axial alignment of a tested screw with the pilot hole in a test block. In addition, comparative experiments are conducted on different self-tapping screws to verify the system's effectiveness. By the automatic identification and alignment method, both torque curves and axial force curves for each screw exhibit significant consistency. The self-tapping time point derived from the torque curve agrees well with the turning point of the axial displacement curve. The determined self-tapping forces' mean values and standard deviations are both small, which are proved to be effective and accurate in the insertion tests. This work contributes to improving the standard test method for accurate determination of the self-tapping performance of medical bone screws.
6 November 2024 in Journal of Mechanics in Medicine and Biology