Charles A. Goldfarb

Dr. Charles A. Goldfarb


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2001 in Radiology
Verified
Journal Article
Closed access
CGCharles A. Goldfarb
Charles A. Goldfarb
YYYuming Yin
Yuming Yin
LGLouis A. Gilula
Louis A. Gilula
AFAndrew J. Fisher
Andrew J. Fisher
MBMartin I. Boyer
Martin I. Boyer
With the recent improvements in diagnosis and treatment of distal radius and carpal injuries, the hand surgeons’ expectations of relevant radiologic interpretation of imaging studies are heightened. Conventional radiographic examinations, as well as more sophisticated and invasive studies, have important roles in the evaluation of wrist fractures and dislocations. On the basis of physical examination results and the mechanism of injury, the onus is on the examining surgeon to pinpoint potential sites of bone or ligament disruption. After this evaluation, appropriate imaging studies appropriately performed and interpreted will help direct treatment and improve outcome with greater clarity and certainty.

1 October 2003 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
CGCharles A. Goldfarb
Charles A. Goldfarb
PSPeter J. Stern
Peter J. Stern
The long-term results of silicone metacarpophalangeal arthroplasty in patients with rheumatoid arthritis are uncertain. The purpose of this investigation was to evaluate the subjective, objective, and radiographic outcomes at the time of long-term follow-up. Patients with rheumatoid arthritis who underwent simultaneous silicone metacarpophalangeal joint arthroplasties of all four fingers by one surgeon were eligible for inclusion in the study. The results of a total of 208 arthroplasties in fifty-two hands of thirty-six patients were evaluated at an average of fourteen years postoperatively. Active metacarpophalangeal joint motion, ulnar drift, and radiographs were assessed. The radiographs were reviewed for changes in bone length, erosions, and implant fractures. The Michigan Hand Outcomes Questionnaire (MHQ) was administered to the patients. The mean arc of motion of the metacarpophalangeal joints improved from 30 degrees preoperatively to 46 degrees immediately after the surgery but decreased to 36 degrees at the time of final follow-up. The mean extension deficit of the metacarpophalangeal joints improved from 57 degrees preoperatively to 11 degrees immediately after the surgery but worsened to 23 degrees at the time of final follow-up. The mean ulnar drift improved from 26 degrees preoperatively to <5 degrees in the immediate postoperative period and then recurred to an average of 16 degrees at the time of final follow-up. Implant fractures were associated with increased ulnar drift (p < 0.001). Bone reaction adjacent to the implant was demonstrated by bone-shortening in most patients and by erosions in 29% of the patients. One hundred and thirty implants (63%) were broken and forty-five (22%) more were deformed at the time of final follow-up. The MHQ score averaged 48 of 100 points. The patients expressed satisfaction with the function of only 38% of the hands, and only 27% of the hands were pain-free at the time of final follow-up. A greater degree of ulnar drift was associated with decreased patient satisfaction and a decreased score for the cosmetic appearance (p

1 April 2006 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
CGCharles A. Goldfarb
Charles A. Goldfarb
JRJonas R. Rudzki
Jonas R. Rudzki
LCLouis W. Catalano
Louis W. Catalano
MHMichael Hughes
Michael Hughes
JBJoseph Borrelli
Joseph Borrelli

5 December 2012 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
RCRyan P. Calfee
Ryan P. Calfee
CSChirag M. Shah
Chirag M. Shah
CCColin D. Canham
Colin D. Canham
AWAmbrose H.W. Wong
Ambrose H.W. Wong
RGRichard H. Gelberman
Richard H. Gelberman
CGCharles A. Goldfarb
Charles A. Goldfarb
Y with use of the Constant score and on radiographs in two projections, with special regard to glenoid component loosening, at a mean of eleven years (range, ten to fifteen years) postoperatively. Results: The mean Constant score was 27 points (range, 11 to 54 points) preoperatively and 61 points (range, 21 to 86 points) postoperatively (p < 0.0001). Mean shoulder flexion increased from 84° (range, 40° to 150°) preoperatively to 133° (range, 40° to 180°) postoperatively; mean abduction, from 77° (range, 40° to 110°) to 123° (range, 40° to 180°); and mean external rotation, from 11° (range, −20° to 40°) to 35° (range, 0° to 60°). No humeral components but 36% of the glenoid components were radiographically loose at the time of follow-up. Kaplan-Meier survivorship of the glenoid component was 100% after thirteen years with revision as the end point, whereas survivorship with radiographic loosening as the end point was only 48% after thirteen years. We found no correlation between glenoid loosening on radiographs and clinical findings such as the Constant score. Cranial migration of the humerus was seen in 69% of the cases. Conclusions: With the implants, cementation, and surgical technique utilized in this group of patients with primary glenohumeral osteoarthritis, radiographic loosening of the glenoid component and rotator cuff deficiency were very common at the ten to fifteen-year review. The follow-up was not long enough to fully identify the clinical sequelae of these findings. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence....

1 June 2016 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
KGKendall F Gretsch
Kendall F Gretsch
HLHenry D Lather
Henry D Lather
KPKranti V Peddada
Kranti V Peddada
CDCorey R Deeken
Corey R Deeken
LWLindley B Wall
Lindley B Wall
CGCharles A. Goldfarb
Charles A. Goldfarb
Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable.

1 August 2002 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
JBJoseph Borrelli
Joseph Borrelli
CGCharles A. Goldfarb
Charles A. Goldfarb
LCLouis Catalano
Louis Catalano
BEBradley A. Evanoff
Bradley A. Evanoff
Quantitatively evaluate plain radiographs, relative to computed tomography (CT) scans, for assessment of articular fragment displacement (step and gap) in displaced acetabular fractures and in canine osteotomized acetabular specimens. Retrospective evaluation of a consecutive series of CT scans and plain radiographs of patients with displaced acetabular fractures and canine acetabulae osteotomized to represent acetabular fractures with displacement. Level I trauma center. Computed tomography scans and plain radiographic images of 62 consecutive patients with displaced acetabular fractures were reviewed; 20 patients met the inclusion criteria regarding location, fracture pattern, availability of plain radiographs and CT scans, and the position of the femoral head at the time of radiographic assessment. The hemipelvi of five adult mongrels underwent osteotomy of the acetabulum and similar radiographic evaluation. Three independent reviewers measured step and gap deformity on plain radiographs and CT scans utilizing a standardized measurement technique. Sensitivity and specificity of plain radiographs for detecting step and gap displacement (2 mm and 4 mm) relative to CT scans were determined. Intraclass correlation coefficient and intraobserver reliability was also calculated. For the canine specimens, sensitivities of each imaging method were determined relative to actual fragment displacement measurements. In the clinical images, when compared to CT, plain radiographs showed poor sensitivity at detecting step deformity (sensitivity = 25%). When analyzed by fracture type, plain radiographs were particularly poor at detecting step deformities in fractures involving a single column of the acetabulum (sensitivity = 0%). Excellent intraobserver and intraclass reliability existed among the three reviewers. Computed tomography scans were considerably more accurate in measuring step and gap displacement relative to actual measurements than plain radiographs in the canine specimens. 1) Plain radiographs showed poor sensitivity for the detection of step and gap deformities in patients with acetabular fractures and in osteotomized canine specimens, relative to CT scans; 2) differences between CT and plain radiographs in both specimen types were greatest with the most clinically relevant deformity—i.e., step; and 3) CT scans are essential and should continue to be used in conjunction with plain radiographs in the preoperative evaluation of displaced acetabular fractures and perhaps should be considered in the postoperative assessment of fracture reduction.