Da Xu

Dr. Da Xu

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Chinese Optics
Verified
Journal Article
Closed access
PDF file
DXDa Xu
Da Xu
YSYue Shi-Xin
Yue Shi-Xin
GZGuoyu Zhang
Guoyu Zhang
SGSun Gao-Fei
Sun Gao-Fei
JZJian Zhang
Jian Zhang
In order to satisfy the spectral radiance calibration of remote sensing instruments in different spectral distribution, reduce the influence of spectral radiance calibration light sources on the calibration coefficients of space optical remote sensing instruments, and solve technical problems of low spectral simulation accuracy and small spectral dynamic adjustment range, a design method for Offner type convex grating radiation calibration systems with a wide dynamic range based on spectral superposition and the principles of multi-spectral synthesis was presented, and its anastigmatic conditions were derived. The Offner spectral imaging optical system was designed with a cylindrical mirror with an accurate subdivision of broad spectral beams. Then, the mapping relationship between the array surface of the Digital Micro-mirror Device (DMD) and its spatial spectral radiation distribution was designed. The large dynamic range simulation of spectral distribution with the spatial light modulation characteristics of the DMD was achieved. Experiment results show that the interval of the spectral peak has an output by the adjacent unit array micro-mirror is greater than 0.5 nm, the spectral simulation accuracy of three typical color temperatures is 5.2% at T=3 000 K, 4.1% at T=5 000 K, and 3.2% at T=7 000 K. The spectral simulation accuracy of the radiation calibration source was significantly improved, and the influence of spectral mismatch on the calibration coefficients of space optical remote sensing instruments was effectively diminished.

1 January 2018 in Chinese Journal of Space Science
Verified
Journal Article
Closed access
PDF file
DXDa Xu
Da Xu
GZGuoyu Zhang
Guoyu Zhang
GSGaofei Sun
Gaofei Sun
为实现星敏感器光信号的高精度标定需求,提出了一种具有空间背景光的星敏感器地面标定系统,解决了空间背景光对星敏感器光信号定标精度的影响,提高了星敏感器的标定精度.对空间背景光对星敏感器标定精度的影响进行分析,给出了具有空间背景光的星模拟器实现方案,设计了能同时模拟空间背景光和星点位置信息的星模拟器光学系统.结果表明,该系统全视场相对畸变小于0.01%,MTF在80lp·mm-1处大于0.5,达到了高精度指标要求.设计了一套空间背景光系统,通过对电流和可变光阑的控制,实现了亮度26倍变化.提出了一种基于像差补偿的星点位置修正方法,并给出了修正模型.利用徕卡T6100经纬仪和照度计,分别对星模拟器所在的星点位置误差和空间背景光亮度进行测试.结果表明,空间背景光亮度可实现26倍调整,在最高能量和最低能量下星模拟器星点位置误差精度<10",满足星敏感器地面标定要求.