Phil Ramis

Mr. Phil Ramis

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2024 in Cancer Epidemiology
Verified
Journal Article
Open access
SRSameer Rehman
Sameer Rehman
MLMike Lim
Mike Lim
RSRanjit Sidhu
Ranjit Sidhu
PRPhil Ramis
Phil Ramis
EREric Rohren
Eric Rohren
Despite efforts to improve national lung cancer screening rates, only 4 % of eligible high-risk patients pursue this opportunity annually. The goal of this study was to better understand the system, provider, and patient-level barriers to lung cancer screening METHODS: 300 high-risk patients in the southern Nevada region who met the criteria for lung cancer screening were given a questionnaire during their outpatient visit for low dose chest CT from August 2023 through February 2024. The most common reported barriers were absence of symptoms (38 %), not wishing to know that they had cancer (30 %), and not having awareness of the eligibility for CT screening (24 %). A multifactorial approach is indicated to provide education for high-risk patients to clarify the importance of early diagnosis, demonstrate accessibility and low cost for lung cancer screening, and absolve any misconceptions about lung cancer screening.

Verified
Journal Article
Open access
PDF file
ZNZachary Nuffer
Zachary Nuffer
PRPhil Ramis
Phil Ramis
EREric Rohren
Eric Rohren
GHGary Horn
Gary Horn
Background/Objectives: Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE) in patients with contraindications to anticoagulation, among other indications. Despite clinical guidelines recommending timely retrieval, rates remain suboptimal, raising concerns about long-term complications. This study examines national hospital-level variation in IVC filter retrieval rates and adherence to timing recommendations. Methods: A retrospective analysis was conducted using data from 12,197 patients across 158 U.S. facilities between 1 January 2020, and 29 August 2024. Retrieval rates, time to retrieval, and associations with facility-specific factors such as procedural volume and academic affiliation were evaluated using descriptive statistics and correlation analyses. Results: Facility retrieval rates varied widely, ranging from 0.36% to 100%, with a mean of 23% (SD 24%). Only 43% (SD 12%) of filters were retrieved within 90 days, as recommended. A weak negative correlation was observed between retrieval rate and procedure volume (r = −0.24), as well as patient age (r = −0.17). Several high-volume facilities showed potential guideline non-adherence, placing many filters but retrieving few. No significant differences were found between academic and non-academic institutions in retrieval rate or timing. Conclusions: Substantial variability exists in IVC filter retrieval practices, and many facilities fall short of timely removal benchmarks. These findings highlight the need for targeted quality improvement initiatives to increase retrieval adherence, reduce filter-related complications, and improve patient outcomes.

9 February 2024 in Radiology Research and Practice
Verified
Journal Article
Open access
PDF file
AHAndrew K. Hillman
Andrew K. Hillman
PRPhil Ramis
Phil Ramis
PNPatrick Nielsen
Patrick Nielsen
EREric Rohren
Eric Rohren
Purpose of Study. Our study evaluated the impact of COVID-19 on breast imaging volumes and the recovery of these volumes following availability of COVID-19 vaccination. Method. Data were obtained from medical health records across 77 Radiology Partners practices in the US. The data provided us with the total monthly mammography, breast ultrasound, and breast MRI procedures from January 2019 to September 2022. An interrupted time-series (ITS) analysis was conducted to evaluate the effect of the COVID-19 pandemic and the COVID-19 vaccination. We chose March 2020 and December 2020 as critical time points in the pandemic and analyzed trends before and after these dates. Results. The starting level (at baseline in January 2019) of the total breast imaging procedure volume was estimated at 114,901.5, and this volume appeared to significantly increase every month prior to March 2020 by 4,864.0 ( , CI = [3,077.1, 6,650.9]). In March 2020, there appeared to be a significant decrease in volume by 104,446.3 ( , CI = [−172,063.1, −36,829.5]), followed by a significant increase in the monthly trend of service volume (relative to the pre-COVID trend) of 20,660.7 per month ( , CI = [8,828.5, 32,493.0]). In December 2020, there appeared to be a significant decrease in service volume by 69,791.2 ( , CI = [−123,602.6, −15,979.7]). Compared to the period from March to November 2020, there was a decrease in the monthly trend of service volumes per month by 24,213.9 ( , CI = [−36,027.6, −12,400.2]). After March 2020, the total service volume increased at the rate of 25,524.7 per month ( , CI = [13,828.2, 37,221.2]). In contrast, the service volumes after December 2020 appeared to grow steadily and slowly at a rate of 1,310.8 per month ( , CI = [−348.8, 2970.3]). Conclusion. Our study revealed that there has been a recovery and a further increase in breast imaging service volumes compared to prepandemic levels. The increase can be best explained by vaccination rollout, reopening of elective/nonemergency healthcare services, insurance coverage expansion, the decline in the US uninsured rate due to government interventions and policies, and the recovery of jobs with employer-provided medical insurance post-pandemic.

13 December 2024 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
MWMadison K. Md Wulfeck
Madison K. Md Wulfeck
PRPhil Ramis
Phil Ramis
AHAndrew Hillman
Andrew Hillman
PNPatrick Nielsen
Patrick Nielsen
EREric M. MD Rohren
Eric M. MD Rohren
Rationale: Standardized guidelines for meals used in adult gastric emptying studies (GES) have been available since 2009; however, there is still great variability in the diets that are clinically used in these studies. The purpose of this retrospective study is to perform an observational analysis of GES meals that are used within a national radiology practice to assess for compliance. It is hypothesized that despite having well-validated standardized meal protocols, there remains great variability in its use and interpretation. Methods: This retrospective observational analysis included 11,458 GESs and their associated reports. GES meals were divided into 5 categories including solid, liquid, dual liquid and solid, alternative meals, and other. Further analysis was performed on the solid and liquid meal GESs. The total amount of studies performed with each meal was collected as well as the percentages of the results of each study categorized as normal, delayed, rapid, and limited. Results: A total of 10,602 studies were included in the analysis, which included 9974 solid meals and 628 liquid meals. Of the solid meal type, the standard recommended meal was used most often followed by the protein variant meal. The oatmeal protocol had the least number of delayed results; however, there was otherwise a similar distribution of results for the remaining solid meal variants. The most common liquid meal utilized the nutritional drink or protein shake, and compared with the solid meal types, there were less rapid or limited results. Conclusions: Variability remains in clinical practice regarding the type of meal that is used in GESs as well as in the interpretation of the study. Continued reinforcement of the standardized solid meal diet and validated cutoff values for interpretation remains crucial until there is increased validation and standardization of other diets.

2 July 2025 in International Journal of Radiology Case Reports
Verified
Journal Article
Open access
PDF file
EDEthan D’sIlva
Ethan D’sIlva
AHAndrew K Hillman
Andrew K Hillman
PRPhil Ramis
Phil Ramis
HHHarrison Hardin
Harrison Hardin
SZSyed Zaidi
Syed Zaidi
EREric M Rohren
Eric M Rohren
Objective: Despite the publication of multiple widely accepted guidelines, Computed Tomography Pulmonary Angiography (CTPA) remains overutilized in the emergency (ED) setting for evaluating suspected Pulmonary Embolism (PE). We developed and evaluated a multimodal program that aimed to improve ordering provider adherence to CTPA use guidelines, and consequently positivity rate. Methods: We retrospectively identified all CTPA studies ordered for suspected PE over three years for each provider at a single centre ED, and reviewed radiology reports to determine PE positivity. We then implemented a program that included an education session, individualized performance feedback, and discussion of possible incentives to improve guideline adherence. We prospectively collected CTPA results for the following year. Our primary outcome was the difference in positivity rate between the final pre-intervention year and the post- intervention year. Our secondary outcome was individual provider positivity rate between the pre-intervention and post-intervention period. We compared the primary outcome using chi-squared testing, defining statistical significance as P<0.05. Results: We identified 4265 CTPA studies performed during the pre-intervention period, ordered by 25 providers. 1582 studies were ordered during the final year, with an 11.00% positivity rate (174/1582). In the post intervention year, 1339 studies were ordered, with a significantly greater positivity rate of 13.67% (183/1339, P=0.028). For our secondary outcome, mean provider positivity rate was 11.49% during the pre-intervention period, and increased to 14.24% in the post intervention period. Discussion: We successfully implemented a multimodal program for ED providers that significantly increased the positivity rate of CTPAs ordered for suspected PE evaluation.

22 October 2026 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Open access
SRSameer Rehman
Sameer Rehman
SNShreyas Uttam Naidu
Shreyas Uttam Naidu
SASyed Akbarullah
Syed Akbarullah
JSJoel Schein
Joel Schein
PRPhil Ramis
Phil Ramis
RSRobert Suh
Robert Suh
To evaluate the feasibility, diagnostic yield, and safety of synchronous CT-guided core needle biopsy and cryoablation for highly suspicious 1-2 cm pulmonary nodules MATERIALS AND METHODS: This retrospective single-center study included 102 consecutive patients undergoing synchronous CT-guided core needle biopsy and cryoablation between August 2020 and October 2025. Treatment was undertaken on the basis of clinical and imaging suspicion before final histopathologic diagnosis. A cryoprobe was placed before biopsy to provide an intraprocedural landmark. Technical success, diagnostic yield, and adverse events were evaluated in all 102 patients; local tumor progression and overall survival were evaluated separately in 81 patients with pathology-confirmed NSCLC. Cryoablation technical success was 100% (102/102), and concurrent biopsy diagnostic yield was 87.3% (89/102). Biopsy identified 86 malignant diagnoses, including 81 NSCLCs. Mean nodule diameter was 1.52 ± 0.30 cm. Median follow-up in the NSCLC cohort was 34.5 months (IQR, 18.4-49.4 months). The cumulative incidence of recorded local tumor progression was 8.8% at both 1 and 3 years, and overall survival was 100% and 90.8%, respectively. Pneumothorax requiring chest tube drainage occurred in 20.6% (21/102), and no procedure-related deaths were reported. The synchronous biopsy and cryoablation approach was technically feasible and provided a specific histopathologic diagnosis in 87.3% of selected patients with highly suspicious 1.0-2.0-cm pulmonary nodules. Among patients with pathology-confirmed NSCLC, local-control outcomes were within the range reported in similar cryoablation-only series.