Zeti Adura Che Ab Aziz

Prof. Zeti Adura Che Ab Aziz


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in International Journal of Biomaterials
Verified
Journal Article
Open access
PDF file
AAAfaf Yahya Al-Haddad
Afaf Yahya Al-Haddad
MKMuralithran Govindan Kutty
Muralithran Govindan Kutty
ZAZeti Adura Che Ab Aziz
Zeti Adura Che Ab Aziz
Objectives. To evaluate the push-out bond strength of experimental apatite calcium phosphate coated gutta-percha (HAGP) compared to different commercially available coated gutta-percha root obturation points. Methods. Extracted teeth were selected and instrumented using ProTaper rotary files. The canals were assigned into five equal groups and obturated using matching single cone technique as follows: EndoREZ cones and EndoREZ sealer, Bioceramic Endosequence gutta-percha (BCGP) with Endosequence BC sealer, Active GP with Endosequence BC sealer (ActiV GP), conventional GP with Endosequence BC sealer, and HAGP with Endosequence BC sealer. Each root was sectioned transversally at the thickness of 1±0.1 mm to obtain 5 sections (n=25 per group). The specimens were subjected to push-out test using a Universal Test Machine at a loading speed of 0.5 mm/ min. Failure modes after push-out test was examined under stereomicroscope and the push-out data were analyzed using ANOVA and the post hoc Dunnett T3 test (p = 0.05). Results. The highest mean bond strength was yielded by HAGP followed by BCGP, ActiV GP, conventional GP, and EndoREZ. There were significant differences between EndoREZ and all other groups (p<0.001). The prominent failure mode of HAGP was mixed mode, whereas EndoREZ exhibited adhesive failure mode. Conventional GP, ActiV GP, and BCGP showed cohesive failure mode. Conclusion. HAGP showed promising results to be used as root canal filling material in combination with bioceramic sealer.

1 December 2019 in Radiology Case Reports
Verified
Journal Article
Open access
MAMuhammad Khan Asif
Muhammad Khan Asif
PNPhrabhakaran Nambiar
Phrabhakaran Nambiar
IKIqra Muhammad Khan
Iqra Muhammad Khan
ZAZeti Adura Che Ab Aziz
Zeti Adura Che Ab Aziz
NNNora Sakina Binti Mohd Noor
Nora Sakina Binti Mohd Noor
NINorliza Ibrahim
Norliza Ibrahim
A patient was referred to the Oral and Maxillofacial Imaging Division and the attending dental specialist suspected a foreign object at the anterior region of the maxilla. The region was scanned using Kodak 9000 3D cone-beam computed tomography (CBCT) extraoral imaging system (Carestream Health, Inc.) to determine the type and morphometric characteristic of foreign object. The CBCT images failed to determine the identity and nature of the foreign object. CBCT images were then exported to the Materialise Interactive Medical Image Control System (Mimics) software to evaluate whether this software can help in enhancing the visualization of the foreign object in the maxillofacial region. The findings showed that there was an improved visualization of the foreign body and the type of the object could be determined with certainty. The object was identified as an endodontic file and was clearly visible when visualized as a reconstructed 3D model in Mimics software. Although the identification of abnormalities has been dramatically improved using 3D scans, the visualization can be further enhanced using image processing software like Mimics.

6 May 2015 in International Journal of Polymer Science
Verified
Journal Article
Open access
PDF file
AAAfaf Yahya Al-Haddad
Afaf Yahya Al-Haddad
MKMuralithran G. Kutty
Muralithran G. Kutty
NKNoor Hayaty Abu Kasim
Noor Hayaty Abu Kasim
ZAZeti Adura Che Ab Aziz
Zeti Adura Che Ab Aziz
Dental Gutta-percha (GP) is a polymer based standard root canal filling material that has been widely used in dentistry. However, it has an inadequate sealing ability and adhesion to root dentin. The aim of this study is to coat GP with a bioactive material to enhance its sealing ability and adhesion to the root sealer and subsequently to the root dentin. The choice of coating method is limited by the nature of GP as it requires a technique that is not governed by high temperatures or uses organic solvents. In this study, biomimetic coating technique using 1.5 Tas-simulated body fluids (SBF) was employed to coat the treated GP cones. The coated samples were characterized using Fourier transform infrared spectroscopy (FTIR), X-ray Diffraction (XRD), and field emission scanning electron microscope (FESEM). The presence of hydroxyl, carbonate, and phosphate groups was detected by FTIR while the formation of hydroxyapatite (HA)/calcium phosphate was confirmed with XRD. FESEM revealed uniform, thin, and crystalline HA calcium phosphate coating. The adhesion of the coating to the GP substrate was assessed with microscratch technique. It was viable with cohesive failure mode. In conclusion, Tas-SBF is able to coat pretreated GP cones with a crystalline apatitic calcium phosphate layer.

10 February 2022 in Journal of Pharmaceutical Research International
Verified
Journal Article
Open access
PDF file
AAAfaf Yahya Al-Haddad
Afaf Yahya Al-Haddad
MKMuralithran Govindan Kutty
Muralithran Govindan Kutty
ZAZeti Adura Che Ab Aziz
Zeti Adura Che Ab Aziz
Aims: This study aimed to assess the apical sealing ability of experimental apatite-coated gutta-percha points compared to various coated gutta-percha root filling materials. Study Design: Experimental in-vitro study. Place and Duration of Study: Department of Restorative Dentistry, University of Malaya, June 2014 and November 2014. Methodology: Ninety-six extracted permanent maxillary central incisors were standardized and prepared by ProTaper universal rotary files. The specimens were allocated into six groups (n=15) and filled using matching single cone technique as follows; EndoREZ points with EndoREZ sealer, Bioceramic coated points (BCGP), Active GP (ActiV GP), Conventional gutta-percha (GP), apatite coated GP (HAGP) all in combination with Endosequence BC sealer. The sixth group was filled using cold lateral compaction of Conventional GP and Endosequence BC sealer. The specimens were subjected to a dye leakage test. The remaining six teeth were divided equally to be used as a negative and positive control. One-way analysis of variance (ANOVA) followed by the post hoc Dunnett T3 test was performed for data analysis, and the significance value was set at P =.05. Results: ActiV GP had the least leakage followed by BCGP, HAGP, cold lateral compaction, conventional GP, and EndoRez. Conclusion: HAGP as root canal filling showed favourable sealing ability comparable to ActiV GP, BCGP, and conventional GP and it was superior to EndoREZ.

6 November 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NANoor Hayati Azami
Noor Hayati Azami
NNNora Sakina Mohd Noor
Nora Sakina Mohd Noor
AAAfaf Al-Haddad
Afaf Al-Haddad
RDRana Diab
Rana Diab
FMFauzi Majid
Fauzi Majid
ZAZeti Adura Che Ab Aziz
Zeti Adura Che Ab Aziz
This study evaluates the adhesive performance of a novel hydroxyapatite-coated gutta-percha (HAGP) in combination with various root canal sealers, using push-out bond strength testing and failure mode analysis. Eighty human single-canal teeth were divided into four groups: three test groups obturated with HAGP using AH Plus, iRoot SP, or GuttaFlow Bioseal, and one control group obturated with conventional gutta-percha (GP) with AH Plus sealer. Push-out bond strength was assessed after 30 days with a universal testing machine, and failure modes were analysed under stereomicroscopy. Results revealed a significantly higher bond strength (p < 0.001) for HAGP compared to the control, regardless of the sealer used. Failure analysis indicated 62.5% mixed failures and 37.5% cohesive failures, with no adhesive failure observed. These findings suggest that HAGP significantly improves gutta-percha adhesion, as demonstrated through the higher bond strength compared to conventional gutta-percha.

28 September 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
WAWael Ali Alawneh
Wael Ali Alawneh
ZAZeti Adura Che Ab Aziz
Zeti Adura Che Ab Aziz
HAHany Mohamed Aly Ahmed
Hany Mohamed Aly Ahmed
SMSelva Malar Munusamy
Selva Malar Munusamy
NINorliza Ibrahim
Norliza Ibrahim
MNMohamed Shady Nabhan
Mohamed Shady Nabhan
This investigation evaluated the efficiency of various root canal filling removal techniques in removing gutta-percha (GP) and iRoot SP sealer in mandibular premolars with long-oval shaped canal using micro-computed tomography (micro-CT). Forty-eight mandibular premolars with long oval canals were prepared using ProTaper Next to size X3 (30/0.06) and filled with gutta-percha and iRoot SP. The study samples were randomly divided into four groups based on removal technique ( n = 12 for each). Group 1 was Pro Taper Universal Retreatment system (PTU Rx), Group 2 was PTU Rx with Xylol, group 3 was PTU Rx with Endo Success Retreatment Kit, ET25 tip and the group 4 was PTU Rx with Xylol and ET25 tip of Endo Success Retreatment Kit. The study samples were scanned before and after the removal of the root canal filling material using a micro-CT. Kruskal–Wallis test with Benjamini–Hochberg control of the false discovery rate across outcomes and Dunn–Bonferroni post-hoc comparisons were used for data analysis ( P = 0.05). The findings revealed no significant differences among the tested groups regarding the amount of residual root filling material or the ability to regain apical patency ( P > 0.05). The apical third retained the greatest amount of filling remnants compared with the middle and coronal thirds ( P < 0.001). Overall, none of the retreatment techniques demonstrated superiority in removing calcium silicate based root filling materials from long oval canals. However, calcium silicate based sealers appear to be negotiable in single, straight root canals.