Stefano Presilla

Dr. Stefano Presilla

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2017 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
LBLuca Bellesi
Luca Bellesi
RWRolf Wyttenbach
Rolf Wyttenbach
DGDiego Gaudino
Diego Gaudino
PCPaolo Colleoni
Paolo Colleoni
FPFrancesco Pupillo
Francesco Pupillo
SPStefano Presilla
Stefano Presilla
The aim of this work was to evaluate detection of low-contrast objects and image quality in computed tomography (CT) phantom images acquired at different tube loadings (i.e. mAs) and reconstructed with different algorithms, in order to find appropriate settings to reduce the dose to the patient without any image detriment. Images of supraslice low-contrast objects of a CT phantom were acquired using different mAs values. Images were reconstructed using filtered back projection (FBP), hybrid and iterative model-based methods. Image quality parameters were evaluated in terms of modulation transfer function; noise, and uniformity using two software resources. For the definition of low-contrast detectability, studies based on both human (i.e. four-alternative forced-choice test) and model observers were performed across the various images. Compared to FBP, image quality parameters were improved by using iterative reconstruction (IR) algorithms. In particular, IR model-based methods provided a 60% noise reduction and a 70% dose reduction, preserving image quality and low-contrast detectability for human radiological evaluation. According to the model observer, the diameters of the minimum detectable detail were around 2 mm (up to 100 mAs). Below 100 mAs, the model observer was unable to provide a result. IR methods improve CT protocol quality, providing a potential dose reduction while maintaining a good image detectability. Model observer can in principle be useful to assist human performance in CT low-contrast detection tasks and in dose optimisation.

1 January 2021 in Physica Medica
Verified
Journal Article
Closed access
MCMargherita Casiraghi
Margherita Casiraghi
PSPietro Scarone
Pietro Scarone
LBLuca Bellesi
Luca Bellesi
MPMaria Antonietta Piliero
Maria Antonietta Piliero
FPFrancesco Pupillo
Francesco Pupillo
SPStefano Presilla
Stefano Presilla

1 October 2018 in Clinical Neurology and Neurosurgery
Verified
Journal Article
Closed access
EPEmanuele Pravatà
Emanuele Pravatà
SPStefano Presilla
Stefano Presilla
LRLuca Roccatagliata
Luca Roccatagliata
ACAlessandro Cianfoni
Alessandro Cianfoni

1 November 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
MPMaria Antonietta Piliero
Maria Antonietta Piliero
MCMargherita Casiraghi
Margherita Casiraghi
DBDavide Giovanni Bosetti
Davide Giovanni Bosetti
SCSimona Cima
Simona Cima
LDLetizia Deantonio
Letizia Deantonio
SPStefano Presilla
Stefano Presilla
Objective: To evaluate the performance of low dose cone beam CT (CBCT) acquisition protocols for image-guided radiotherapy of prostate cancer. Methods: CBCT images of patients undergoing prostate cancer radiotherapy were acquired with the settings currently used in our department and two low dose settings at 50% and 63% lower exposure. Four experienced radiation oncologists and two radiation therapy technologists graded the images on five image quality characteristics. The scores were analysed through Visual Grading Regression, using the acquisition settings and the patient size as covariates. Results: The low dose acquisition settings have no impact on the image quality for patients with body profile length at hip level below 100 cm. Conclusions: A reduction of about 60% of the dose is feasible for patients with size below 100 cm. The visibility of low contrast features can be compromised if using the low dose acquisition settings for patients with hip size above 100 cm. Advances in knowledge: Low dose CBCT acquisition protocols for the pelvis, based on subjective evaluation of patient images.

1 May 2023 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
MCMargherita Casiraghi
Margherita Casiraghi
MPMaria Antonietta Piliero
Maria Antonietta Piliero
LBLuca Bellesi
Luca Bellesi
MDMathieu Dufour
Mathieu Dufour
ACAnindita Chatterjea
Anindita Chatterjea
SPStefano Presilla
Stefano Presilla
PurposeUsing optimal settings for x-ray scans is crucial for obtaining three-dimensional images of high quality while keeping the patient dose low. Our work compares dose and image quality (IQ) of three intraoperative imaging systems [O-arm cone-beam computed tomography (CBCT), ClarifEye C-arm CBCT, and Airo computed tomography] used for spinal surgery.ApproachPatients of 70, 90, and 110 kg were simulated with an anthropomorphic phantom by adding tissue-equivalent material. Titanium inserts were placed in the phantom spine for reproducing metal artifacts in the images. Organ dose was measured with thermo-luminescent dosimeters for effective dose (E) calculation. Subjective IQ was assessed by ranking the images acquired with the manufacturer-defined imaging protocols. Objective IQ was assessed with a customized Catphan phantom.ResultsThe ClarifEye protocols resulted in the lowest E ranging from 1.4 to 5.1 mSv according to phantom size and protocol. The highest E was measured for the high-definition protocol of O-arm (E 2.2 to 9 mSv) providing the best subjective IQ for imaging of the spine without titanium inserts. For the images with metal, the best IQ was obtained with ClarifEye. Airo (E 5.5 to 8.4 mSv) was ranked with the lowest IQ for images without metal while the rank improved for images with metal. Airo images had better uniformity, noise, and contrast sensitivity compared with CBCTs but worse high-contrast resolution. The values of these parameters were comparable between the CBCT systems.ConclusionsBoth CBCT systems provided better IQ compared with Airo for navigation of lumbar spinal surgery for the original phantom. Metal artifacts particularly affect O-arm images decreasing the subjective IQ. The high spatial resolution of CBCT systems resulted in a relevant parameter for the visibility of anatomical features important for spine navigation. Low dose protocols were enough to obtain a clinically acceptable contrast-to-noise ratio in the bones.

16 September 2021 in Medical Dosimetry
Verified
Journal Article
Closed access
PDF file
MPMaria A. Piliero
Maria A. Piliero
FPFrancesco Pupillo
Francesco Pupillo
SLStefano Leva
Stefano Leva
MCMargherita Casiraghi
Margherita Casiraghi
EPEleonora Paulicelli
Eleonora Paulicelli
SPStefano Presilla
Stefano Presilla