Nguyen Thanh Phuoc

Nguyen Thanh Phuoc


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2018 in Polymers
Verified
Journal Article
Open access
PDF file
MPManivasagan Panchanathan
Manivasagan Panchanathan
SBSubramaniyan Bharathiraja
Subramaniyan Bharathiraja
SMSANTHAMOORTHY MADHAPPAN
SANTHAMOORTHY MADHAPPAN
SMSudip Mondal
Sudip Mondal
NPNguyen Thanh Phuoc
Nguyen Thanh Phuoc
JOJunghwan Oh
Junghwan Oh
Photothermal therapy (PTT) using biocompatible nanomaterials have recently attracted much attention as a novel candidate technique for cancer therapy. In this work we report the performance of newly synthesized multidentate chitosan oligosaccharide modified gold nanorods (AuNRs-LA-COS) as novel agents for PTT of cancer cells due to their excellent biocompatibility, photothermal stability, and high absorption in the near-infrared (NIR) region. The AuNRs-LA-COS exhibit a strong NIR absorption peak at 838 nm with a mean length of 26 ± 3.1 nm and diameter of 6.8 ± 1.7 nm, respectively. The temperature of AuNRs-LA-COS rapidly reached 52.6 °C for 5 min of NIR laser irradiation at 2 W/cm2. The AuNRs-LA-COS had very low cytotoxicity and exhibited high efficiency for the ablation of breast cancer cells in vitro. The tumor-bearing mice were completely ablated without tumor recurrence after photothermal treatment with AuNRs-LA-COS (25 µg/mL) under laser irradiation. In summary, this study demonstrated that AuNRs-LA-COS with laser irradiation as novel agents pave an alternative way for breast cancer therapy and hold great promise for clinical trials in the near future.

1 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NPNguyen Thanh Phuoc
Nguyen Thanh Phuoc
NTNguyen Thanh Phong Truong
Nguyen Thanh Phong Truong
NBNhat Quang Bui
Nhat Quang Bui
VNVan Tu Nguyen
Van Tu Nguyen
GHGiang Hoang
Giang Hoang
JOJunghwan Oh
Junghwan Oh
The present study illustrates the design, fabrication, and evaluation of a novel multifocal point (MFP) transducer based on polyvinylidene fluoride (PVDF) film for high-frequency ultrasound application. The fabricated MFP surface was press-focused using a computer numerical control (CNC) machining tool-customized multi-spherical pattern object. The multi-spherical pattern has five spherical surfaces with equal area and connected continuously to have the same energy level at focal points. Center points of these spheres are distributed in a linear pattern with 1 mm distance between each two points. The radius of these spheres increases steadily from 10 mm to 13.86 mm. The designed MFP transducer had a center frequency of 50 MHz and a −6 dB bandwidth of 68%. The wire phantom test was conducted to study and demonstrate the advantages of this novel design. The obtained results for MFP transducer revealed a significant increase (4.3 mm) of total focal zone in the near-field and far-field area compared with 0.48 mm obtained using the conventional single focal point transducer. Hence, the proposed method is promising to fabricate MFP transducers for deeper imaging depth applications.