David Schuster

Dr. David Schuster

orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
HAHamed Akbari
Hamed Akbari
LHLuma V. Halig
Luma V. Halig
DSDavid Schuster
David Schuster
AOAdeboye Osunkoya
Adeboye Osunkoya
VMViraj Master
Viraj Master
BFBaowei Fei
Baowei Fei
Hyperspectral imaging (HSI) is an emerging modality for various medical applications. Its spectroscopic data might be able to be used to noninvasively detect cancer. Quantitative analysis is often necessary in order to differentiate healthy from diseased tissue. We propose the use of an advanced image processing and classification method in order to analyze hyperspectral image data for prostate cancer detection. The spectral signatures were extracted and evaluated in both cancerous and normal tissue. Least squares support vector machines were developed and evaluated for classifying hyperspectral data in order to enhance the detection of cancer tissue. This method was used to detect prostate cancer in tumor-bearing mice and on pathology slides. Spatially resolved images were created to highlight the differences of the reflectance properties of cancer versus those of normal tissue. Preliminary results with 11 mice showed that the sensitivity and specificity of the hyperspectral image classification method are 92.8% to 2.0% and 96.9% to 1.3%, respectively. Therefore, this imaging method may be able to help physicians to dissect malignant regions with a safe margin and to evaluate the tumor bed after resection. This pilot study may lead to advances in the optical diagnosis of prostate cancer using HSI technology.

1 April 2005 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
APArnold C. Paulino
Arnold C. Paulino
MKMary Koshy
Mary Koshy
RHRebecca Howell
Rebecca Howell
DSDavid Schuster
David Schuster
LDLawrence W. Davis
Lawrence W. Davis

9 March 2015 in Nature Methods
Verified
Journal Article
Closed access
PSPhilip J Santangelo
Philip J Santangelo
KRKenneth A Rogers
Kenneth A Rogers
CZChiara Zurla
Chiara Zurla
EBEmmeline L Blanchard
Emmeline L Blanchard
SGSanjeev Gumber
Sanjeev Gumber
FVFrancois Villinger
Francois Villinger

1 March 2017 in Journal of Urology
Verified
Journal Article
Open access
TBTore Bach-Gansmo
Tore Bach-Gansmo
CNCristina Nanni
Cristina Nanni
PNPeter T. Nieh
Peter T. Nieh
LZLucia Zanoni
Lucia Zanoni
TBTronde Velde Bogsrud
Tronde Velde Bogsrud
FWFrode Willoch
Frode Willoch
Sensitive detection of cancer foci in men experiencing biochemical recurrence following initial treatment of prostate cancer is of great clinical significance with a possible impact on subsequent treatment choice. We describe a multisite experience of the efficacy and safety of the positron emission tomography/computerized tomography agent fluciclovine (18F) after biochemical recurrence. A total of 596 patients underwent fluciclovine (18F) positron emission tomography/computerized tomography at 4 clinical sites. Detection rate determinations were stratified by the baseline prostate specific antigen value. Diagnostic performance was assessed against a histological reference standard in 143 scans. The subject level fluciclovine (18F) positron emission tomography/computer tomography detection rate was 67.7% (403 of 595 scans). Positive findings were detected in the prostate/bed and pelvic lymph node regions in 38.7% (232 of 599) and 32.6% of scans (194 of 596), respectively. Metastatic involvement outside the pelvis was detected in 26.2% of scans (155 of 591). The subject level detection rate in patients in the lowest quartile for baseline prostate specific antigen (0.79 ng/ml or less) was 41.4% (53 of 128). Of these patients 13 had involvement in the prostate/bed only, 16 had pelvic lymph node involvement without distant disease and 24 had distant metastases. The positive predictive value of fluciclovine (18F) positron emission tomography/computerized tomography scanning for all sampled lesions was 62.2%, and it was 92.3% and 71.8% for extraprostatic and prostate/bed involvement, respectively. Fluciclovine (18F) was well tolerated and the safety profile was not altered following repeat administration. Fluciclovine (18F) is well tolerated and able to detect local and distant prostate cancer recurrence across a wide range of prostate specific antigen values.

1 May 2014 in Journal of Urology
Verified
Journal Article
Closed access
DSDavid Schuster
David Schuster
PNPeter T. Nieh
Peter T. Nieh
AJAshesh B. Jani
Ashesh B. Jani
RARianot Amzat
Rianot Amzat
FBF. DuBois Bowman
F. DuBois Bowman
MGMark M. Goodman
Mark M. Goodman
We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for prostate carcinoma recurrence. The former method detected significantly more prostatic and extraprostatic disease.

13 November 2014 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
DSDavid Schuster
David Schuster
CNCristina Nanni
Cristina Nanni
Stefano FantiStefano Fanti
Stefano Fanti
SOShuntaro Oka
Shuntaro Oka
HOHiroyuki Okudaira
Hiroyuki Okudaira
MGMark M. Goodman
Mark M. Goodman
Anti-1-amino-3-18F-fluorocyclobutane-1-carboxylic acid (18F-FACBC) is a synthetic amino acid analog PET radiotracer undergoing clinical trials for the evaluation of prostate and other cancers. We aimed to describe common physiologic uptake patterns, incidental findings, and variants in patients who had undergone 18F-FACBC PET. Methods: Sixteen clinical trials involving 611 18F-FACBC studies from 6 centers, which included dosimetry studies on 12 healthy volunteers, were reviewed. Qualitative observations of common physiologic patterns, incidental uptake, and variants that could simulate disease were recorded and compared with similar observations in studies of the healthy volunteers. Quantitative analysis of select data and review of prior published reports and observations were also made. Results: The liver and pancreas demonstrated the most intense uptake. Moderate salivary and pituitary uptake and variable mild to moderate bowel activity were commonly visualized. Moderate bone marrow and mild muscle activity were present on early images, with marrow activity decreasing and muscle activity increasing with time. Brain and lungs demonstrated activity less than blood pool. Though 18F-FACBC exhibited little renal excretion or bladder uptake during the clinically useful early imaging time window, mild to moderate activity might accumulate in the bladder and interfere with evaluation of adjacent prostate bed and seminal vesicles in 5%–10% of patients. Uptake might also occur from benign processes such as infection, inflammation, prostatic hyperplasia, and metabolically active benign bone lesions such as osteoid osteoma. Conclusion: Common physiologic uptake patterns were similar to those noted in healthy volunteers. The activity in organs followed the presence of amino acid transport and metabolism described with other amino acid–based PET radiotracers. As with other PET radiotracers such as 18F-FDG, focal nonphysiologic uptake may represent incidental malignancy. Uptake due to benign etiologies distinct from physiologic background also occurred and could lead to misinterpretations if the reader is unaware of them.