Prone posture increases cardiac output and improves pulmonary gas exchange. We hypothesized that, in the supine posture, greater compression of dependent lung limits regional blood flow. To test this, MRI-based measures of regional lung density, MRI arterial spin labeling quantification of pulmonary perfusion, and density-normalized perfusion were made in six healthy subjects. Measurements were made in both the prone and supine posture at functional residual capacity. Data were acquired in three nonoverlapping 15-mm sagittal slices covering most of the right lung: central, middle, and lateral, which were further divided into vertical zones: anterior, intermediate, and posterior. The density of the entire lung was not different between prone and supine, but the increase in lung density in the anterior lung with prone posture was less than the decrease in the posterior lung (change: +0.07 g/cm3 anterior, −0.11 posterior; P < 0.0001), indicating greater compression of dependent lung in supine posture, principally in the central lung slice ( P < 0.0001). Overall, density-normalized perfusion was significantly greater in prone posture (7.9 ± 3.6 ml·min−1·g−1 prone, 5.1 ± 1.8 supine, a 55% increase; P < 0.05) and showed the largest increase in the posterior lung as it became nondependent (change: +71% posterior, +58% intermediate, +31% anterior; P = 0.08), most marked in the central lung slice ( P < 0.05). These data indicate that central posterior portions of the lung are more compressed in the supine posture, likely by the heart and adjacent structures, than are central anterior portions in the prone and that this limits regional perfusion in the supine posture.
The structure of the lung, with its delicate network of airspaces and capillaries, means that gravity has a profound influence on its function. Studies of lung function in the absence of gravity provide valuable insight into how, for we Earth-bound individuals, its unavoidable effects shape our lung function. Gravity causes uneven ventilation in the lung through the deformation of lung tissue (the so-called Slinky effect), and uneven perfusion through a combination of the Slinky effect and the zone model of pulmonary perfusion. Both ventilation and perfusion exhibit persisting heterogeneity in microgravity, indicating important other mechanisms. However, gravity serves to maintain a degree of matching of these two processes, so that the ventilation/perfusion ratio, and thus gas exchange, remains efficient. Therefore, while both ventilation and perfusion are more uniform in spaceflight, gas exchange is seemingly no more efficient than on Earth. Despite the changes in lung function when gravity is removed, the lung continues to function well in weightlessness. Unlike many other organ systems, the lung does not appear to undergo structural adaptive changes when gravity is removed, and so there is no apparent degradation in lung function upon return to earth, even after 6 months in space.
Extended exposure to microgravity (μG) is known to reduce strength in weight-bearing muscles and was also reported to reduce respiratory muscle strength. Short- duration exposure to μG reduces vital capacity (VC), a surrogate measure for respiratory muscle strength, for the first few days, with little change in O2uptake, ventilation, or end-tidal partial pressures. Accordingly we measured VC, maximum inspiratory and expiratory pressures, and indexes of pulmonary gas exchange in 10 normal subjects (9 men, 1 woman, 39–52 yr) who lived on the International Space Station for 130–196 days in a normoxic, normobaric atmosphere. Subjects were studied four times in the standing and supine postures preflight at sea level at 1 G, approximately monthly in μG, and multiple times postflight. VC in μG was essentially unchanged compared with preflight standing [5.28 ± 0.08 liters (mean ± SE), n = 187; 5.24 ± 0.09, n = 117, respectively; P = 0.03] and considerably greater than that measured supine in 1G (4.96 ± 0.10, n = 114, P < 0.001). There was a trend for VC to decrease after the first 2 mo of μG, but there were no changes postflight. Maximum respiratory pressures in μG were generally intermediate to those standing and supine in 1G, and importantly they showed no decrease with time spent in μG. O2uptake and CO2production were reduced (∼12%) in extended μG, but inhomogeneity in the lung was not different compared with short-duration exposure to μG. The results show that VC is essentially unchanged and respiratory muscle strength is maintained during extended exposure to μG, and metabolic rate is reduced.
We measured the isocapnic hypoxic ventilatory response and the hypercapnic ventilatory response by using rebreathing techniques in five normal subjects (ages 37–47 yr) before, during, and after 16 days of exposure to microgravity (μG). Control measurements were performed with the subjects in the standing and supine postures. In both μG and in the supine position, the hypoxic ventilatory response, as measured from the slope of ventilation against arterial O2 saturation, was greatly reduced, being only 46 ± 10% (μG) and 52 ± 11% (supine) of that measured standing ( P < 0.01). During the hypercapnic ventilatory response test, the ventilation at a[ ] of 60 Torr was not significantly different in μG (101 ± 5%) and the supine position (89 ± 3%) from that measured standing. Inspiratory occlusion pressures agreed with these results. The findings can be explained by inhibition of the hypoxic but not hypercapnic drive, possibly as a result of an increase in blood pressure in carotid baroreceptors in μG and the supine position.
Although environmental physiologists are readily able to alter many aspects of the environment, it is not possible to remove the effects of gravity on Earth. During the past decade, a series of spaceflights were conducted in which comprehensive studies of the lung in microgravity (weightlessness) were performed. Stroke volume increases on initial exposure to microgravity and then decreases as circulating blood volume is reduced. Diffusing capacity increases markedly, due to increases in both pulmonary capillary blood volume and membrane diffusing capacity, likely due to more uniform pulmonary perfusion. Both ventilation and perfusion become more uniform throughout the lung, although much residual inhomogeneity remains. Despite the improvement in the distribution of both ventilation and perfusion, the range of the ventilation-to-perfusion ratio seen during a normal breath remains unaltered, possibly because of a spatial mismatch between ventilation and perfusion on a small scale. There are unexpected changes in the mixing of gas in the periphery of the lung, and evidence suggests that the intrinsic inhomogeneity of the lung exists at a scale of an acinus or a few acini. In addition, aerosol deposition in the alveolar region is unexpectedly high compared with existing models.