Peng Liu

Prof. Peng Liu

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
YHYawei Hu
Yawei Hu
XSXizhao Sui
Xizhao Sui
FSFan Song
Fan Song
YLYaqian Li
Yaqian Li
KLKaiyi Li
Kaiyi Li
PLPeng Liu
Peng Liu
While the potential of patient-derived organoids (PDOs) to predict patients’ responses to anti-cancer treatments has been well recognized, the lengthy time and the low efficiency in establishing PDOs hamper the implementation of PDO-based drug sensitivity tests in clinics. We first adapt a mechanical sample processing method to generate lung cancer organoids (LCOs) from surgically resected and biopsy tumor tissues. The LCOs recapitulate the histological and genetic features of the parental tumors and have the potential to expand indefinitely. By employing an integrated superhydrophobic microwell array chip (InSMAR-chip), we demonstrate hundreds of LCOs, a number that can be generated from most of the samples at passage 0, are sufficient to produce clinically meaningful drug responses within a week. The results prove our one-week drug tests are in good agreement with patient-derived xenografts, genetic mutations of tumors, and clinical outcomes. The LCO model coupled with the microwell device provides a technically feasible means for predicting patient-specific drug responses in clinical settings.

11 July 2014 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
WGWupeng Gan
Wupeng Gan
BZBin Zhuang
Bin Zhuang
PZPengfei Zhang
Pengfei Zhang
JHJunping Han
Junping Han
CLCai-Xia Li
Cai-Xia Li
PLPeng Liu
Peng Liu
A plastic microfluidic device that integrates a filter disc as a DNA capture phase was successfully developed for low-cost, rapid and automated DNA extraction and PCR amplification from various raw samples. The microdevice was constructed by sandwiching a piece of Fusion 5 filter, as well as a PDMS (polydimethylsiloxane) membrane, between two PMMA (poly(methyl methacrylate)) layers. An automated DNA extraction from 1 μL of human whole blood can be finished on the chip in 7 minutes by sequentially aspirating NaOH, HCl, and water through the filter. The filter disc containing extracted DNA was then taken out directly for PCR. On-chip DNA purification from 0.25–1 μL of human whole blood yielded 8.1–21.8 ng of DNA, higher than those obtained using QIAamp® DNA Micro kits. To realize DNA extraction from raw samples, an additional sample loading chamber containing a filter net with an 80 μm mesh size was designed in front of the extraction chamber to accommodate sample materials. Real-world samples, including whole blood, dried blood stains on Whatman® 903 paper, dried blood stains on FTA™ cards, buccal swabs, saliva, and cigarette butts, can all be processed in the system in 8 minutes. In addition, multiplex amplification of 15 STR (short tandem repeat) loci and Sanger-based DNA sequencing of the 520 bp GJB2 gene were accomplished from the filters that contained extracted DNA from blood. To further prove the feasibility of integrating this extraction method with downstream analyses, “in situ” PCR amplifications were successfully performed in the DNA extraction chamber following DNA purification from blood and blood stains without DNA elution. Using a modified protocol to bond the PDMS and PMMA, our plastic PDMS devices withstood the PCR process without any leakage. This study represents a significant step towards the practical application of on-chip DNA extraction methods, as well as the development of fully integrated genetic analytical systems.

8 March 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
WGWupeng Gan
Wupeng Gan
YGYin Gu
Yin Gu
JHJunping Han
Junping Han
CLCai-Xia Li
Cai-Xia Li
JSJing Sun
Jing Sun
PLPeng Liu
Peng Liu

23 April 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
ZGZhi Geng
Zhi Geng
SLShanglin Li
Shanglin Li
LZLingxiang Zhu
Lingxiang Zhu
Zhen ChengZhen Cheng
Zhen Cheng
MJMin Jin
Min Jin
PLPeng Liu
Peng Liu

12 June 2025 in Cell Stem Cell
Verified
Journal Article
Closed access
KLKaiyi Li
Kaiyi Li
CLChang Liu
Chang Liu
XSXizhao Sui
Xizhao Sui
CLChao Li
Chao Li
TZTing Zhang
Ting Zhang
PLPeng Liu
Peng Liu

14 August 2018 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JHJunhou Hui
Junhou Hui
YGYin Gu
Yin Gu
YZYuanshou Zhu
Yuanshou Zhu
YCYanjing Chen
Yanjing Chen
SGShu-Juan Guo
Shu-Juan Guo
PLPeng Liu
Peng Liu
A pipette-actuated capillary array comb (PAAC) system operated on a smartphone-based hand-held device has been successfully developed for the multiplex detection of bacteria in a “sample-to-answer” manner. The PAAC consists of eight open capillaries inserted into a cylindrical plastic base with a piece of chitosan-modified glass filter paper embedded in each capillary. During the sample preparation, a PAAC was mounted into a 1 mL pipette tip with an enlarged opening and was operated with a 1 mL pipette for liquid handling. The cell lysate was drawn and expelled through the capillaries three times to facilitate the DNA capture on the embedded filter discs. Following washes with water, the loop-mediated isothermal amplification (LAMP) reagents were aspirated into the capillaries, in which the primers were pre-fixed with chitosan. After that, the PAAC was loaded into the smartphone-based device for a one-hour amplification at 65 °C and end-point detection of calcein fluorescence in the capillaries. The DNA capture efficiency of a 1.1 mm-diameter filter disc was determined to be 97% of λ-DNA and the coefficient of variation among the eight capillaries in the PAAC was only 2.2%. The multiplex detection of genomic DNA extracted from Escherichia coli, Klebsiella pneumoniae, and Staphylococcus aureus provided limits of detection of 200, 500, and 500 copies, respectively, without any cross-contamination and cross reactions. “Sample-to-answer” detection of E. coli samples was successfully completed in 85 minutes, demonstrating a sensitivity of 200 cfu per capillary. The multiplex “sample-to-answer” detection, the streamlined operation, and the compact device should facilitate a broad range of applications of our PAAC system in point-of-care testing.