View All Publications
1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
YJYeseul Jo
Yeseul Jo
JKJeongJae Kim
JeongJae Kim
CPChul Hwan Park
Chul Hwan Park
JLJae Wook Lee
Jae Wook Lee
JHJee Hye Hur
Jee Hye Hur
HYHwanseok Yong
Hwanseok Yong
Cardiac magnetic resonance (CMR) imaging is widely used in many areas of cardiovascular disease assessment. This is a practical, standard CMR protocol for beginners that is designed to be easy to follow and implement. This protocol guideline is based on previously reported CMR guidelines and includes sequence terminology used by vendors, essential MR physics, imaging planes, field strength considerations, MRI-conditional devices, drugs for stress tests, various CMR modules, and disease/symptom-based protocols based on a survey of cardiologists and various appropriate-use criteria. It will be of considerable help in planning and implementing tests. In addressing CMR usage and creating this protocol guideline, we particularly tried to include useful tips to overcome various practical issues and improve CMR imaging. We hope that this document will continue to standardize and simplify a patient-based approach to clinical CMR and contribute to the promotion of public health.

1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
DIDong Jin Im
Dong Jin Im
SHSu Jin Hong
Su Jin Hong
EPEun-Ah Park
Eun-Ah Park
EKEun Young Kim
Eun Young Kim
YJYeseul Jo
Yeseul Jo
BLBae Young Lee
Bae Young Lee
This document is the third part of the guidelines for the protocol, the interpretation and post-processing of cardiac magnetic resonance (CMR) studies. These consensus recommendations have been developed by the Consensus Committee of the Korean Society of Cardiovascular Imaging to standardize the requirements for image interpretation and post-processing of CMR. This third part of the recommendations describes tissue characterization modules, including perfusion, late gadolinium enhancement, and T1- and T2 mapping. Additionally, this document provides guidance for visual and quantitative assessment consisting of "What-to-See," "How-To," and common pitfalls for the analysis of each module. The Consensus Committee hopes that this document will contribute to the standardization of image interpretation and post-processing of CMR studies.

1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
JLJae Wook Lee
Jae Wook Lee
JHJee Hye Hur
Jee Hye Hur
DYDong Hyun Yang
Dong Hyun Yang
BLBae Young Lee
Bae Young Lee
DIDong Jin Im
Dong Jin Im
HYHwanseok Yong
Hwanseok Yong
Cardiovascular magnetic resonance imaging (CMR) is expected to be increasingly used in Korea due to technological advances and the expanded national insurance coverage of CMR assessments. For improved patient care, proper acquisition of CMR images as well as their accurate interpretation by well-trained personnel are equally important. In response to the increased demand for CMR, the Korean Society of Cardiovascular Imaging (KOSCI) has issued interpretation guidelines in conjunction with the Korean Society of Radiology. KOSCI has also created a formal Committee on CMR guidelines to create updated practices. The members of this committee review previously published interpretation guidelines and discuss the patterns of CMR use in Korea.

11 June 2023 in Medicina
Verified
Journal Article
Open access
PDF file
DKDuk Ju Kim
Duk Ju Kim
In Chul NamIn Chul Nam
In Chul Nam
SPSung-Eun Park
Sung-Eun Park
DKDoo Ri Kim
Doo Ri Kim
JLJeong-Sub Lee
Jeong-Sub Lee
JWJung Ho Won
Jung Ho Won
Background and Objectives: This study aimed to evaluate the added value of cone-beam computed tomography (CBCT) for detecting hepatocellular carcinomas (HCC) and feeding arteries during transcatheter arterial chemoembolization (TACE). Material and methods: Seventy-six patients underwent TACE and CBCT. We subcategorized patients into groups I (61 patients: possible superselection of tumor/feeding arteries) and II (15 patients: limited superselection of tumor/feeding arteries). We evaluated fluoroscopy time and radiation dose during TACE. Two blinded radiologists independently performed an interval reading based on digital subtraction angiography (DSA) imaging only and DSA combined with CBCT in group I. Result: The mean total fluoroscopy time was 1456.3 ± 605.6 s. The mean dose–area product (DAP), mean DAP of CBCT, and mean ratio of DAP of CBCT to total DAP was 137.1 ± 69.2 Gy cm2, 18.3 ± 7.1 Gy cm2, and 13.3%, respectively. The sensitivity for detecting HCC increased after the additional CBCT reading, from 69.6% to 97.3% and 69.6% to 96.4% for readers 1 and 2, respectively. The sensitivity for detecting feeding arteries increased from 60.3% to 96.6% and 63.8% to 97.4% for readers 1 and 2, respectively. Conclusions: CBCT can increase sensitivity for detecting HCCs and feeding arteries without significantly increasing the radiation exposure.

23 May 2022 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
SLSang Hoon Lee
Sang Hoon Lee
JLJeong Sub Lee
Jeong Sub Lee
JKJeongJae Kim
JeongJae Kim
SKSu Yeon Ko
Su Yeon Ko
KLKyung Ryeol Lee
Kyung Ryeol Lee
CHChang Lim Hyun
Chang Lim Hyun
이상훈, et al. J Korean Soc Radiol. 2022 May;83:e50. https://doi.org/10.3348/jksr.2021.0172

4 November 2021 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
JCJaesung Cho
Jaesung Cho
JKJeongJae Kim
JeongJae Kim
SJSun Young Jeong
Sun Young Jeong
YLYun Soo Lee
Yun Soo Lee
MKMiok Kim
Miok Kim
MKMyeong Ju Koh
Myeong Ju Koh
조재성, et al. J Korean Soc Radiol. 2021 Nov;82:e155. https://doi.org/10.3348/jksr.2021.0091