Sentinel lymph node (SLN) mapping has been investigated as part of surgical staging in women with early-stage cervical cancer (CC); however, pelvic lymphadenectomy (PLND) remains the standard of care. This study aimed to assess feasibility and safety of SLN detection using superparamagnetic iron oxide (SPIO) nanoparticles as a tracer in CC. Thirty CC patients presumed to be stage I were included in this study with SPIO administered intracervically as a tracer for SLN mapping using a magnetometer and followed by PLND. The endpoints of the study included the proportion of successful SLN detection, the average number of SLNs per patient, and the proportion of pathologically positive results per patient and per node. The diagnostic accuracy of SPIO nanoparticles for detection of metastatic SLNs was evaluated by Receiver Operating Characteristic (ROC) curve analysis, with the area under the ROC curve (AUC) used to demonstrate the studied method’s sensitivity. Safety endpoints were a summary of all reported adverse events. SLNs were detected in all cases, bilaterally in 27 patients (90%). The median number of SLNs per patient was 3.5. Four cases had metastatic SLNs. The general malignancy rate per patient was 13.3%, and per node, it was 0.8%. The malignancy detection rate of SLNs was 100% per patient and 80% per node. The AUC of 1.0 (p < 0.001) confirmed the diagnostic value of the SPIO technique for the detection of metastatic SLNs, with a sensitivity of 100%. No adverse events related to the SPIO administration were reported. SPIO nanoparticles, as a tracer for SLN mapping in early-stage CC patients, demonstrated satisfactory accuracy parameters and safety; however, these data need to be evaluated by further research.
Background: Radioactive colloids are considered the standard of care for sentinel lymph node (SLN) detection. An alternative detection method using superparamagnetic iron oxide (SPIO) nanoparticles is well documented in breast cancer but poorly studied for gynecological tumors, including vulvar cancer (VC). Objective: Our aim was to evaluate the feasibility, accuracy, and safety of SPIO nanoparticles for SLN mapping in patients with VC as a stand-alone technique compared with the combination of two methods: the standard of care using a radioactive isotope (technetium-99; Tc-99) and SPIO as a new tracer. Methods: We conducted a prospective and observational study of SLN mapping in patients with stage IB VC and tumor size ≤ 4 cm. We calculated detection and malignancy rates per patient and per groin in both study groups. During the 36-month follow-up, the groin recurrence rate was estimated for positive and negative SLNs. Kaplan–Meyer curves were used to analyze the probability of survival, depending on disease-free survival. Results: A total of 110 groins assessed by SLN in 60 patients included in this study were analyzed (70 groins from 40 patients in the group with a single tracer and 40 groins from 20 patients in the group of combined tracers). At least one sentinel lymph node was detected in every patient while the bilateral detection rate was 92.3% for the SPIO group and 88.2% for the Tc-99 and SPIO group. The groin detection rate was 94.3% and 90%, respectively. SLN mapping failure was similar in both groups (2.8% and 2.5%, respectively). During a 3-year follow-up, the isolated groin recurrence rate was 2.1% for negative groins and for disease-free survival it was 28.9 months in the combined tracer group versus 32.8 months in the SPIO group. The Kaplan–Meyer curves showed the increased probability of survival for the SPIO group (87.5%); however, it was insignificant. Conclusions: SLN mapping using the SPIO technique in patients with VC is non-inferior to the combined SPIO and Tc-99 method.