Rifat Ara Rouf

Dr. Rifat Ara Rouf

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2018 in Heat Transfer Engineering
Verified
Journal Article
Closed access
RRRifat Ara Rouf
Rifat Ara Rouf
KAK. C. Amanul Alam
K. C. Amanul Alam
BSBidyut Baran Saha
Bidyut Baran Saha
K M Ariful KabirK M Ariful Kabir
K M Ariful Kabir
Conventional solar heat-driven single stage two bed chillers demand a large area for installation of solar thermal collector to activate the chiller, but in a highly populated tropical country open spaces is insufficient. In the intention to utilize accessible solar energy with better performance, a mathematical investigation is carried out with a three bed adsorption cooling unit working with silica gel-water pair. The studied chiller is powered by direct solar heat collected by a series of compound parabolic concentrator solar thermal collectors without any heat or mass recovery. The working principal of the chiller is, in principle, the same as the conventional two-bed adsorption chiller. However, instead of two half cycles, there are three one third cycles in the proposed chiller in which at every cycle the former desorber is kept in the precooling mode and as an adsorber for the next two one third cycles, respectively. As desorption kinetic is faster than the adsorption kinetics, this longer precooling mode helps the silica gel granules to adsorb more water molecules and increase evaporation rate. Hence, a better cooling effect of at least 1°C can be observed, increases chiller working hour after sunset for almost a further one hour.

1 November 2015 in Energy Procedia
Verified
Journal Article
Open access
K M Ariful KabirK M Ariful Kabir
K M Ariful Kabir
KAK.C. Amanul Alam
K.C. Amanul Alam
MSM.M.A. Sarker
M.M.A. Sarker
RRRifat Ara Rouf
Rifat Ara Rouf
BSBidyut Baran Saha
Bidyut Baran Saha
The study investigates the effect of mass recovery process on the performance of a conventional two bed solar adsorption cooling system with direct solar coupling mathematically. In an adsorption refrigeration system, the pressure in adsorber and desorber are different. The mass recovery scheme utilizes this pressure difference to enhance the refrigerant mass circulation. Average Cooling Capacity (ACC) and Coefficient of Performance (COP) were calculated by computer simulation to analyze the influences of operating conditions. The results show that the average cooling capacity of mass recovery system is superior to that of conventional system. It is also seen that mass recovery process enhances the overall performances of solar driven chiller and there is an optimum mass recovery time for an adsorption cooling system with direct solar couplin

1 January 2013 in Procedia Engineering
Verified
Journal Article
Open access
RRRifat Ara Rouf
Rifat Ara Rouf
KAK. C. Amanul Alam
K. C. Amanul Alam
MKM. A. Hakim Khan
M. A. Hakim Khan
Adsorption solar cooling appears to have prospect in the tropical countries. The present study investigates the effect of operating conditions on the performance of solar powered adsorption chiller for the climatic condition of Dhaka (Latitude 23 46 N, Longitude 90 23 E). A set of mathematical equations has been utilized to investigate the performance of the system numerically. Based on the solar radiation data, it is seen that at least 13 collectors (each of area 2.42 m2) are essential to achieve the required heat source temperature in the hot and humid months. It appeared during the investigation that the unit provides the cooling capacity around 10 kW at noon with base run conditions, while the system provide the solar COP around 0.35. As the cycle time has a major effect on heat source temperature as well as on system performance, it is observed that there is an optimum cycle time for the collector size. Also, the performance of the chiller can be improved by controlling the chilled water flow rates. Therefore, it may be concluded that the collector size may be reduced by setting the optimum cycle time and the chilled water flow rate

1 December 2008
Verified
Conference Paper
Closed access
SBShipra Banik
Shipra Banik
FCFarah Habib Chanchary
Farah Habib Chanchary
KKKhodadad Khan
Khodadad Khan
RRRifat Ara Rouf
Rifat Ara Rouf
MAMohammed Anwer
Mohammed Anwer
True information about rainfall is crucial for human activities such as the use and the management of water resources, hydroelectric power projects, warning to impend droughts or floods, urban areas sewer systems and many others. This paper investigates the development of an efficient model to forecast monthly monsoon rainfall for a number of stations, namely Barishal, Chittagong, Dhaka, Khulna, Rajshahi and Sylhet. It is believed that rainfall forecasting is difficult and also a challenging task for anyone because rainfall data are multi-dimensional and nonlinear. Therefore, to model rainfall data, the AI models, namely artificial neural network (ANN), adaptive neuro fuzzy inference system (ANFIS) and genetic algorithm (GA) have been used. Results found by the AI models are also compared to the linear regression model to show advantages of selecting these models. Findings suggest that ANFIS and GA approaches could be used more accurately than the other two selected approaches to forecast the Bangladeshi monsoon rainfall.

1 January 2014 in Procedia Engineering
Verified
Journal Article
Open access
RRRifat Ara Rouf
Rifat Ara Rouf
KAK.C. Amanul Alam
K.C. Amanul Alam
MKM.A. Hakim Khan
M.A. Hakim Khan
BSBidyut Baran Saha
Bidyut Baran Saha
FMF. Meunier
F. Meunier
K M Ariful KabirK M Ariful Kabir
K M Ariful Kabir

16 November 2015 in Heat Transfer Engineering
Verified
Journal Article
Closed access
KAK. C. Amanul Alam
K. C. Amanul Alam
RRRifat Ara Rouf
Rifat Ara Rouf
BSBidyut Baran Saha
Bidyut Baran Saha
MKM. Abdul Hakim Khan
M. Abdul Hakim Khan
FMFrancis Meunier
Francis Meunier