Kevin Webb

Prof. Kevin Webb

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2011 in The Journal of Immunology
Verified
Journal Article
Open access
PDF file
AMAriadna Mendoza-Naranjo
Ariadna Mendoza-Naranjo
GBGerben Bouma
Gerben Bouma
CPCristián Pereda
Cristián Pereda
MRMarcos Ramírez
Marcos Ramírez
KWKevin Webb
Kevin Webb
FSFlavio Salazar-Onfray
Flavio Salazar-Onfray
Gap junction (GJ) mediates intercellular communication through linked hemichannels from each of two adjacent cells. Using human and mouse models, we show that connexin 43 (Cx43), the main GJ protein in the immune system, was recruited to the immunological synapse during T cell priming as both GJs and stand-alone hemichannels. Cx43 accumulation at the synapse was Ag specific and time dependent, and required an intact actin cytoskeleton. Fluorescence recovery after photobleaching and Cx43-specific inhibitors were used to prove that intercellular communication between T cells and dendritic cells is bidirectional and specifically mediated by Cx43. Moreover, this intercellular cross talk contributed to T cell activation as silencing of Cx43 with an antisense or inhibition of GJ docking impaired intracellular Ca2+ responses and cytokine release by T cells. These findings identify Cx43 as an important functional component of the immunological synapse and reveal a crucial role for GJs and hemichannels as coordinators of the dendritic cell–T cell signaling machinery that regulates T cell activation.

20 December 2016 in Scientific Reports
Verified
Journal Article
Open access
FPFernando Pérez-Cota
Fernando Pérez-Cota
RSRichard J. Smith
Richard J. Smith
EMEmilia Moradi
Emilia Moradi
LMLeonel Marques
Leonel Marques
KWKevin Webb
Kevin Webb
MCMatt Clark
Matt Clark
Label-free imaging of living cells below the optical diffraction limit poses great challenges for optical microscopy. Biologically relevant structural information remains below the Rayleigh limit and beyond the reach of conventional microscopes. Super-resolution techniques are typically based on the non-linear and stochastic response of fluorescent labels which can be toxic and interfere with cell function. In this paper we present, for the first time, imaging of live cells using sub-optical wavelength phonons. The axial imaging resolution of our system is determined by the acoustic wavelength (λa = λprobe/2n) and not on the NA of the optics allowing sub-optical wavelength acoustic sectioning of samples using the time of flight. The transverse resolution is currently limited to the optical spot size. The contrast mechanism is significantly determined by the mechanical properties of the cells and requires no additional contrast agent, stain or label to image the cell structure. The ability to breach the optical diffraction limit to image living cells acoustically promises to bring a new suite of imaging technologies to bear in answering exigent questions in cell biology and biomedicine.

28 September 2015 in Applied Optics
Verified
Journal Article
Closed access
PDF file
FPFernando Pérez-Cota
Fernando Pérez-Cota
RSRichard J. Smith
Richard J. Smith
EMEmilia Moradi
Emilia Moradi
LMLeonel Marques
Leonel Marques
KWKevin Webb
Kevin Webb
MCMatt Clark
Matt Clark
At low frequencies ultrasound is a valuable tool to mechanically characterize and image biological tissues. There is much interest in using high-frequency ultrasound to investigate single cells. Mechanical characterization of vegetal and biological cells by measurement of Brillouin oscillations has been demonstrated using ultrasound in the GHz range. This paper presents a method to extend this technique from the previously reported single-point measurements and line scans into a high-resolution acoustic imaging tool. Our technique uses a three-layered metal-dielectric-metal film as a transducer to launch acoustic waves into the cell we want to study. The design of this transducer and measuring system is optimized to overcome the vulnerability of a cell to the exposure of laser light and heat without sacrificing the signal-to-noise ratio. The transducer substrate shields the cell from the laser radiation, efficiently generates acoustic waves, facilitates optical detection in transmission, and aids with heat dissipation away from the cell. This paper discusses the design of the transducers and instrumentation and presents Brillouin frequency images on phantom, fixed, and living cells.

1 February 2009 in Experimental Eye Research
Verified
Journal Article
Closed access
Paul James DonaldsonPaul James Donaldson
Paul James Donaldson
KCKaa-Sandra N. Chee
Kaa-Sandra N. Chee
JLJulie C. Lim
Julie C. Lim
KWKevin Webb
Kevin Webb

28 October 2020 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
FPFernando Pérez-Cota
Fernando Pérez-Cota
RFRafael Fuentes-Dominguez
Rafael Fuentes-Dominguez
SCSalvatore La Cavera
Salvatore La Cavera
WHWilliam Hardiman
William Hardiman
MYMengting Yao
Mengting Yao
MCMatt Clark
Matt Clark
Characterization of the elasticity of biological cells is growing as a new way to gain insight into cell biology. Cell mechanics are related to most aspects of cellular behavior, and applications in research and medicine are broad. Current methods are often limited since they require physical contact or lack resolution. From the methods available for the characterization of elasticity, those relying on high frequency ultrasound (phonons) are the most promising because they offer label-free, high (even super-optical) resolution and compatibility with conventional optical microscopes. In this Perspective contribution, we review the state of the art of picosecond ultrasonics for cell imaging and characterization, particularly for Brillouin scattering-based methods, offering an opinion for the challenges faced by the technology. The challenges are separated into biocompatibility, acquisition speed, resolution, and data interpretation and are discussed in detail along with new results.

3 August 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
FPFlavius C. Pascut
Flavius C. Pascut
VCValentin Couvreur
Valentin Couvreur
DDDaniela Dietrich
Daniela Dietrich
NLNicky Leftley
Nicky Leftley
GRGuilhem Reyt
Guilhem Reyt
KWKevin Webb
Kevin Webb
A key impediment to studying water-related mechanisms in plants is the inability to non-invasively image water fluxes in cells at high temporal and spatial resolution. Here, we report that Raman microspectroscopy, complemented by hydrodynamic modelling, can achieve this goal - monitoring hydrodynamics within living root tissues at cell- and sub-second-scale resolutions. Raman imaging of water-transporting xylem vessels in Arabidopsis thaliana mutant roots reveals faster xylem water transport in endodermal diffusion barrier mutants. Furthermore, transverse line scans across the root suggest water transported via the root xylem does not re-enter outer root tissues nor the surrounding soil when en-route to shoot tissues if endodermal diffusion barriers are intact, thereby separating ‘two water worlds’.