Zengxiang Zhou

Dr. Zengxiang Zhou

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Closed access
PDF file
FZFeifan Zhang
Feifan Zhang
JWJianping Wang
Jianping Wang
CZChao Zhai
Chao Zhai
Yi JinYi Jin
Yi Jin
ZLZhigang Liu
Zhigang Liu
ZZZengxiang Zhou
Zengxiang Zhou
<!-- *** Custom HTML *** --> Multiobject spectroscopy is applied in numerous modern astronomical facilities conducting observations of a large number of targets per pointing. Assigning the maximum number of targets to these instruments requires efficient algorithms. We present a simple and effective algorithm, the averaging (Aver) algorithm, to maximize the number of assigned targets for the first few visits of a given field. In comparison to the draining (Dra) algorithm, our algorithm increases the target completeness by 1% to 2% by employing Poisson distributed and real catalogs from the Large Sky Area Multiobject Fiber Spectroscopic Telescope survey. Moreover, our algorithm performs ∼375 times faster than the conventionally applied simulated annealing algorithm and yields a slightly higher completeness. We further optimize the Aver and Dra algorithms by combining the genetic algorithm (GA) and the differential evolution method. The Aver is slightly optimized by this method, whereas the Dra algorithm is improved by 0.9% to 1.6%, suggesting that our proposed Aver algorithm approaches maximum completeness. Furthermore, we find that the GA can optimize the rotation angle with a specially designed fitness function in the case of focal-plane rotation that is expected to be realized in the future, achieving a 1.8% increase in the number of the targets observed. In particular, our Aver algorithm assigns the maximum number of targets within the first few visits.

1 November 2021 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
MZMing Zhou
Ming Zhou
GLGuanru Lv
Guanru Lv
JLJian Li
Jian Li
ZZZengxiang Zhou
Zengxiang Zhou
ZLZhigang Liu
Zhigang Liu
Haotong ZhangHaotong Zhang
Haotong Zhang
The double revolving fiber positioning unit (FPU) is one of the key technologies of The Large Sky Area Multi-Object Fiber Spectroscope Telescope (LAMOST). The positioning accuracy of the computer controlled FPU depends on robot accuracy as well as the initial parameters of FPU. These initial parameters may deteriorate with time when FPU is running in non-supervision mode, which would lead to bad fiber position accuracy and further efficiency degradation in the subsequent surveys. In this paper, we present an algorithm based on deep learning to detect the FPU’s initial angle using the front illuminated image of LAMOST focal plane. Preliminary test results show that the detection accuracy of the FPU initial angle is better than 2.°5, which is good enough to distinguish those obvious bad FPUs. Our results are further well verified by direct measurement of fiber position from the back illuminated image and the correlation analysis of the spectral flux in LAMOST survey data.

1 February 2022 in Research in Astronomy and Astrophysics
Verified
Journal Article
Closed access
SDShi-Peng Duan
Shi-Peng Duan
ZZZengxiang Zhou
Zengxiang Zhou
JZJia-Le Zuo
Jia-Le Zuo
MLMeng-Tao Li
Meng-Tao Li
ZLZhi-Gang Liu
Zhi-Gang Liu
HZHao-Tong Zhang
Hao-Tong Zhang
To date, the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) has been in operation for 12 yr. To improve the telescope's astronomical observation accuracy, the original open-loop fiber positioning system of LAMOST is in urgent need of upgrading. The upgrade plan is to install several fiber view cameras (FVCs) around primary mirror B to build a closed-loop feedback control system. The FVCs are 20 m from the focal surface. To reduce a series of errors when the cameras detect the positions of the optical fibers, we designed fiducial fibers on the focal surface to be fiducial points for the cameras. Increasing the number of fiducial fibers can improve the detection accuracy of the FVC system, but it will also certainly reduce the number of fiber positioners that can be used for observation. Therefore, the focus of this paper is how to achieve the quantity and distribution that meet the requirements of system detection. In this paper, we introduce the necessity of using fiducial fibers, propose a method for selecting their number and present several methods for assessing the uniformity of their distribution. Finally, we implement particle swarm optimization to find the best distribution of fiducial fibers.

1 November 2022 in Publications of the Astronomical Society of the Pacific
Verified
Journal Article
Closed access
SDShipeng Duan
Shipeng Duan
JLJiadong Liang
Jiadong Liang
ZCZeyu Cai
Zeyu Cai
ZLZhigang Liu
Zhigang Liu
HHHongzhuan Hu
Hongzhuan Hu
ZZZengxiang Zhou
Zengxiang Zhou
To obtain the world coordinates of a measured object in camera measurement, a certain number of image control points should be established around the detected object as fiducial points for data processing. The precision of a fiducial point directly determines the measurement accuracy of the measured object in the camera measurement. Fiducial points in camera measurement are widely used in various fields of measurement, such as aerial surveys, close-range surveys, and 3D reconstruction. In addition, a fiducial point generally adopts an encoding structure to reduce the search cost in the detection. Camera measurement is used in the LAMOST fiber positioning system, which also requires fiducial points to ensure the accuracy of fiber positioning. Different from a general fiducial point, the whole system needs to operate under dark conditions during LAMOST observation, and optical fiber positioning is carried out by the “backlighting method”, which measures the optical fiber spot under a dark background. In addition, fiber positioning needs to reach an accuracy of 40 μm at a distance of 20 m, which is difficult to achieve with the fiducial points used in general vision measurements. To meet the requirements of LAMOST optical fiber positioning with high accuracy, this paper presents a fiducial fiber and its recognition algorithm for optical fiber positioning of optical fiber spectroscopic telescopes. The fiducial fiber can be applied to a wide-field optical fiber spectroscopic telescope measurement system in a high-precision long-distance measurement environment. The experimental results show that fiducial fiber can ensure the accuracy of closed-loop positioning for LAMOST fiber units.

1 January 2021 in Journal of Astronomical Telescopes, Instruments, and Systems
Verified
Journal Article
Closed access
PDF file
ZZZengxiang Zhou
Zengxiang Zhou
SDShipeng Duan
Shipeng Duan
JZJiale Zuo
Jiale Zuo
MLMengtao Li
Mengtao Li
ZLZhigang Liu
Zhigang Liu
JCJiaru Chu
Jiaru Chu
<!-- *** Custom HTML *** --> Fiber positioning technology is widely used in spectroscopic telescopes, and the accurate identification of the fiber position on the focal plane directly affects the efficiency of the astronomical spectrum. At present, fiber positioning usually uses the “back-illuminate” technique to illuminate one end of the fiber. The other end of the fiber is used for detection. The fiber could be stressed or twisted during locator motion, resulting in a difference between the detected fiber position and the actual fiber core. However, the fiber-optic back-illuminated device in the spectrometer system increases the complexity of the system and the time loss of fiber positioning. This paper attempts to use a new method combining image processing with deep learning to identify the fiber ferrule by the front-illuminated method. We built an experimental platform in the lab and experimented with a CMOS camera and telecentric lens. We tested the repeated errors and displacement measurement errors of the two methods. A series of comparative experimental results show that the final detection accuracy of this method can meet the needs of optical fiber positioning in the laboratory, although it has not yet reached the accuracy of the back-illuminated approach. In the future, if the light source and fiber ferrule were specifically designed for the front-illuminated method, its accuracy could be further improved.

15 February 2022
Verified
Conference Paper
Closed access
PDF file
ZPZhi Pan
Zhi Pan
YWYinJie Wu
YinJie Wu
ZLZhigang Liu
Zhigang Liu
ZZZengxiang Zhou
Zengxiang Zhou
With the development of optical fiber positioning, the LAMOST (Large Sky Area Multi-Object Fiber Spectroscopy Telescope) system requires higher positioning accuracy. Despite the great success of open-loop control mode in previous techniques, it would be hard to meet the strict requirements of the next-generation optical fiber positioning techniques. In contrast to the open-loop system, in this paper, we focus on the closed-loop control of fiber positioning based on visual measurement. In our proposed framework, by measuring the actual position of the optical fiber positioner and feeding it back to the control system, we control the positioner to approach the target position multiple times to improve the accuracy of optical fiber positioning. Nevertheless, the challenges such as cross-border phenomenon and collision of the fiber positioner still hinder the accuracy of our designed system. To tackle the former challenge, we normalize the central axis angle of the positioner according to the algorithm we proposed, which alleviates the problem that the positioner cannot move successfully due to the cross-border phenomenon near the mechanical zero position in the central axis. Extensive experimental results show that closed-loop control consistently improves the positioning accuracy of the unit. After ignoring the lens positioning error, 95% fiber unit positioning error under our proposed closed-loop control method is less than 40um after three steps of approximation, 98% fiber unit positioning error is less than 40um after four steps of approximation, which meets the requirements of high precision fiber positioning. It is worth noting that our experiments also exhibit the insensitivity of the closed-loop positioning scheme to the initial unit parameters, verifying the satisfactory robustness of our proposed method.