Purpose: The purpose of this clinical feasibility study was to evaluate the applicability of magnetic resonance imaging (MRI) for the assessment of apical periodontitis in direct comparison with cone beam CT (CBCT). Materials and Methods: 19 consecutive patients (average age 43 ± 13 years) with 34 lesions in total (13 molars, 14 premolars and 7 front teeth) were enrolled in this feasibility study. Periapical lesions were defined as periapical radiolucencies (CBCT) or structural changes in the spongy bone signal (MRI), which were connected with the apical part of a root and with at least twice the width of the periodontal ligament space. The location and dimension of the lesions were compared between MRI and CBCT. Results: While mainly mineralized tissue components such as teeth and bone were visible with CBCT, complimentary information of the soft tissue components was assessable with MRI. The MRI images provided sufficient diagnostic detail for the assessment of the main structures of interest. Heterogeneous contrast was observed within the lesion, with often a clear enhancement close to the apical foramen and the periodontal gap. No difference for lesion visibility was observed between MRI and CBCT. The lesion dimensions corresponded well, but were slightly but significantly overestimated with MRI. A heterogeneous lesion appearance was observed in several patients. Four patients presented with a well circumscribed hyperintense signal in the vicinity of the apical foramen. Conclusion: The MRI capability of soft tissue characterization may facilitate detailed analysis of periapical lesions. This clinical study confirms the applicability of multi-contrast MRI for the identification of periapical lesions. Key Points: • MRI can be applied for the identification of periapical lesions without ionizing radiation exposure • MRI might facilitate more detailed characterization of periapical lesions • MRI might provide more accurate lesion dimensions as X-ray-based methods Citation Format: • Geibel MA., Schreiber ES, Bracher AK et al. Assessment of Apical Periodontitis by MRI: A Feasibility Study. Fortschr Röntgenstr 2015; 187: 269 – 275 Ziel: Das Ziel dieser klinischen Machbarkeitsstudie war die Untersuchung der Darstellbarkeit periapikaler Osteolysen mittels der Magnetresonanztomografie (MRT) im direkten Vergleich mit der digitalen Volumentomografie (DVT). Material und Methoden: In die Studie wurden 19 Patienten (Durchschnittsalter 43 ± 13 Jahre) mit 34 periapikalen Osteolysen eingeschlossen. Die Läsionen wurden radiologisch befundet als periapikale Osteolysen (DVT) oder als knöcherne Destruktion in der Spongiosa (MRT), die eine Lagebeziehung zum Apex des Wurzelkanals hatten und mindestens eine Ausdehnung der zweifachen Größe des parodontalen Ligaments zeigten. Zur Auswertung kamen die Lage der Läsion und deren räumliche Ausdehnung im direkten Vergleich der Darstellung mittels MRT und DVT. Ergebnisse: Bei der Beschreibung der apikalen Läsionen war die Darsellung mittels DVT technikbedingt beschränkt auf die Zähne und rein knöcherne Befunde. Mittels der MRT konnte zusätzlich eine Darstellung des Weichteilgewebes erreicht werden. Die Darstellung im MRT erlaubte eine zufriedenstellende radiologische Diagnostik. Zusäzlich konnten Unterschiede im Aufbau der Mukosa und auch von soliden Einschlüssen differenziert werden. Alle mittels DVT identifzierten periapikalen Läsionen, wurden auch mittels MRT diagnostiziert. Die Daten vom MRT und DVT zeigten eine gute Korrelationen, wobei die Ausdehnung der Läsionen in der MRT Darstellung leicht, aber statistisch signifikant vergrößert resultierte. Bei mehreren Patienten wurden in der T2w Darstellung heterogene Läsionen gefunden und bei vier Patienten zeigte sich ein scharf begrenztes hyperintenses Signal in der Nähe des apikalen Foramens. Schlussfolgerung: Die Beurteilung des Weichgewebes und eventueller Einschlüsse mittels MRI können helfen die radiologische Diagnose einer apikalen Aufhellung weiter zu differenzieren. Die Studie indiziert den sinnvollen Einsatz der multi-kontrast MRT für die Identifizierung apikaler Osteolysen. Kernaussagen: • Die MRT erlaubt die Erkennung periapikaler Läsionen ohne Strahlenexposition. • Der Mehrwert der MRT erscheint in der Möglichkeit präoperative apikale Osteolysen zu charakterisieren. • Die MRT hat das Potential die Läsionsdimensionen genauer zu identifizieren.
This study compares the effective dose for different fields of view (FOVs), resolutions and X-ray parameters from two cone beam CT units: the KaVo 3D (three-dimensional) eXam and the KaVo Pan eXam Plus 3D (KaVo Dental, Biberach, Germany). Measurements were made using thermoluminescent dosemeter chips in a radiation analog dosimetry head and neck phantom. The calculations of effective doses are based on the ICRP 60 and ICRP 103 recommendations of the International Commission on Radiological Protection. Effective doses from the 3D eXam ranged between 32.8 µSv and 169.8 µSv, and for the Pan eXam Plus effective doses ranged between 40.2 µSv and 183.7 µSv; these were measured using ICRP 103 weighting factors in each case. The increase in effective dose between ICRP 60 and ICRP 103 recommendations averaged 157% for all measurements. Effective doses can be reduced significantly with the choice of lower resolutions and mAs settings as well as smaller FOVs to avoid tissues sensitive to radiation being inside the direct beam. Larger FOVs do not necessarily lead to higher effective doses.
Background: Practitioner’s knowledge and parental perspectives on dental general anaesthesia (GA) have been surveyed separately in the past. But in daily routine both need to collaborate for the benefit of the child. The aim of this paper was to compare parental and practitioner’s acceptance of GA with special focus on identifying factors which influence their differences in decision making.Methods: Questionnaires were conducted among 142 participants in a specialized paediatric dental clinic in Germany from February 2020 to February 2021. 51 German practitioners from private practices and clinics participated. Data collection included: age, gender, experience with GA, fear of GA, risk evaluation and indications for GA.Results: There were no gender related differences in decision making. Emotional factors are present in parents of younger children. Parents are more likely to express fear and uncertainty regarding GA than dentists. Prior experience with GA significantly decreases fears in GA for parents. Both agree that extent of the treatment and low compliance are a suitable indication for GA. Dentists are more likely to accept GA due to a mental disability than parents. Parents were more likely to accept GA than dentists when multiple extractions were needed (regardless of compliance) or acute pain was present.Conclusions: A significant divergence in risk evaluation, acceptance and decision-making could be found in parents compared to dentists. Influencing factors are previous experience, younger age of the child, lack of knowledge and indication for GA.
12 November 2018 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Aim Assessment of the visualization of titanium and ceramic dental implants using various isotropic three-dimensional magnetic resonance imaging (MRI) methods. Materials and Methods 21 dental implants (7 ceramic, 14 titanium) were scanned in vitro with a spatially isotropically resolved three-dimensional gradient echo (FFE), a turbo spin echo (SE) and an ultra-short-echo time (UTE) imaging technique. The resulting absolute volumes of the implants were quantified and the relative error to the theoretical volume was calculated. Results Ceramic implants and their periphery could be displayed well in all cases. The observed mean relative error results were 5.4 ± 2.3 % (UTE) to 6.5 ± 4.3 % (FFE). No significant difference was observed between the investigated MRI methods. The transition between implant and surrounding agarose could be shown in all cases without artifacts. Titanium implants resulted in mean relative errors between 1314 ± 350 % (FFE) and 2157 ± 810 % (SE). Here, significant differences were observed between the FFE and the SE and between the UTE and the SE sequence. The periphery of the implants could not be displayed in any case. Conclusion Use of the MRI technique for the diagnosis of peri-implantitis, the assessment of anatomical structures and planning of dental implantation is currently very limited but could be used more frequently, provided there are no disturbing or imaging-disturbing materials in the region of interest. MRI technology is not suitable in case of titanium implants. When using ceramic implants, MRI technology is an option. Key points Citation Format