Byki Huntjens

Dr. Byki Huntjens


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ICIrene Ctori
Irene Ctori
BHByki Huntjens
Byki Huntjens
To investigate repeatability and reproducibility of thickness of eight individual retinal layers at axial and lateral foveal locations, as well as foveal width, measured from Spectralis spectral domain optical coherence tomography (SD-OCT) scans using newly available retinal layer segmentation software. High-resolution SD-OCT scans were acquired for 40 eyes of 40 young healthy volunteers. Two scans were obtained in a single visit for each participant. Using new Spectralis segmentation software, two investigators independently obtained thickness of each of eight individual retinal layers at 0°, 2° and 5° eccentricities nasal and temporal to foveal centre, as well as foveal width measurements. Bland-Altman Coefficient of Repeatability (CoR) was calculated for inter-investigator and inter-scan agreement of all retinal measurements. Spearman's ρ indicated correlation of manually located central retinal thickness (RT0) with automated minimum foveal thickness (MFT) measurements. In addition, we investigated nasal-temporal symmetry of individual retinal layer thickness within the foveal pit. Inter-scan CoR values ranged from 3.1μm for axial retinal nerve fibre layer thickness to 15.0μm for the ganglion cell layer at 5° eccentricity. Mean foveal width was 2550μm ± 322μm with a CoR of 13μm for inter-investigator and 40μm for inter-scan agreement. Correlation of RT0 and MFT was very good (ρ = 0.97, P < 0.0005). There were no significant differences in thickness of any individual retinal layers at 2° nasal compared to temporal to fovea (P > 0.05); however this symmetry could not be found at 5° eccentricity. We demonstrate excellent repeatability and reproducibility of each of eight individual retinal layer thickness measurements within the fovea as well as foveal width using Spectralis SD-OCT segmentation software in a young, healthy cohort. Thickness of all individual retinal layers were symmetrical at 2°, but not at 5° eccentricity away from the fovea.

24 January 2022 in Ophthalmic and Physiological Optics
Verified
Journal Article
Open access
PDF file
RDRohit Dhakal
Rohit Dhakal
RSRakhee Shah
Rakhee Shah
BHByki Huntjens
Byki Huntjens
PVPavan K Verkicharla
Pavan K Verkicharla
JLJohn Lawrenson
John Lawrenson
Purpose: Outdoor light exposure is considered a safe and effective strategy to reduce myopia development and aligns with existing public health initiatives to promote healthier lifestyles in children. However, it is unclear whether this strategy reduces myopia progression in eyes that are already myopic. This study aims to conduct an overview of systematic reviews (SRs) reporting time spent outdoors as a strategy to prevent myopia or slow its progression in children. Methods: We searched the Cochrane Library, EMBASE, MEDLINE and CINAHL from inception to 1 November 2020 to identify SRs that evaluated the association between outdoor light exposure and myopia development or progression in children. Outcomes included incident myopia, prevalent myopia and change in spherical equivalent refraction (SER) and axial length (AL) to evaluate annual rates of myopia progression. The methodological quality and risk of bias of included SRs were assessed using the AMSTAR‐2 and ROBIS tools, respectively. Results: Seven SRs were identified, which included data from 47 primary studies with 63,920 participants. Pooled estimates (risk or odds ratios) consistently demonstrated that time outdoors was associated with a reduction in prevalence and incidence of myopia. In terms of slowing progression in eyes that were already myopic, the reported annual reductions in SER and AL from baseline were small (0.13–0.17 D) and regarded as clinically insignificant. Methodological quality assessment using AMSTAR‐2 found that all reviews had one or more critical flaws and the ROBIS tool identified a low risk of bias in only two of the included SRs. Conclusion: This overview found that increased exposure to outdoor light reduces myopia development. However, based on annual change in SER and AL, there is insufficient evidence for a clinically significant effect on myopia progression. The poor methodological quality and inconsistent reporting of the included systematic reviews reduce confidence in the estimates of effect.

10 January 2015 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
ICIrene Ctori
Irene Ctori
SGStephen Gruppetta
Stephen Gruppetta
BHByki Huntjens
Byki Huntjens

25 July 2018 in Documenta Ophthalmologica
Verified
Journal Article
Open access
PDF file
AHAngharad E. Hobby
Angharad E. Hobby
DKDiana Kozareva
Diana Kozareva
EYEkaterina Yonova-Doing
Ekaterina Yonova-Doing
IHIbtesham T. Hossain
Ibtesham T. Hossain
MKMohamed Katta
Mohamed Katta
OMOmar A. Mahroo
Omar A. Mahroo
Purpose A handheld device (the RETeval system, LKC Technologies) aims to increase the ease of electroretinogram (ERG) recording by using specially designed skin electrodes, rather than corneal electrodes. We explored effects of electrode position on response parameters recorded using this device. Methods Healthy adult twins were recruited from the TwinsUK cohort and underwent recording of light-adapted flicker ERGs (corresponding to international standard stimuli). In Group 1, skin electrodes were placed in a “comfortable” position, which was up to 20 mm below the lid margin. For subsequent participants (Group 2), the electrode was positioned 2 mm from the lid margin as recommended by the manufacturer. Amplitudes and peak times (averaged from both eyes) were compared between groups after age-matching and inclusion of only one twin per pair. Light-adapted flicker and flash ERGs were recorded for an additional 10 healthy subjects in two consecutive recording sessions: in the test eye, electrode position was varied from 2 to 10–20 mm below the lid margin between sessions; in the fellow (control) eye, the electrode was 2 mm below the lid margin throughout. Amplitudes and peak times (test eye normalised to control eye) were compared for the two sessions. Results Including one twin per pair, and age-matching yielded 28 individuals per group. Flicker ERG amplitudes were significantly lower for Group 1 than Group 2 participants (p = 0.0024). However, mean peak times did not differ between groups (p = 0.54). For the subjects in whom electrode position was changed between recording sessions, flash and flicker amplitudes were significantly lower when positioned further from the lid margin (p < 0.005), but peak times were similar (p > 0.5). Conclusions Moving the skin electrodes further from the lid margin significantly reduces response amplitudes, highlighting the importance of consistent electrode positioning. However, this does not significantly affect peak times. Thus, it may be feasible to adopt a more comfortable position in participants who cannot tolerate the recommended position if analysis is restricted to peak time parameters.

1 April 2020 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
BHByki Huntjens
Byki Huntjens
MBMandeep Basi
Mandeep Basi
MNManbir Nagra
Manbir Nagra

1 April 2021 in Journal of Optometry
Verified
Journal Article
Open access
BHBrooke Hutchins
Brooke Hutchins
BHByki Huntjens
Byki Huntjens
Presbyopia is the gradual inability to focus near objects with age. This study explores patients' attitudes and beliefs towards presbyopia including preferred modes of near refractive correction. In the United Kingdom, twenty-four volunteers completed an online questionnaire and attended a structured, recorded focus group. Participants' age ranged between 36 and 48 years, representing a pre-presbyopic and a presbyopic population. Attitudes and beliefs about presbyopia, its significance, and opinions about current refractive correction including multifocal contact lenses were transcribed and coded using content analysis for overarching themes and patterns. Six participants (25%) were already wearing a near visual correction while 18 (75%) were not. Five key primary themes with clear inter-participant similarities were identified as 'age-related' (75%), 'acceptance' (50%), clear lack of 'familiarity with the word presbyopia' (65%), a mixed/ reluctant attitude 'towards (multifocal) contact lenses' (62.5%), and 'comfort and convenience' of a presbyopic correction (79%) whereby cost is of less importance. The need for a reading correction was perceived as a sign of age. Spectacles were the most preferred mode of near vision correction, while comfort and convenience were seen as more important than cost. Patient education about presbyopia is lacking. Multifocal contact lenses are not necessarily the preferred visual correction even if the patient already wears contact lenses for distance.