Purpose The signal‐to‐noise ratio and resolution are two competing parameters for dental MRI and are highly dependent on the radiofrequency coil configuration and performance. The purpose of this work is to describe an intraoral approach for imaging teeth with the radiofrequency coil plane oriented orthogonally to the Zeeman field to use the transverse components of the B1 field for transmitting and receiving the NMR signal. Methods A single loop coil with shape and size fitted to the average adult maxillary arch was built and tested with a phantom and human subjects in vivo on a whole‐body 4 T MRI scanner. Supporting Biot‐Savart law simulations were performed with Matlab. Results In the occlusal position (in bite plane between the upper and lower teeth), the sensitive volume of the coil encompasses the most important dental structures, the teeth and their supporting structures, while uninteresting tissues containing much higher proton density (cheeks, lips, and tongue) are outside the sensitive volume. The presented images and simulated data show the advantages of using a coil in the orthogonal orientation for dental applications. Conclusion The transverse components of the B1 field of a surface coil can effectively be used for imaging of teeth and associated structures. Magn Reson Med 72:160–165, 2014.
Recently introduced 3D radial MRI pulse sequence entitled Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) having virtually zero acquisition delay was used to obtain functional MRI (fMRI) contrast in rat's brain at 9.4 T during deep brain stimulation (DBS). The results demonstrate that MB-SWIFT allows functional images free of susceptibility artifacts, and provides an excellent fMRI activation contrast in the brain. Flip angle dependence of the MB-SWIFT fMRI signal and elimination of the fMRI contrast while using saturation bands, indicate a blood flow origin of the observed fMRI contrast. MB-SWIFT fMRI modality permits activation studies in the close proximity to an implanted lead, which is not possible to achieve with conventionally used gradient echo and spin echo - echo planar imaging fMRI techniques. We conclude that MB-SWIFT fMRI is a powerful imaging modality for investigations of functional responses during DBS.
Objectives:To evaluate the limit of tooth crack width visualization by two magnetic resonance imaging (MRI) pulse sequences in comparison with cone-beam CT (CBCT).Methods:Two extracted human teeth with known crack locations and dimensions, as determined by reference standard microCT, were selected for experimental imaging. Crack location/dimension and the presence of common dental restorative materials such as amalgam were typical of that found clinically. Experimental imaging consisted of conventional CBCT scans and MRI scans with two pulse sequences including SWIFT (Sweep Imaging with Fourier Transformation) and GRE (Gradient Echo). CBCT and MRI images of extracted teeth were acquired using acquisition parameters identical to those used for in vivo imaging. Experimental and reference standard images were registered and the limit of tooth crack visualization was determined.Results:Collected images indicate that SWIFT could demonstrate cracks with 20 µm width, which was 10 times narrower than the imaging ...
16 July 2021 in IEEE Transactions on Biomedical Engineering
Objective: In dental MRI, intraoral coils provide higher signal-to-noise ratio (SNR) than coils placed outside the mouth. This study aims to design an intraoral dipole antenna and demonstrates the feasibility of combining it with an extraoral coil. Methods: Dipole antenna design was chosen over loop design, as it is open toward the distal; therefore, it does not restrain tongue movement. The dipole design offers also an increased depth-of-sensitivity that allows for MRI of dental roots. Different dipole antenna designs were simulated using a finite-difference-time-domain approach. Ribbon, wire, and multi-wire arms were compared. The best design was improved further by covering the ends of the dipole arms with a high-permittivity material. Phantom and in vivo measurements were conducted on a 3T clinical MRI system. Results: The best transmit efficiency and homogeneity was achieved with a multi-wire curved dipole antenna with 7 wires for each arm. With an additional high-permittivity cap the transmit field inhomogeneity was further reduced from 20% to 5% along the dipole arm. When combined with extraoral flexible surface-coil, the coupling between the coils was less than -32dB and SNR was increased. Conclusion: Using intraoral dipole design instead of loop improves patient comfort. We demonstrated feasibility of the intraoral dipole combined with an extraoral flexible coil-array for dental MRI. Dipole antenna enabled decreasing imaging field-of-view, and reduced the prevalent signal from tongue. Significance: This study highlights the advantages and the main challenges of the intraoral RF coils and describes a novel RF coil that addresses those challenges.