Süleyman Filiz

Dr. Süleyman Filiz

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2024 in Diagnostic and Interventional Radiology
Verified
Journal Article
Open access
SFSüleyman Filiz
Süleyman Filiz
SGSafiye Gürel
Safiye Gürel
KGKamil Gürel
Kamil Gürel
Our study aimed to obtain clinical indication-based typical dose values and size-specific dose estimates (SSDEs) for multiphasic abdominopelvic computed tomography (CT) examinations and to review our data with published diagnostic reference levels (DRLs). In this retrospective study, multiphasic liver, kidney, pancreas, and mesenteric ischemia protocol CT scans performed at our center between January 2018 and December 2021 were analyzed. The clinical indications were hepatocellular carcinoma, renal cell carcinoma, pancreas adenocarcinoma, and mesenteric ischemia. The computed tomography dose index volume (CTDIvol) and dose-length product (DLP) values were recorded, and the SSDE and effective dose (ED) values were calculated. The water-equivalent diameter (Dw) value required for the SSDE calculation was measured using the automated calculation of the Dw program. The total number of patients was 514, with 86 patients excluded from this study. The dose values were calculated for 426 patients (183 female and 243 male; 111 liver, 120 kidney, 85 pancreas, and 110 mesenteric). The median values for the CTDIvol, DLP, SSDE, and ED were 6.86 mGy, 683.02 mGy. cm, 8.75 mGy, and 10.45 mSv for the liver CT; 8.37 mGy, 908.37 mGy.cm, 10.37 mGy, and 13.89 mSv for the kidney CT; 7.82 mGy, 517.98 mGy.cm, 10.01 mGy, and 7.92 mSv for the pancreas CT; and 9.48 mGy, 983.68 mGy.cm, 12.78 mGy, and 13.86 mSv for the mesenteric CT, respectively. All dose values were lower than the published DRLs. The literature reveals large differences in the multiphasic abdominopelvic CT protocols, especially in the number of phases and scan length. This situation makes comparing dose values difficult. Dose studies revealing the protocol parameters in detail are needed so that institutions can compare and optimize their own protocols. Additionally, users should periodically check the dose values in their own institutions.

29 May 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
HAKAN BAŞHAKAN BAŞ
HAKAN BAŞ
SFSüleyman Filiz
Süleyman Filiz
Background/Objectives: This study aims to assess ovarian stromal vascularity using microvascular imaging in reproductive-aged women with polycystic ovarian morphology (PCOM) and to explore its associations with endocrine parameters and polycystic ovary syndrome (PCOS) phenotypes. Methods: We conducted a retrospective, single-center study between January 2021 and November 2023. Women aged 18–49 who met the PCOM criteria (≥20 follicles measuring 2–9 mm or an ovarian volume >10 cm3 in at least one ovary) were included. Pelvic ultrasound with MV-Flow Doppler imaging was used to quantify the stromal vascularity index (VI). On the same day, serum levels of FSH, LH, total and free testosterone, DHEAS, and estradiol were measured. PCOS phenotypes (A, C, D, and non-PCOS) were classified according to the Rotterdam criteria. Statistical analysis involved interobserver agreement using intraclass correlation coefficients (ICCs), correlation analysis for hormonal associations, and group comparisons using ANOVA. Results: A total of 111 women (mean age: 27.4 ± 6.1 years) were evaluated. The mean VI was 43.88 ± 19.84, with good interobserver agreement (ICC = 0.79; 95% CI: 0.65–0.88). VI was highest in Phenotype A (61.36 ± 10.11), followed by Phenotype C (42.57 ± 3.59), Phenotype D (26.47 ± 4.24), and Non-PCOS individuals (9.95 ± 5.44; p < 0.001). VI showed strong positive correlations with total testosterone (r = 0.797) and free testosterone (r = 0.778), and a moderate negative correlation with DHEAS (r = −0.483; p < 0.001). Conclusions: Microvascular imaging is a promising tool for quantifying ovarian stromal vascularity in PCOM. Its strong correlation with androgen levels, especially in hyperandrogenic phenotypes, highlights its potential role in enhancing diagnostic precision and deepening our understanding of PCOS pathophysiology.

18 November 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
HAKAN BAŞHAKAN BAŞ
HAKAN BAŞ
SFSüleyman Filiz
Süleyman Filiz
Background/Objectives: We aimed to characterize the microvascular imaging (MI) to demonstrate in hepatic hemangiomas in routine practice and to quantify the impact of lesion depth on MI signal detectability, and—when present—describe the distribution of MI appearances. Methods: In this single-center, retrospective study from January 2021 to December 2023, we screened 91 patients with 121 focal hepatic lesions on ultrasound. Lesions without typical hemangioma enhancement on dynamic MRI or dynamic CT were excluded. Two radiologists independently assessed MI signals and patterns using the Jeon classification, blinded to clinical and CT/MRI data; inter-observer agreement was quantified with Cohen’s κ. Results: Of 121 screened lesions, 36 lacked typical enhancement and were excluded; 85 hemangiomas remained. A total of 13 were excluded for motion artifacts near the heart or pulsatile vessels, yielding 72 hemangiomas (61 patients) for analysis. No lesion showed flow on color or power Doppler. MI signals were detected in 68/72 hemangiomas (94.4%). Among signal-positive lesions (n = 68), the patterns were non-specific in 25.0% (17/68), nodular rim in 22.1% (15/68), strip rim in 17.6% (12/68), central dot-like in 16.2% (11/68), peripheral dot-like in 10.3% (7/68), and staining in 8.8% (6/68). Signal-negative lesions were deeper than signal-positive lesions (median depth: 85 mm vs. 41.5 mm; p < 0.05). The inter-observer agreement was very good (κ = 0.821, 95% CI 0.767–0.921). Conclusions: MI is a reproducible, contrast-free technique that demonstrates hemangioma vascularity with high detection rates, particularly in more superficial lesions. In this cohort, lesion depth rather than size was the primary determinant of MI signal detectability. MI should be considered complementary to CT/MRI and may be especially useful where contrast agents are unavailable or contraindicated.

1 October 2024 in Journal of the Anatomical Society of India
Verified
Journal Article
Open access
ZCZeliha Coşgun
Zeliha Coşgun
SFSüleyman Filiz
Süleyman Filiz
Myxoma is the most common type of primary benign heart tumor and is usually easily identified by echocardiography. Tumor vascularity is a rare finding in atrial myxomas and reported cases of the right atrial myxomas most frequently involve feeding vessels from the right coronary artery or, less frequently, from both coronary arteries. In this case report, an echocardiographic examination of a 74-year-old male, who was admitted to hospital with chest pain revealed an echogenic solid mass in the right atrium. A coronary angiography showed an arteriocavity fistula connecting the feeding artery to the cardiac chamber. In the computed tomography angiography examination performed, a mass was observed with intense vascularity, containing feeding vessels from the left circumflex artery, the right inferior phrenic artery, and the left hepatic artery; calcifications in the right atrium were also present. The mass was completely and successfully resected. Pathology results of the mass were compatible with cardiac myxoma. This was an atypical case of a right atrial myxoma due to the presence of intense vascularization and the feed from the cardiac and extracardiac arteries.

28 February 2025 in Türk Radyoloji Seminerleri
Verified
Journal Article
Open access
SFSüleyman Filiz
Süleyman Filiz
SGSafiye Gürel
Safiye Gürel
What Are Diagnostic Reference Levels? How Are They Established? - Türk Radyoloji Seminerleri

10 February 2026 in NeuroToxicology
Verified
Journal Article
Closed access
TATuğba Akkale
Tuğba Akkale
NŞNuriye Kayalı Şendur
Nuriye Kayalı Şendur
SFSüleyman Filiz
Süleyman Filiz
NÇNilüfer Merve Çelik
Nilüfer Merve Çelik