Andrea Poggetti

Dr. Andrea Poggetti

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2017 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
MGMartina Giannaccini
Martina Giannaccini
MCM. Pilar Calatayud
M. Pilar Calatayud
APAndrea Poggetti
Andrea Poggetti
SCSilvia Corbianco
Silvia Corbianco
MNMichela Novelli
Michela Novelli
RVRaffa Vittoria
Raffa Vittoria

7 April 2016 in Journal of Hand Surgery (European Volume)
Verified
Journal Article
Closed access
TGThomas Giesen
Thomas Giesen
RGR. Gazzola
R. Gazzola
APAndrea Poggetti
Andrea Poggetti
PGP. Giovanoli
P. Giovanoli
MCMaurizio Calcagni
Maurizio Calcagni
We present the results of 26 patients with 31 consecutive displaced or unstable extra-articular fractures of the base and shaft of the proximal and middle phalanges of the digits of the hand, treated over a period of 12 months with an intramedullary headless compression screw and early mobilization with no splinting. All fractures healed with no major complications. Only one patient, who had a pathological fracture through an enchondroma, required a tenolysis to improve the mobility of the finger. This technique seems to be technically simple, effective and with few drawbacks. Level of evidence: IV

7 April 2016 in Journal of Hand Surgery (European Volume)
Verified
Journal Article
Closed access
PDF file
PBP. Borbas
P. Borbas
MDM. Dreu
M. Dreu
APAndrea Poggetti
Andrea Poggetti
MCMaurizio Calcagni
Maurizio Calcagni
TGThomas Giesen
Thomas Giesen
MMM. Manuel
M. Manuel
The aim of this study was to quantify the articular cartilage defect created with two different antegrade techniques of intramedullary osteosynthesis with a headless compression screw inserted through the metacarpophalangeal joint. In 12 out of 24 fingers from six cadaveric hands, a trans-articular technique with cannulated headless compression screws (2.2 and 3.0 mm diameter) was used; whereas in the other 12 fingers, an intra-articular fixation technique was used. The areas of the articular surface and the defects created were measured with a digital image software program. All measurements were made twice by two observers. In the intra-articular technique, the average defect in the base of the articular surface of the proximal phalanx was 4.6% with the 2.2 mm headless compression screw and 8.5% with the 3.0 mm screw. In the trans-articular technique, the defect size was slightly smaller; 4.2% with the 2.2 mm screw and 8% with the 3.0 mm screw, but the differences were not statistically significant. The main advantage of the intra-articular technique was that it avoided damage to the articular surface of the metacarpal head.

19 February 2010 in MUSCULOSKELETAL SURGERY
Verified
Journal Article
Closed access
PDF file
MRMarco Rosati
Marco Rosati
PPPaolo Domenico Parchi
Paolo Domenico Parchi
MCMatilde Cacianti
Matilde Cacianti
APAndrea Poggetti
Andrea Poggetti
MLMichele Lisanti
Michele Lisanti

22 August 2016 in Frontiers in Aging Neuroscience
Verified
Journal Article
Open access
PDF file
PPPaolo Domenico Parchi
Paolo Domenico Parchi
Orazio VittorioOrazio Vittorio
Orazio Vittorio
LALorenzo Andreani
Lorenzo Andreani
PBPietro Battistini
Pietro Battistini
NPNicola Piolanti
Nicola Piolanti
MLMichele Lisanti
Michele Lisanti
Tendon injuries are commonly met in the emergency department. Unfortunately, tendon tissue has limited regeneration potential and usually the consequent formation of scar tissue causes inferior mechanical properties Nanoparticles could be used in different way to improve tendon healing and regeneration, ranging from scaffolds manufacturing (increasing the strength and endurance or anti-adhesions, anti-microbial and anti-inflammatory properties) to gene therapy. This paper aims to summarize the most relevant studies showing the potential application of nanoparticles for tendon tissue regeneration

20 March 2018 in Journal of Hand and Microsurgery
Verified
Journal Article
Closed access
PDF file
APAndrea Poggetti
Andrea Poggetti
ANAnna Maria Nucci
Anna Maria Nucci
TGThomas Giesen
Thomas Giesen
MCMaurizio Calcagni
Maurizio Calcagni
SMStefano Marchetti
Stefano Marchetti
MLMichele Lisanti
Michele Lisanti
Metacarpal fractures constitute 7.8% of the upper extremity fractures. The common treatments remain nonsurgical procedure, but high-demanding patients or unstable fractures require fixation with Kirschner wire (K-wires), plate, and screws. However, these approaches may cause scarring and adhesion with poor functional results. From 2014 to 2015, the authors used an intramedullary headless screw to treat 25 patients (24 men, 1 woman) with metacarpal bones fractures (20 V, 3 IV, 1 III, and 1 II). The fractures patterns were 23 fractures of distal third of metacarpal bone (16 oblique, 5 comminute configurations, and 2 transverse), 1 fracture of the base of the II metacarpal bone. One case presented a multiple metacarpal and phalangeal facture associated. The authors used wide-awake anesthesia (bupivacaine-epinephrine 1:100,000) and intramedullary titanium headless screw fixation percutaneously inserted (CCS Medartis and HCS Synthes 3 mm of diameter). No open reduction was needed. Early active mobilization started with a buddy strapping soon after surgery (0–3 days). The authors followed all patients until satisfactory function was achieved (4–6 weeks) and recorded the time till return to work. All fracture healed with less than 5 degrees of rotational or axial deformities. All patients return to work within 2.38 weeks after surgery (0.5–6 weeks). No cases of complex regional pain syndrome (CRPS), tendon lesions, nerve injuries, infection, hardware protruding, or mobilization were reported. Intramedullary screw fixation with wide-awake anesthesia for transverse, oblique, and select comminuted fractures treatment metacarpal fractures represent a reliable option to early active mobilization recovery and a quick return to the work and ordinary activities.