Jørgen Arendt Jensen

Dr. Jørgen Arendt Jensen

orcid

Research Focus & Metrics

Academic Career Length

43Years (1984-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 1992 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
NSN.B. Svendsen
N.B. Svendsen
A method for simulation of pulsed pressure fields from arbitrarily shaped, apodized and excited ultrasound transducers is suggested. It relies on the Tupholme-Stepanishen method for calculating pulsed pressure fields, and can also handle the continuous wave and pulse-echo case. The field is calculated by dividing the surface into small rectangles and then Summing their response. A fast calculation is obtained by using the far-field approximation. Examples of the accuracy of the approach and actual calculation times are given.<>

1 December 2006 in Ultrasonics
Verified
Journal Article
Closed access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
SNSvetoslav Ivanov Nikolov
Svetoslav Ivanov Nikolov
KGKim Løkke Gammelmark
Kim Løkke Gammelmark
MPMorten Høgholm Pedersen
Morten Høgholm Pedersen

1 May 1998 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
PMP. Munk
P. Munk
The paper describes a new method for determining the velocity vector of a remotely sensed object using either sound or electromagnetic radiation. The movement of the object is determined from a field with spatial oscillations in both the axial direction of the transducer and in one or two directions transverse to the axial direction. By using a number of pulse emissions, the inter-pulse movement can be estimated and the velocity found from the estimated movement and the time between pulses. The method is based on the principle of using transverse spatial modulation for making the received signal influenced by transverse motion. Such a transverse modulation can be generated by using apodization on individual transducer array elements together with a special focusing scheme. A method for making such a field is presented along with a suitable two-dimensional velocity estimator. An implementation usable in medical ultrasound is described, and simulated results are presented. Simulation results for a flow of 1 m/s in a tube rotated in the image plane at specific angles (0, 15, 35, 55, 75, and 90 degrees) are made and characterized by the estimated mean value, estimated angle, and the standard deviation in the lateral and longitudinal direction. The average performance of the estimates for all angles is: mean velocity 0.99 m/s, longitudinal S.D. 0.015 m/s, and lateral S.D. 0.196 m/s. For flow parallel to the transducer the results are: mean velocity 0.95 m/s, angle 0.10, longitudinal S.D. 0.020 m/s, and lateral S.D. 0.172 m/s.

21 March 2005 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
TMT. Misaridis
T. Misaridis
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
This paper, the first from a series of three papers on the application of coded excitation signals in medical ultrasound, discusses the basic principles and ultrasound-related problems of pulse compression. The concepts of signal modulation and matched filtering are given, and a simple model of attenuation relates the matched filter response with the ambiguity function, known from radar. Based on this analysis and the properties of the ambiguity function, the selection of coded waveforms suitable for ultrasound imaging is discussed. It is shown that linear frequency modulation (FM) signals have the best and most robust features for ultrasound imaging. Other coded signals such as nonlinear FM and binary complementary Golay codes also have been considered and characterized in terms of signal-to-noise ratio (SNR) and sensitivity to frequency shifts. Using the simulation program Field II, it is found that in the case of linear FM signals, a SNR improvement of 12 to 18 dB can be expected for large imaging depths in attenuating media, without any depth-dependent filter compensation. In contrast, nonlinear FM modulation and binary codes are shown to give a SNR improvement of only 4 to 9 dB when processed with a matched filter. Other issues, such as depth-dependent matched filtering and use of filters other than the matched filter (inverse and Wiener filters) also are addressed.

1 January 1991 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
An inhomogeneous wave equation is derived describing propagation and scattering of ultrasound in an inhomogeneous medium. The scattering term is a function of density and propagation velocity perturbations. The integral solution to the wave equation is combined with a general description of the field from typical transducers used in clinical ultrasound to yield a model for the received pulse-echo pressure field. Analytic expressions are found in the literature for a number of transducers, and any transducer excitation can be incorporated into the model. An example is given for a concave, nonapodized transducer in which the predicted pressure field is compared to a measured field.

8 August 2008 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JUJesper Udesen
Jesper Udesen
FGFredrik Gran
Fredrik Gran
KHKristoffer Lindskov Hansen
Kristoffer Lindskov Hansen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
CTCarsten Thomsen
Carsten Thomsen
Michael Bachmann NielsenMichael Bachmann Nielsen
Michael Bachmann Nielsen
Conventional ultrasound methods for acquiring color images of blood velocity are limited by a relatively low frame-rate and are restricted to give velocity estimates along the ultrasound beam direction only. To circumvent these limitations, the method presented in this paper uses 3 techniques: 1) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13 -bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer. An improved parameter set for the method was identified from the parameter study, and a flow rig measurement was performed using the same improved setup as in the simulations. Finally, the common carotid artery of a healthy male was scanned with a scan sequence that satisfies the limits set by the Food and Drug Administration. Vector velocity images were obtained with a frame-rate of 100 Hz where 40 speckle images are used for each vector velocity image. It was found that the blood flow approximately followed the vessel wall, and that maximum velocity was approximately 1 m/s, which is a normal value for a healthy person. To further evaluate the method, the test person was scanned with magnetic resonance (MR) angiography. The volume flow derived from the MR scanning was compared with that from the ultrasound scanning. A deviation of 9% between the 2 volume flow estimates was found.