Prabhat Baniya

Dr. Prabhat Baniya

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2018 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Open access
PBPrabhat Baniya
Prabhat Baniya
ABAimeric Bisognin
Aimeric Bisognin
KMKathleen L. Melde
Kathleen L. Melde
CLCyril Luxey
Cyril Luxey
A 60-GHz switched beam chip-to-chip antenna array is introduced. The array consists of four center fed circular patch elements with side vias in a 2 × 2 grid arrangement forming a planar array. The array is designed to fit on a typical multicore chip for reconfigurable interchip wireless communication. The array main beam is switched by changing the inter-element phase shifts in the azimuth plane. The switching of the main beam is analyzed and verified through full wave simulation. The design presented is an improvement over a previous design of a two-element antenna array. The Friis transmission equation with polarization components taken into account is used to model the interchip wireless link. To verify the model, a transmission coefficient measurement is made between a pair of the two-element arrays separated by a 10 mm distance. Both simulated and measured radiation patterns of the twoelement array are presented for use in the Friis equation to calculate the transmission coefficients. Full wave simulation of the array pair is also performed. The calculated results obtained from the Friis model agree well with both the measured and full wave simulated results. The Friis model is used to calculate both signal and interference levels.

16 December 2018 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
PBPrabhat Baniya
Prabhat Baniya
KMKathleen L. Melde
Kathleen L. Melde
A two-dimensional Butler matrix feed network is designed, implemented, and integrated with a 60 GHz 2 × 2 circular patch planar array for chip-to-chip communications. The realized antenna module is a thin multilayer microstrip structure with a footprint small enough to fit over a typical multicore chip. The network enables endfire (azimuthal) scan of the array main beam in the four diagonal directions, which is demonstrated for the first time in this letter. The antenna module provides a seamless and practical way to achieve reconfigurable interchip communication in multicore multichip (MCMC) systems. A hybrid space-surface wave interconnect is proposed that takes advantage of surface-wave coupling. The matrix is a four-input, four-output, i.e., 4 × 4, network consisting of four interconnected quadrature (90°) hybrid couplers. A multiantenna module (MAM) consisting of five antenna modules that emulates diagonal interchip communication in MCMC systems is fabricated. The simulation and measurement of transmission coefficients between the antenna modules on the MAM are performed and compared.

7 September 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PBPrabhat Baniya
Prabhat Baniya
MTMaryam Tebyani
Maryam Tebyani
NANarges Asefifeyzabadi
Narges Asefifeyzabadi
TNTiffany Nguyen
Tiffany Nguyen
CHCristian Hernandez
Cristian Hernandez
MTMircea Teodorescu
Mircea Teodorescu
The development of wearable bioelectronic systems is a promising approach for optimal delivery of therapeutic treatments. These systems can provide continuous delivery of ions, charged biomolecules, and an electric field for various medical applications. However, rapid prototyping of wearable bioelectronic systems for controlled delivery of specific treatments with a scalable fabrication process is challenging. We present a wearable bioelectronic system comprised of a polydimethylsiloxane (PDMS) device cast in customizable 3D printed molds and a printed circuit board (PCB), which employs commercially available engineering components and tools throughout design and fabrication. The system, featuring solution-filled reservoirs, embedded electrodes, and hydrogel-filled capillary tubing, is assembled modularly. The PDMS and PCB both contain matching through-holes designed to hold metallic contact posts coated with silver epoxy, allowing for mechanical and electrical integration. This assembly scheme allows us to interchange subsystem components, such as various PCB designs and reservoir solutions. We present three PCB designs: a wired version and two battery-powered versions with and without onboard memory. The wired design uses an external voltage controller for device actuation. The battery-powered PCB design uses a microcontroller unit to enable pre-programmed applied voltages and deep sleep mode to prolong battery run time. Finally, the battery-powered PCB with onboard memory is developed to record delivered currents, which enables us to verify treatment dose delivered. To demonstrate the functionality of the platform, the devices are used to deliver H $$^+$$ + in vivo using mouse models and fluoxetine ex vivo using a simulated wound environment. Immunohistochemistry staining shows an improvement of 35.86% in the M1/M2 ratio of H $$^+$$ + —treated wounds compared with control wounds, indicating the potential of the platform to improve wound healing.

1 December 2022 in AIP Advances
Verified
Journal Article
Open access
PDF file
HDHarika Dechiraju
Harika Dechiraju
JSJohn Selberg
John Selberg
MJManping Jia
Manping Jia
PPPattawong Pansodtee
Pattawong Pansodtee
Houpu LiHoupu Li
Houpu Li
MRMarco Rolandi
Marco Rolandi
Bioelectronic devices that interface electronics with biological systems can actuate and control biological processes. The potassium ion plays a vital role in cell membrane physiology, maintaining the cell membrane potential (Vmem) and generating action potentials. In this work, we present two bioelectronic ion pumps that use an electronic signal to modulate the potassium ion concentration in solution. The first ion pump is designed to integrate directly with six-well cell culture plates for optimal ease of integration with in vitro cell culture, and the second on-chip ion pump provides high spatial resolution. These pumps offer increased ease of integration with in vitro systems and demonstrate K+ concentration distribution with high spatial resolution. We systematically investigate the ion pump’s performance using electrical characterization and computational modeling, and we explore closed-loop control of K+ concentration using fluorescent dyes as indicators. As a proof-of-concept, we study the effects of modulating K+ concentration on Vmem of THP-1 macrophages.

11 July 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
FLFan Lu
Fan Lu
KZKsenia Zlobina
Ksenia Zlobina
PBPrabhat Baniya
Prabhat Baniya
Houpu LiHoupu Li
Houpu Li
NRNicholas Rondoni
Nicholas Rondoni
MGMarcella Gomez
Marcella Gomez
Advancements in bioelectronic sensors and actuators have paved the way for real-time monitoring and control of the progression of wound healing. Real-time monitoring allows for precise adjustment of treatment strategies to align them with an individual’s unique biological response. However, due to the complexities of human–drug interactions and a lack of predictive models, it is challenging to determine how one should adjust drug dosage to achieve the desired biological response. This work proposes an adaptive closed-loop control framework that integrates deep learning, optimal control, and reinforcement learning to update treatment strategies in real time, with the goal of accelerating wound closure. The proposed approach eliminates the need for mathematical modeling of complex nonlinear wound-healing dynamics. We demonstrate the convergence of the controller via an in silico experimental setup, where the proposed approach successfully accelerated the wound-healing process by 17.71%. Finally, we share the experimental setup and results of an in vivo implementation to highlight the translational potential of our work. Our data-driven model suggests that the treatment strategy, as determined by our deep reinforcement learning algorithm, results in an accelerated onset of inflammation and subsequent transition to proliferation in a porcine wound model.

14 July 2021 in IEEE Access
Verified
Journal Article
Open access
PBPrabhat Baniya
Prabhat Baniya
KMKathleen L. Melde
Kathleen L. Melde
Traditional wired interconnects in multicore multichip (MCMC) systems can be replaced with chip-integrated switched beam antenna arrays to provide reconfigurable chip-to-chip communications. By simply switching the directive beams of the arrays, the chips can be made to dynamically communicate with their surrounding neighbors. Radiation from the arrays in the unintended direction, however, causes interference when multiple pairs of chips are simultaneously communicating. In this paper, the noise and interference limitations of such concurrent chip-to-chip communication systems are analyzed at 60 GHz for the channels defined in the IEEE 802.11ay standard. Each array consists of eight substrate integrated waveguide (SIW) horn elements printed on a thin dielectric substrate. The elements can be individually excited to produce eight directive endfire beams, providing full 360° coverage, in the horizontal plane. The substrate acts as a hybrid space-surface wave interconnect (HSSW-I) that allows near-field, space and surface wave coupling to occur between the arrays, and thus, increases interchip transmission. The antenna and link parameters that dictate the signal-to-noise-plus-interference ratio (SNIR) of such systems are established by considering all the major components. The maximum achievable data rates are then determined based on the SNIR, calculated from the measured and simulated transmission coefficients between the arrays.