Recent advances in biointerfaces have led to the development of wearable devices that can provide insights into personal health. As wearable modules, microneedles can extract analytes of interest from interstitial fluid in a minimally invasive fashion. However, some microneedles are limited by their ability to perform highly effective extraction and real-time monitoring for macromolecule biomarkers simultaneously. Here we show the synergetic effect of CRISPR-activated graphene biointerfaces, and report an on-line wearable microneedle patch for extraction and in vivo long-term monitoring of universal cell-free DNA. In this study, this wearable system enables real-time monitoring of Epstein-Barr virus, sepsis, and kidney transplantation cell-free DNA, with anti-interference ability of 60% fetal bovine serum, and has satisfactory stable sensitivity for 10 days in vivo. The experimental results of immunodeficient mouse models shows the feasibility and practicability of this proposed method. This wearable patch holds great promise for long-term in vivo monitoring of cell-free DNA and could potentially be used for early disease screening and prognosis.
Contamination of the environment by mercury(II) ions (Hg2+) poses a serious threat to human health and ecosystems. Up to now, many reported Hg2+ sensors require complex procedures, long measurement times and sophisticated instrumentation. We have developed a simple, rapid, low cost and naked-eye quantitative method for Hg2+ environmental analysis using a paper-based colorimetric device (PCD). The sample solution to which platinum nanoparticles (PtNPs) have been added is dispensed to the detection zone on the PCD, where the 3,3,5,5-tetramethylbenzidine (TMB) substrate has been pre-loaded. The PtNPs effect a rapid oxidization of TMB, inducing blue colorization on the PCD. However, Hg2+ in the solution rapidly interact with the PtNPs, suppressing the oxidation capacity and hence causing a decrease in blue intensity, which can be observed directly by the naked eye. Moreover, Hg2+ at concentrations as low as 0.01 uM, can be successfully monitored using a fiber optic device, which gives a digital readout proportional to the intensity of the blue color change. This paper-based colorimetric device (PCD) shows great potential for field measurement of Hg2+.
Food allergies can greatly harm people’s health, and therefore detecting allergens in foods is extremely important. By integrating loop-mediated isothermal amplification (LAMP) with a microfluidic chip, we have developed a method for detecting the allergen genes of peanut (Arachis hypogaea), sesame (Sesamum indicum), and soybean (Glycine max) using a colorimetric method suitable for the naked eye, known as the colorimetric LAMP microfluidic chip. In the presence of peanut, sesame, or soybean in the samples, the corresponding reaction well of the microfluidic chip will appear pink, or otherwise remain light brown. This method of detection is specific and can easily distinguish these three allergens from others in foods. The detection limit for peanut, sesame and soybean allergens was 0.4 ng/μL using the LAMP-microfluidic chip. The accuracy of this novel and rapid method was validated using allergenic foods obtained commercially and was comparable with that of the typical TaqMan real-time PCR method.