The pathway to the maxillary sinus is anatomically curved and narrow. Thus, the conventional approach using a straight endoscope and surgical tools is difficult to diagnose and treat some blind regions of the maxillary sinus through the nostrils. Such cases are usually dealt with by an approach with an external incision that causes large invasive surgery. In order to approach the blind regions without any external incision, a new bendable device and an image-guided robotic approach for the maxillary sinus surgery are required. This work reports design, development, and validation of an image-guided dual master–slave robotic system for the maxillary sinus surgery. Initially, specifications of the robotic system for sinus surgery are decided by analysis of the anatomical structure of the sinus. A method for determining the design parameters of continuum type salve robot is also presented. Based on the specifications and the design parameter determining method, a compact design of bendable dual slave robotic system for inspection and biopsy operation of the maxillary sinus area is devised and workspace analysis for verifying the robot design is conducted. The performance of the dual master–slave system equipped with flexible devices is validated through several phantom tests. The results suggest that bendable end-effectors and navigation software are useful to navigate and treat blind regions inside general sinus areas as well as the maxillary sinus.
22 December 2016 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Current vascular intervention inevitably exposes a large amount of X-ray to both an operator and a patient during the procedure. The purpose of this study is to propose a new catheter driving system which assists the operator in aspects of less X-ray exposure and convenient user interface. For this, an assembly-type 4-degree-of-freedom master–slave system was designed and tested to verify the efficiency. First, current vascular intervention procedures are analyzed to develop a new robotic procedure that enables us to use conventional vascular intervention devices such as catheter and guidewire which are commercially available in the market. Some parts of the slave robot which contact the devices were designed to be easily assembled and dissembled from the main body of the slave robot for sterilization. A master robot is compactly designed to conduct insertion and rotational motion and is able to switch from the guidewire driving mode to the catheter driving mode or vice versa. A phantom resembling the human arteries was developed, and the master–slave robotic system is tested using the phantom. The contact force of the guidewire tip according to the shape of the arteries is measured and reflected to the user through the master robot during the phantom experiment. This system can drastically reduce radiation exposure by replacing human effort by a robotic system for high radiation exposure procedures. Also, benefits of the proposed robot system are low cost by employing currently available devices and easy human interface.
Vascular intervention involves inserting a catheter and guidewire into blood vessels to diagnose and treat a disease in an X-ray environment. In this conventional vascular intervention procedure, the doctor is exposed to considerable radiation. To reduce the exposure, we developed a master–slave robot system. A steerable catheter is employed to shorten the task-time and reduce the contact force applied to the vessel walls during catheter insertion. The steerable catheter helps to select a vascular branch; thus, the radiation exposure time for patients is reduced, and perforation in the patient’s vessel is prevented. Additionally, the robot system employs a haptic function to replicate the physician’s tactile sensing in vascular intervention. In this study, the effectiveness of the steering catheter and haptic function was demonstrated experimentally in comparison with a conventional catheter.
The development of a reliable pick-and-place system for industrial robotics is facing an urgent demand because many manual-labor works, such as piece-picking in warehouses and fulfillment centers tend toward automation. This paper presents an integrated gripper that combines a linkage-driven underactuated gripper with a suction gripping system for picking up a variety of objects in different working environments. The underactuated gripper consists of two fingers, and each finger has three degrees of freedom that are obtained by stacking one five-bar mechanism over one double parallelogram. Furthermore, each finger is actuated by two motors, both of which can be installed at the base owing to the special architecture of the proposed robotic finger. A suction cup is used to grasp objects in narrow spaces and cluttered environments. The combination of the suction and traditional linkage-driven grippers allows stable and reliable grasping under different working environments. Finally, practical experiments using a wide range of objects and under different grasping scenarios are performed to demonstrate the grasping capability of the integrated gripper.
1 August 2005 in Journal of Mechanical Science and Technology