Alexander Jahnke

Dr. Alexander Jahnke

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of Biomechanics
Verified
Journal Article
Closed access
IOIrina Oswald
Irina Oswald
MRMarkus Rickert
Markus Rickert
GBGert-Peter Brüggemann
Gert-Peter Brüggemann
ANAnja Niehoff
Anja Niehoff
CUCarlos Alfonso Fonseca Ulloa
Carlos Alfonso Fonseca Ulloa
AJAlexander Jahnke
Alexander Jahnke

14 August 2015 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
AJAlexander Jahnke
Alexander Jahnke
SESandra Engl
Sandra Engl
JSJörn Bengt Seeger
Jörn Bengt Seeger
EBErhan Basad
Erhan Basad
MRMarkus Rickert
Markus Rickert
BIBernd Alexander Ishaque
Bernd Alexander Ishaque

1 February 2018 in Clinical Biomechanics
Verified
Journal Article
Closed access
AJAlexander Jahnke
Alexander Jahnke
CUCarlos A. Fonseca Ulloa
Carlos A. Fonseca Ulloa
JSJörn Bengt Seeger
Jörn Bengt Seeger
MRMarkus Rickert
Markus Rickert
GJGerhard Walter Jahnke
Gerhard Walter Jahnke
BIBernd Alexander Ishaque
Bernd Alexander Ishaque

19 March 2019 in Medical Engineering & Physics
Verified
Journal Article
Closed access
AJAlexander Jahnke
Alexander Jahnke
CBCatharina Chiara Bott
Catharina Chiara Bott
CUCarlos Alfonso Fonseca Ulloa
Carlos Alfonso Fonseca Ulloa
GJGerhard Walter Jahnke
Gerhard Walter Jahnke
MRMarkus Rickert
Markus Rickert
GAGafar Adam Ahmed
Gafar Adam Ahmed
For preclinical statements about the anchoring behavior of prostheses, the primary stability of the prosthesis is of special importance. It was the aim of this study to examine and compare the relevant relative micromotions of three different acetabulum prostheses by introducing three-dimensional torques. The cups were implanted under standard conditions into an anatomical artificial bone model. Three-dimensional torques were applied to the acetabular cups. Taking into account the resulting frictional moments of two different bearing couples, ceramic-on-ceramic and ceramic-on-polyethylene, the relative micromotions of the cups were recorded as maximum total micromotion, translational and rotational micromotion, and the primary stability values of the three cups were compared. Relative micromotion of all cup models was always significantly smaller with the CoC bearing couples than with the CoP bearing couples (p < 0.001). The rotational micromotion was always lower (p < 0.001) than the translational micromotion, and the rotational as well as the translational micromotions were each always lower than the maximum total micromotion (p < 0.001, p < 0.010). The thinnest-walled cup system always showed the largest relative micromotions. The results of our study can be interpreted as indicating that the low relative micromotions of all cups - irrespective of the use of CoC or CoP bearing couples - are within an acceptable range favoring secondary osseointegration of the implants. Furthermore, we were able to show that the cup wall thickness and the surface quality of the cup systems have an influence on the primary stability and the elastic deformability of the examined cup systems.

11 July 2022 in Journal of Orthopaedics
Verified
Journal Article
Closed access
FKFlorian Kuhn
Florian Kuhn
RCRasmus Johannes Clausing
Rasmus Johannes Clausing
ASAlexander Stiller
Alexander Stiller
CUCarlos Alfonso Fonseca Ulloa
Carlos Alfonso Fonseca Ulloa
CFChristian Foelsch
Christian Foelsch
AJAlexander Jahnke
Alexander Jahnke

1 October 2018 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
AJAlexander Jahnke
Alexander Jahnke
SSStefan Schroeder
Stefan Schroeder
CUCarlos A. Fonseca Ulloa
Carlos A. Fonseca Ulloa
GAGafar A. Ahmed
Gafar A. Ahmed
BIBernd A. Ishaque
Bernd A. Ishaque
MRMarkus Rickert
Markus Rickert