Rachel B. Ger

Dr. Rachel B. Ger

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RGRachel B. Ger
Rachel B. Ger
Shouhao ZhouShouhao Zhou
Shouhao Zhou
PCPai-Chun Melinda Chi
Pai-Chun Melinda Chi
HLHannah J. Lee
Hannah J. Lee
RLRick Layman
Rick Layman
DMDennis Mackin
Dennis Mackin
Radiomics has shown promise in improving models for predicting patient outcomes. However, to maximize the information gain of the radiomics features, especially in larger patient cohorts, the variability in radiomics features owing to differences between scanners and scanning protocols must be accounted for. To this aim, the imaging variability of radiomics feature values was evaluated on 100 computed tomography scanners at 35 clinics by imaging a radiomics phantom using a controlled protocol and the commonly used chest and head protocols of the local clinic. We used a linear mixed-effects model to determine the degree to which the manufacturer and individual scanners contribute to the overall variability. Using a controlled protocol reduced the overall variability by 57% and 52% compared to the local chest and head protocols respectively. The controlled protocol also reduced the relative contribution of the manufacturer to the total variability. For almost all variabilities (manufacturer, scanner, and residual with different preprocesssing), the controlled protocol scans had a significantly smaller variability than the local protocol scans did. For most radiomics features, the imaging variability was small relative to the inter-patient feature variability in non–small cell lung cancer and head and neck squamous cell carcinoma patient cohorts. From this study, we conclude that using controlled scans can reduce the variability in radiomics features, and our results demonstrate the importance of using controlled protocols in prospective radiomics studies.

5 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DMDennis Mackin
Dennis Mackin
RGRachel B. Ger
Rachel B. Ger
CDCristina Dodge
Cristina Dodge
XFXenia Fave
Xenia Fave
PCPai-Chun Chi
Pai-Chun Chi
LCLaurence Edward Court
Laurence Edward Court
Variability in the x-ray tube current used in computed tomography may affect quantitative features extracted from the images. To investigate these effects, we scanned the Credence Cartridge Radiomics phantom 12 times, varying the tube current from 25 to 300 mA∙s while keeping the other acquisition parameters constant. For each of the scans, we extracted 48 radiomic features from the categories of intensity histogram (n = 10), gray-level run length matrix (n = 11), gray-level co-occurrence matrix (n = 22), and neighborhood gray tone difference matrix (n = 5). To gauge the size of the tube current effects, we scaled the features by the coefficient of variation of the corresponding features extracted from images of non-small cell lung cancer tumors. Variations in the tube current had more effect on features extracted from homogeneous materials (acrylic, sycamore wood) than from materials with more tissue-like textures (cork, rubber particles). Thirty-eight of the 48 features extracted from acrylic were affected by current reductions compared with only 2 of the 48 features extracted from rubber particles. These results indicate that variable x-ray tube current is unlikely to have a large effect on radiomic features extracted from computed tomography images of textured objects such as tumors.

17 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JLJoonsang Lee
Joonsang Lee
ASAngela Steinmann
Angela Steinmann
YDYao Ding
Yao Ding
HLHannah Lee
Hannah Lee
COConstance Owens
Constance Owens
LCLaurence Edward Court
Laurence Edward Court
Radiomics involves high-throughput extraction of large numbers of quantitative features from medical images and analysis of these features to predict patients’ outcome and support clinical decision-making. However, radiomics features are sensitive to several factors, including scanning protocols. The purpose of this study was to investigate the robustness of magnetic resonance imaging (MRI) radiomics features with various MRI scanning protocol parameters and scanners using an MRI radiomics phantom. The variability of the radiomics features with different scanning parameters and repeatability measured using a test–retest scheme were evaluated using the coefficient of variation and intraclass correlation coefficient (ICC) for both T1- and T2-weighted images. For variability measures, the features were categorized into three groups: large, intermediate, and small variation. For repeatability measures, the average T1- and T2-weighted image ICCs for the phantom (0.963 and 0.959, respectively) were higher than those for a healthy volunteer (0.856 and 0.849, respectively). Our results demonstrated that various radiomics features are dependent on different scanning parameters and scanners. The radiomics features with a low coefficient of variation and high ICC for both the phantom and volunteer can be considered good candidates for MRI radiomics studies. The results of this study will assist current and future MRI radiomics studies.

24 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Abdallah Sherif Radwan MohamedAbdallah Sherif Radwan Mohamed
Abdallah Sherif Radwan Mohamed
HEHesham Elhalawani
Hesham Elhalawani
AKAasheesh Kanwar
Aasheesh Kanwar
Abdallah Sherif Radwan MohamedAbdallah Sherif Radwan Mohamed
Abdallah Sherif Radwan Mohamed
AWAubrey White
Aubrey White
CFClifton David Fuller
Clifton David Fuller
Radiomics is one such “big data” approach that applies advanced image refining/data characterization algorithms to generate imaging features that can quantitatively classify tumor phenotypes in a non-invasive manner. We hypothesize that certain textural features of oropharyngeal cancer (OPC) primary tumors will have statistically significant correlations to patient outcomes such as local control. Patients from an IRB-approved database dispositioned to (chemo)radiotherapy for locally advanced OPC were included in this retrospective series. Pretreatment contrast CT scans were extracted and radiomics-based analysis of gross tumor volume of the primary disease (GTVp) were performed using imaging biomarker explorer (IBEX) software that runs in Matlab platform. Data set was randomly divided into a training dataset and test and tuning holdback dataset. Machine learning methods were applied to yield a radiomic signature consisting of features with minimal overlap and maximum prognostic significance. The radiomic signature was adapted to discriminate patients, in concordance with other key clinical prognosticators. 465 patients were available for analysis. A signature composed of 2 radiomic features from pre-therapy imaging was derived, based on the Intensity Direct and Neighbor Intensity Difference methods. Analysis of resultant groupings showed robust discrimination of recurrence probability and Kaplan-Meier-estimated local control rate (LCR) differences between “favorable” and “unfavorable” clusters were noted.

19 September 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RGRachel B. Ger
Rachel B. Ger
Shouhao ZhouShouhao Zhou
Shouhao Zhou
BEBaher Elgohari
Baher Elgohari
HEHesham Elhalawani
Hesham Elhalawani
DMDennis Mackin
Dennis Mackin
LCLaurence E. Court
Laurence E. Court
Radiomics studies require many patients in order to power them, thus patients are often combined from different institutions and using different imaging protocols. Various studies have shown that imaging protocols affect radiomics feature values. We examined whether using data from cohorts with controlled imaging protocols improved patient outcome models. We retrospectively reviewed 726 CT and 686 PET images from head and neck cancer patients, who were divided into training or independent testing cohorts. For each patient, radiomics features with different preprocessing were calculated and two clinical variables—HPV status and tumor volume—were also included. A Cox proportional hazards model was built on the training data by using bootstrapped Lasso regression to predict overall survival. The effect of controlled imaging protocols on model performance was evaluated by subsetting the original training and independent testing cohorts to include only patients whose images were obtained using the same imaging protocol and vendor. Tumor volume, HPV status, and two radiomics covariates were selected for the CT model, resulting in an AUC of 0.72. However, volume alone produced a higher AUC, whereas adding radiomics features reduced the AUC. HPV status and one radiomics feature were selected as covariates for the PET model, resulting in an AUC of 0.59, but neither covariate was significantly associated with survival. Limiting the training and independent testing to patients with the same imaging protocol reduced the AUC for CT patients to 0.55, and no covariates were selected for PET patients. Radiomics features were not consistently associated with survival in CT or PET images of head and neck patients, even within patients with the same imaging protocol.

1 November 2018 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
RGRachel B. Ger
Rachel B. Ger
DCDaniel F. Craft
Daniel F. Craft
DMDennis Mackin
Dennis Mackin
Shouhao ZhouShouhao Zhou
Shouhao Zhou
RLRick Layman
Rick Layman
LCLaurence Edward Court
Laurence Edward Court