Minal Jain

Dr. Minal Jain

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

19 November 2019 in Neurology
Verified
Journal Article
Closed access
PDF file
MJMinal Jain
Minal Jain
KMKatherine Meilleur
Katherine Meilleur
EKEunhee Kim
Eunhee Kim
GNGina Norato
Gina Norato
MWMelissa Waite
Melissa Waite
CBCarsten G. Bönnemann
Carsten G. Bönnemann
Objective To identify the rate of change of clinical outcome measures in children with 2 types of congenital muscular dystrophy (CMD), COL6-related dystrophies (COL6-RDs) and LAMA2-related dystrophies (LAMA2-RDs). Methods Over the course of 4 years, 47 individuals (23 with COL6-RD and 24 with LAMA2-RD) 4 to 22 years of age were evaluated. Assessments included the Motor Function Measure 32 (MFM32), myometry (knee flexors and extensors, elbow flexors and extensors), goniometry (knee and elbow extension), pulmonary function tests, and quality-of-life measures. Separate linear mixed-effects models were fitted for each outcome measurement, with subject-specific random intercepts. Results Total MFM32 scores for COL6-RDs and LAMA2-RDs decreased at a rate of 4.01 and 2.60 points, respectively, each year (p < 0.01). All muscle groups except elbow flexors for individuals with COL6-RDs decreased in strength between 1.70% (p < 0.05) and 2.55% (p < 0.01). Range-of-motion measurements decreased by 3.21° (p < 0.05) at the left elbow each year in individuals with LAMA2-RDs and 2.35° (p < 0.01) in right knee extension each year in individuals with COL6-RDs. Pulmonary function demonstrated a yearly decline in sitting forced vital capacity percent predicted of 3.03% (p < 0.01) in individuals with COL6-RDs. There was no significant change in quality-of-life measures analyzed. Conclusion Results of this study describe the rate of change of motor function as measured by the MFM32, muscle strength, range of motion, and pulmonary function in individuals with COL6-RDs and LAMA2-RDs.

3 July 2018 in Orphanet Journal of Rare Diseases
Verified
Journal Article
Open access
PDF file
JWJessica W. Witherspoon
Jessica W. Witherspoon
RVRuhi P. Vasavada
Ruhi P. Vasavada
MWMelissa R. Waite
Melissa R. Waite
MSMonique Shelton
Monique Shelton
ICIrene C. Chrismer
Irene C. Chrismer
KMKatherine G. Meilleur
Katherine G. Meilleur
RYR1-related Myopathies (RYR1-RM) comprise a group of rare neuromuscular diseases (NMDs) occurring in approximately 1/90000 people in the US pediatric population. RYR1-RM result from pathogenic mutations in the ryanodine receptor isoform-1 (RYR1) gene where consequent RyR1 protein calcium dysregulation leads to impaired excitation-contraction coupling, oxidative and nitrosative stress, and mitochondrial depletion. These physiological deficits perpetuate RyR1 dysfunction causing further muscle injury, muscle weakness, and muscle fatigue. Muscle weakness and fatigue are two primary complaints in patients with RYR1-RM and are major symptoms that limit the ability of individuals to perform activities of daily living. The six-minute walk test (6MWT) is an endurance test with high reliability and validity used to measure walking capacity, disease progression, and more recently, fatigability in NMDs with limited results in RYR1-RM. Therefore, the purpose of our study is to objectively assess disease progression and fatigability in RYR1-RM affected individuals using the 6MWT. We hypothesized that 6MWT distance and fatigability would not change significantly between 0 and 6-month visits in RYR1-RM patients, given the clinically reported stable or slowly progressive nature of the disease. We also hypothesized participants would show fatigability during the 6MWT, given muscle weakness and fatigue are the two primary complaints of affected individuals. As expected, paired t-test analyses revealed no significant difference between total distance traveled (p = .608) or percent change in speed (p = .141) at 0-months compared with the 6-month visit. Fatigability was observed given the decline in speed between the first and last minute of the 6MWT at the 6-month time point (p ≤ .0005,). Although this decline was not significant at baseline, a significant decline in speed from the 1st minute did occur at minutes 2, 3, and 4 during the baseline visit. In this RYR1-RM cohort, the 6MWT showed disease stability over a 6-month period but revealed fatigability during the test. Given these results, the 6MWT may be a promising endpoint for evaluating fatigability and therapeutic efficacy in the 6-month treatment phase of our current n-acetylcysteine trial in this population. Improvement post intervention could be attributed to the intervention rather than variability in disease progression. Clinical Trials.gov, NCT02362425 , Registered 13 February 2015-Prospectively registered.

1 September 2020 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Closed access
PDF file
VSVincent Shieh
Vincent Shieh
Ashwini SansareAshwini Sansare
Ashwini Sansare
MJMinal Jain
Minal Jain
TBThomas Bulea
Thomas Bulea
MMMartina Mancini
Martina Mancini
CZCris Zampieri
Cris Zampieri
Aims: Clinical evaluation of balance has relied on forceplate systems as the gold standard for postural sway measures. Recently, systems based on wireless inertial sensors have been explored, mostly in the adult population, as an alternative given their practicality and lower cost. Our goal was to validate body-worn sensors against forceplate balance measures in typically developing children during tests of quiet stance. Methods: 18 participants (8 males) 7 to 17 years old performed a quiet stance test standing on a forceplate while wearing 3 inertial sensors. Three 30-second trials were performed under 4 conditions: firm surface with eyes open and closed, and foam surface with eyes open and closed. Sway area, path length, and sway velocity were calculated. Results: We found 20 significant and 8 non-significant correlations. Variables found to be significant were represented across all conditions, except for the foam eyes closed condition. Conclusions: These results support the validity of wearable sensors in measuring postural sway in children. Inertial sensors may represent a viable alternative to the gold standard forceplate to test static balance in children.