Background. Water supplies can be contaminated by anthropogenic activities. The poultry industry uses a variety of heavy metals as additives in chicken feed, but excretion, runoff and dumping of he...
The aim of this research is to investigate the effect of long-term storage conditions on the physicochemical and microbial quality of selected sachet water brands sold within the Samaru community and its health implication for consumers. Three brands of sachet water were subjected to different storage conditions and were analyzed for microbial and physicochemical parameters at intervals of 3 weeks for a period of 3 months, based on procedures and standard methods of APHA (2005). The highest pH means concentration was recorded in sachet water samples used for control (7.14 ± 0.24) while EC, TDS, BOD, and calcium (336.67 ± 73.69 µS/cm, 168.33 ± 34.89 mg/L, 1.87 ± 0.39 mg/L and 2.97 ± 0.19 mg/L) were recorded in the sachet water samples stored on the floor. A total number of 15 fungal species and 4 bacteria species were identified from the three selected brands of sachet water examined. Aspergillus niger and Penicillium spp. have the highest species occurrence of 25% among the fungus identified while Proteus Sp. recorded the highest species occurrence (50%) among the bacteria isolated. Sachet water samples stored on the floor have the highest abundances of microbial species of five and six. All the physicochemical parameters were within the stipulated limits set by the World Health Organization and the Nigeria Standard for Drinking Water Quality, but fail microbial tests due to the presence of pathogens such as Aspergillus, Candida, Vibro, Yersinia, etc., that can cause a wide range of life-threatening system infections in a patient with mild immune-deficiency. Being under prolonged storage and the type of storage conditions can encourage the regrowth of microbial in packaged water under favorable environmental conditions, to levels that may be harmful to humans.
This study assessed the bacteriological quality of raw, treated, and distributed water from Ede-Erinle and Opa reservoirs in Osun State, Nigeria. This was to determine the potability of water from these waterwork stations. Eighteen sampling points were established across the two reservoir networks for this study. Samples were collected bi-monthly for two annual cycles. Serial dilution and pour plate methods were employed for the enumeration of bacterial load. Total heterotrophic bacteria count (THBC) and total coliform bacteria count (TCBC) were enumerated on nutrient and MacConkey agar at 37 °C, respectively. Bacterial isolates were characterized using biochemical identification methods with reference to Bergey's Manual of Determinative Bacteriology. Bacterial isolates and biofilm formation were further identified molecularly through the PCR method using specific universal primers. Mean values of THBC and TCBC in distributed water from Ede-Erinle (9.61 × 104 ± 1.50 × 104 CFU/mL; 69.56 ± 26.81 CFU/mL) and Opa waterworks (9.58 × 104 ± 2.55 × 104 CFU/mL; 142.94 ± 44.41 CFU/mL) exceeded permissible limits for drinking water. Paenibacillus lautus, Bacillus pseudomycoides, Pseudomonas aeruginosa, and Pseudomonas stutzeri showed biofilm-forming capacity. The study concluded that the presence of coliforms and biofilm-forming bacteria in distributed water implies that the water is unfit for consumption without further treatment.