Local field potential (LFP) recordings from deep brain stimulation (DBS) electrodes are often contaminated with electrocardiographic (ECG) artifacts that hinder the detection of disease-specific electrical brain activity. Three ECG suppression methods were evaluated: (1) QRS interpolation of the Perceive toolbox, (2) template subtraction, and (3) singular value decomposition (SVD). LFPs were recorded with the Medtronic PerceptTM PC system in nine Parkinson's disease patients with stimulation OFF ("OFF-DBS"; anode disconnected) and ON at 0 mA ("ON-DBS 0 mA"; anode connected). Findings were verified with simulated ECG-contaminated time series. ECG artifacts were present in 10 out of 18 ON-DBS 0 mA recordings. All ECG suppression methods drastically reduced artifact-induced beta band (13-35 Hz) power and at least partly recovered the beta peak and beta burst dynamics. Using external ECG recordings and lengthening artifact epoch length improved the performance of the suppression methods. Increasing epoch length, however, elevated the risk of flattening the beta peak and losing beta burst dynamics. The SVD method formed the preferred trade-off between artifact cleaning and signal loss, as long as its parameter settings are adequately chosen. ECG suppression methods enable analysis of disease-specific neural activity from signals affected by ECG artifacts.
14 June 2023 in Movement Disorders Clinical Practice
Essential tremor (ET) is one of the most common movement disorders, and continuous deep brain stimulation (DBS) is an established treatment for medication-refractory cases. However, the need for increasing stimulation intensities, with unpleasant side effects, and DBS tolerance over time can be problematic. The advent of novel DBS devices now provides the opportunity to longitudinally record LFPs using the implanted pulse generator, which opens up possibilities to implement adaptive DBS algorithms in a real-life setting. Here we report a case of thalamic LFP activity recorded using a commercially available sensing-enabled DBS pulse generator (Medtronic Percept PC). In the OFF-stimulation condition, a peak tremor frequency of 3.8 Hz was identified during tremor evoking movements as assessed by video and accelerometers. Activity at the same and supraharmonic frequency was seen in the frequency spectrum of the LFP data from the left vim nucleus during motor tasks. Coherence analysis showed that peripherally recorded tremor was coherent with the LFP signal at the tremor frequency and supraharmonic frequency. This is the first report of recorded tremor-related thalamic activity using the electrodes and pulse generator of an implanted DBS system. Larger studies are needed to evaluate the clinical potential of these fully implantable systems, and ultimately pulse generators with sensing-coupled algorithms driving stimulation, to really close the loop.
2 May 2022 in Movement Disorders Clinical Practice
Background: The presence and prevalence of several neurological signs in patients with primary orthostatic tremor have not been systematically studied.Objectives: To assess the prevalence of clinical features of primary orthostatic tremor.Methods: Video‐based assessment by four raters of standardized neurological examination of 11 patients with primary orthostatic tremor.Results: On standing, bent knees (7/11), hem sign (6/10), and a broad base of support (6/11) were the three most prevalent signs. Examination of gait revealed abnormal tandem gait (9/11) and bent knees (6/11) as the most prevalent clinical signs. In the arms, none of the patients displayed bradykinesia, ataxia, or dystonia. In the legs, ataxia was absent in all patients and bradykinesia was present in only one patient.Conclusions: Abnormal tandem gait, bent knees, hem sign, and broad base on standing are the most prevalent clinical signs in primary orthostatic tremor. We did not encounter clear extrapyramidal or unequivocal cerebellar signs.