Johanna Carina Thunberg

Ms. Johanna Carina Thunberg

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Studies in Conservation
Verified
Journal Article
Closed access
JTJohanna Carina Thunberg
Johanna Carina Thunberg
DWDavid Watkinson
David Watkinson
NENicola Emmerson
Nicola Emmerson
Since the early 1970s, archaeologists, conservators, and curators have turned to published guidance for methods of safeguarding archaeological metals in the short and long term. Much of this has appeared in editions of the ubiquitous handbook First Aid for Finds, the most recent of which dates to 1998. A central message across all guidance has been to dry metals post-excavation and prevent their corrosion during storage by desiccating the environment around them. This has been proven crucial for iron, with reports of catastrophic loss of collections arising from inappropriate storage environments. There has long been agreement that an effective, low cost option for desiccation is the packing of artefacts in boxes with a desiccant. Though advice on the details of how to achieve this has evolved over time, what has not changed is the lack of quantified evidence for the methods proposed. Informed by a survey of current practice in the sector, this study investigated quantitatively the many variables involved in creating desiccated microclimates for storage of heritage metals. This paper presents the results of an evaluation of the airtightness of a range of commercially available boxes, the optimum mass of desiccant, the effect of external environments, and preliminary data on the efficiency and risk of drying damp objects with silica gel. A second paper will report the effect of stacking boxes on their airtightness and present data on the accuracy and long-term reliability of humidity indicator cards. The guidance arising from laboratory testing of the hardware and methods for desiccated storage is designed to be achievable and adaptable. Combining these findings with corrosion rate data for iron artefacts allows the escalation of risk to objects from decisions in the storage process to be calculated. Together, these papers offer an evidence-based and practice-focused update to First Aid for Finds.

28 August 2025 in Heritage
Verified
Journal Article
Open access
PDF file
JTJohanna Carina Thunberg
Johanna Carina Thunberg
NENicola Emmerson
Nicola Emmerson
DWDavid Watkinson
David Watkinson
A key goal when managing copper alloy heritage is preventing “bronze disease,” which damages surface detail and may disintegrate objects by oxidation and hydrolysis of nantokite (CuCl), forming voluminous copper trihydroxychlorides (Cu2(OH)3Cl). The success of mitigation strategies is difficult to evaluate due to the complexity of copper alloy corrosion profiles, limitations in non-destructive analytical methods and incomplete understanding of the corrosion mechanisms and reactions involved in bronze disease. Without better understanding, it is impossible to design truly effective solutions for the safe storage and display of archaeological copper alloys. Advancing current understanding, this paper examines oxidation and hydrolysis of CuCl using oxygen consumption, Fourier transform infrared spectroscopy and Raman spectroscopy, recognised as the basis of bronze disease. Variables potentially affecting bronze disease processes are evaluated, including relative humidity (RH) (15–80%RH at 20 °C) and the presence of metallic copper with CuCl and their respective ratios. Results confirm that these variables influence the reaction mechanisms and kinetics of bronze disease. The rate of oxidation and hydrolysis of CuCl accelerates with RH, and its effect is quantified. The presence of copper is shown to be important for producing bronze disease; it facilitates a cyclic reaction forming Cu2(OH)3Cl, increases its formation rate at lower RH than by hydrolysis of CuCl alone and prevents formation of soluble chloride compounds. The formation of Cu2(OH)3Cl without counteracting copper ions is shown to promote formation of CuCl2 and CuCl2·2H2O, accelerating bronze disease. This new understanding is used to better quantify risk of bronze disease as a function of RH, providing a more quantitative tool for managing preservation of archaeological copper alloy collections.

21 June 2025 in Heritage
Verified
Journal Article
Open access
PDF file
JTJohanna Carina Thunberg
Johanna Carina Thunberg
NENicola Emmerson
Nicola Emmerson
DWDavid Watkinson
David Watkinson
Desiccated microclimates offer an effective method of managing safe storage of archaeological metals. They utilise simple hardware that can produce low relative humidity (RH) environments on a small scale to control post-excavation change in objects. Previous studies have highlighted the complexity of decision-making when setting up desiccated microclimates involving many factors that can impact on their performance. These include the design of the container used to house the microclimate, the ambient external atmosphere, the target internal RH, the amount of silica gel used and its regeneration schedule. This paper builds on that understanding by replicating reported sector-wide variations in how silica gel is used within desiccated microclimates. The desiccation efficacy, rate of change in RH and response to short-term fluctuations have been examined by monitoring the RH in polypropylene containers when silica gel is used loose, in polythene bags and Tyvek® bags. The effect of variables in the use of polythene bags to hold silica gel, including the distribution of bags and the number and size of holes in bags has also been investigated. Results indicate that these variables impact rates of change in RH and how effective the desiccated microclimate is at buffering external RH fluctuations. All tests reinforce the importance of airflow between the silica gel and the microclimate. Where airflow is restricted, the ability of the microclimate to desiccate the environment below lowest known corrosion thresholds (15% RH) is compromised. The practical implications of the results have been discussed to support decision-making and guidance is offered on best practice.